Effects of vibration characteristics on the walking discomfort of floating floors on concrete slabs

被引:5
|
作者
Kim, Jae Ho [1 ]
Jeon, Jin Yong [1 ]
机构
[1] Hanyang Univ, Dept Architectural Engn, Seoul 133791, South Korea
来源
关键词
SERVICEABILITY; PERCEPTION;
D O I
10.1121/1.4894686
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the present study, the vibration characteristics of floating floor systems and the discomfort in walking upon them have been studied in concrete slab structures through mock-up floors experiments. Seven types of floor systems, with panels of various sizes and supporting beams with different joist spacings, were constructed based on actual conditions. For the vibration measurement, an ISO rubber ball dropped from a height of 20 cm was used as an impact source to reproduce human walking. The vibration characteristics were evaluated by calculating the vibration acceleration values and the autocorrelation function parameters for the floor structures. Finally, a human walking experiment was conducted to investigate subjective responses to the vibration characteristics of floating floors. From the results, it was found that the vibration acceleration values and walking discomfort varied with the supporting conditions of the floors and that these were highly correlated with each other. It was also found that more than 75% of subjects accepted the floors when the vibration value of the floor in terms of vibration does value (VDV) is below 4.8 ms(-1.75). In addition, a practical regression of the VDV was obtained and design guidelines for floating floors were suggested. (C) 2014 Acoustical Society of America.
引用
收藏
页码:1702 / 1711
页数:10
相关论文
共 50 条
  • [2] VIBRATION ISOLATION ON FLOATING FLOORS
    NELSON, PA
    APPLIED ACOUSTICS, 1982, 15 (02) : 97 - 109
  • [3] Prestressed concrete slabs and grid floors - A CAD approach
    Raijiwala, DB
    Tamakuwala, PR
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON COMPUTING IN CIVIL AND BUILDING ENGINEERING, VOLS 1-4, 1997, : 739 - 744
  • [4] Vibration of precast prestressed concrete floors
    Mast, RF
    PCI JOURNAL, 2001, 46 (06): : 76 - 86
  • [5] Experimental and numerical investigations on vibration performance of mass timber slab floors with floating concrete toppings
    Guo, Chenyue
    Zhou, Jianhui
    Chui, Ying Hei
    ENGINEERING STRUCTURES, 2025, 330
  • [6] HUMAN RESPONSE TO WALKING AND IMPACT VIBRATION OF WOOD FLOORS
    ATHERTON, GH
    POLENSEK, A
    CORDER, SE
    FOREST PRODUCTS JOURNAL, 1976, 26 (10) : 40 - 47
  • [7] Vibration characteristics of closed profiled steel sheeting-concrete composite slabs
    College of Civil Engineering, Huaqiao University, Quanzhou 362021, China
    不详
    不详
    Harbin Gongye Daxue Xuebao, 2007, SUPPL. 2 (228-231):
  • [8] Minimum thickness of solid concrete floor slab with column line beams to avoid walking vibration discomfort
    Zahid, Tazwar Bakhtiyar
    Amanat, Khan Mahmud
    STRUCTURAL CONCRETE, 2022, 23 (06) : 3511 - 3520
  • [9] Parametric study on the vibration sensitivity of hollow-core slabs floors
    Marcos, Lara Kawai
    Carrazedo, Ricardo
    EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 1095 - 1102
  • [10] HUMAN RESPONSE TO WALKING AND IMPACT VIBRATION OF WOOD FLOORS.
    Atherton, George H.
    Polensek, Anton
    Corder, Stanley E.
    1600, (26):