Design of beam shaping assembly based on 3.5 MeV radio-frequency quadrupole proton accelerator for boron neutron capture therapy

被引:6
|
作者
Tian Yong-Shun [1 ,2 ,3 ]
Hu Zhi-Liang [2 ,3 ]
Tong Jian-Fei [2 ,3 ]
Chen Jun-Yang [2 ,3 ]
Peng Xiang-Yang [1 ]
Liang Tian-Jiao [2 ,3 ]
机构
[1] Xiangtan Univ, Sch Phys & Optoelect, Xiangtan 411105, Peoples R China
[2] Dongguan Neutron Sci Ctr, Dongguan 523803, Peoples R China
[3] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
关键词
noron neutron capture therapy; Monte Carlo simulation; beam shaping assembly; moderator; BRAIN TUMORS; BNCT;
D O I
10.7498/aps.67.20180380
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Boron neutron capture therapy (BNCT) is expected to be an effective method of improving the treatment results on malignant brain glioma and malignant melanoma, for which no successful treatment has been developed so far. The beam shaping assembly (BSA) of accelerator-based boron neutron capture therapy (A-BNCT) consists of a moderator, a reflector, gamma and thermal neutron shielding and a collimator. The BSA moderates the fast neutron produced in target to epithermal energy range. Design of BSA is one of the key jobs in BNCT project. An optimized study was conducted to design a beam shaping assembly for BNCT facility based on 3.5 MeV 10 mA radio-frequency quadrupole proton accelerator at Dongguan Neutron Science Center. In this simulation work, the neutron produced from the Li-7 (p, n) Be-7 reaction by 3.5 MeV proton is adopted as a neutron source term. In order to search for an optimized beam shaping assembly for accelerator-based BNCT, Monte Carlo simulation is carried out based on the parameters of moderator material and structure, the Gamma shielding, and the thermal neutron filter in the beam shaping assembly. The beam shaping assembly in this work consists of various moderator materials, teflon as reflector, Bi as gamma shielding, Li-6 as thermal neutron filter, and lithium polyethylene as collimator. After comparing the simulation results of Fluental and LiF moderator materials, the beam shaping assembly configuration based on sandwich Fluental-LiF configuration is proposed. The sandwich Fluental-LiF configuration is made up of Fluental and LiF layer by layer, like a sandwich structure, and each layer is 2 cm thick. According to the beam quality requirement of the IAEA-tecdoc-1223 report, the optimized epithermal neutron flux in air at the exit of BSA of the sandwich Fluental-LiF configuration is 9.14 x 10(8) n/(cm(2).s), which is greater than those of the Fluental configuration (7.81 x 10(8) n/(cm(2).s)) and LiF configuration (8.79 x 10(8) n/(cm(2).s)), when the ratio of fast neutron component to gamma ray component to thermal neutron is less than the limiting value of IAEA recommendation. Subsequently, the depth distribution of the equivalent doses in the Snyder head phantom is calculated to evaluate the treatment characteristic. The simulation results show that the therapy rate of the beam shaping assembly based on the sandwich Fluental-LiF configuration is basically equal to that of the Fluental configuration and better than that of the LiF configuration, and the therapy time is less than that of the Fluental configuration. This means that the beam shaping assembly based on the sandwich Fluental-LiF configuration is one of the suitable options for our accelerator-based BNCT.
引用
收藏
页数:8
相关论文
共 21 条
  • [1] Bleuel D L, 2003, THESIS
  • [2] Computational assessment of deep-seated tumor treatment capability of the 9Be(d,n)10B reaction for accelerator-based Boron Neutron Capture Therapy (AB-BNCT)
    Capoulat, M. E.
    Minsky, D. M.
    Kreiner, A. J.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (02): : 133 - 146
  • [3] Designing of the 14 MeV neutron moderator for BNCT
    Cheng Dao-Wen
    Lu Jing-Bin
    Yang Dong
    Liu Yu-Min
    Wang Hui-Dong
    Ma Ke-Yan
    [J]. CHINESE PHYSICS C, 2012, 36 (09) : 905 - 908
  • [4] CHOI JR, 1990, BASIC LIFE SCI, V54, P201
  • [5] DERIVATIONS OF RELATIVE BIOLOGICAL EFFECTIVENESS FOR THE HIGH-LET RADIATIONS PRODUCED DURING BORON NEUTRON-CAPTURE IRRADIATIONS OF THE 9L RAT GLIOSARCOMA IN-VITRO AND IN-VIVO
    CODERRE, JA
    MAKAR, MS
    MICCA, PL
    NAWROCKY, MM
    LIU, HYB
    JOEL, DD
    SLATKIN, DN
    AMOLS, HI
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05): : 1121 - 1129
  • [6] [关遐龄 Guan Xialing], 2003, [核科学与工程, Chinese Journal of Nuclear Science and Engineering], V23, P73
  • [7] Treatment planning capability assessment of a beam shaping assembly for accelerator-based BNCT
    Herrera, M. S.
    Gonzalez, S. J.
    Burlon, A. A.
    Minsky, D. M.
    Kreiner, A. J.
    [J]. APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1870 - 1873
  • [8] IAEA, 2001, CURR STT NEUTR CAPT, P7
  • [9] A Monte Carlo dosimetry-based evaluation of the 7Li(p, n)7Be reaction near threshold for accelerator boron neutron capture therapy
    Lee, CL
    Zhou, XL
    Kudchadker, RJ
    Harmon, F
    Harker, YD
    [J]. MEDICAL PHYSICS, 2000, 27 (01) : 192 - 202
  • [10] Locher GL, 1936, AM J ROENTGENOL RADI, V36, P1