Dynamic Flat field correction in X-ray computed tomography

被引:0
|
作者
Van Nieuwenhove, Vincent [1 ]
De Beenhouwer, Jan [1 ]
Marone, F. [2 ]
Mancini, L. [3 ]
Sijbers, Jan [1 ]
机构
[1] Univ Antwerp, iMinds Vis Lab, Univ Pl 1,Bldg N, B-2610 Antwerp, Belgium
[2] Paul Scherrer Inst, WBBA 216, CH-5232 Villigen, Switzerland
[3] Elettra Sincrotrone Trieste SCpA, SS 14 Km 163,5 Area Sci Pk, I-34149 Trieste, Italy
关键词
RECONSTRUCTIONS; DETECTORS;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In computed tomography (CT), X-ray projections are acquired from different angles, which are then used to reconstruct a 3D image. Prior to reconstruction, the projections have to be normalised with respect to a white field, which is generally referred to as Flat Field Correction (FFC). The white field is computed from projections acquired without object between the x-ray source and detector. Conventional FFC assumes the flat fields to be stationary. However, due to beam intensity changes, temperature fluctuations or detector efficiency fluctuations, dynamic changes are observed resulting in projections that are not properly FFC corrected. We propose an efficient procedure to model and correct for flat field dynamics. The dynamics of the flat fields are described by eigen flat fields, derived from a series of prior and/or post flat fields using Principal Components Analysis (PCA). A time dependent flat field can then be approximated by a linear combination of the mean flat field and a limited number of eigen flat fields (EFF). The weights of these EEF in a Xray projections are estimated by minimizing the total variation using a non-linear optimization algorithm. Results on synchrotron CT datasets show that the proposed technique results in projections with almost no artefacts due to flat field fluctuations. Furthermore, the reconstructions show reduced flat field induced artefacts.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 50 条
  • [1] Dynamic X-ray computed tomography
    Bonnet, S
    Koenig, A
    Roux, S
    Hugonnard, P
    Guillemaud, R
    Grangeat, P
    PROCEEDINGS OF THE IEEE, 2003, 91 (10) : 1574 - 1587
  • [2] Ring artifact correction for X-ray computed tomography
    Ma, Jiming
    Song, Yan
    Wang, Qunshu
    Song, Guzhou
    Zhang, Jianqi
    Xia, Jingtao
    Han, Changcai
    Duan, Baojun
    Du, Jiye
    Zhou, Ming
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (12):
  • [3] Dynamic angle selection in X-ray computed tomography
    Dabravolski, Andrei
    Batenburg, Kees Joost
    Sijbers, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 324 : 17 - 24
  • [4] Ring artefact eduction via multi-point piecewise linear flat field correction for X-ray computed tomography
    Lifton, Joseph
    Liu, Tong
    OPTICS EXPRESS, 2019, 27 (03): : 3217 - 3228
  • [5] X-ray flat-panel detector geometry correction to improve dimensional computed tomography measurements
    Luethi, Melina
    Bircher, Benjamin A.
    Meli, Felix
    Kueng, Alain
    Thalmann, Rudolf
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (03)
  • [6] Bronnikov-aided correction for x-ray computed tomography
    De Witte, Yoni
    Boone, Matthieu
    Vlassenbroeck, Jelle
    Dierick, Manuel
    Van Hoorebeke, Luc
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2009, 26 (04) : 890 - 894
  • [7] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [8] X-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [9] X-ray computed tomography
    Withers, Philip J.
    Bouman, Charles
    Carmignato, Simone
    Cnudde, Veerle
    Grimaldi, David
    Hagen, Charlotte K.
    Maire, Eric
    Manley, Marena
    Du Plessis, Anton
    Stock, Stuart R.
    NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [10] X-ray computed tomography
    Nature Reviews Methods Primers, 1