Real-Time Risk Score for GlaucomaMass Screening by Spectral Domain Optical Coherence Tomography: Development and Validation

被引:4
|
作者
Fukai, Kota [1 ]
Terauchi, Ryo [2 ]
Noro, Takahiko [2 ]
Ogawa, Shumpei [2 ]
Watanabe, Tomoyuki [2 ]
Nakagawa, Toru [3 ]
Honda, Toru [3 ]
Watanabe, Yuya [3 ]
Furuya, Yuko [1 ]
Hayashi, Takeshi [3 ]
Tatemichi, Masayuki [1 ]
Nakano, Tadashi [2 ]
机构
[1] Tokai Univ, Sch Med, Dept Prevent Med, Tokyo, Kanagawa, Japan
[2] Jikei Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
[3] Hitachi Hlth Care Ctr, Ibaraki, Japan
来源
基金
日本学术振兴会;
关键词
glaucoma; optical coherence tomography; mass screening; risk score; algorithms; NERVE-FIBER LAYER; MACULAR THICKNESS; TECHNOLOGY; PREVALENCE; DIAGNOSIS; PERFORMANCE; STRATUSOCT; ASYMMETRY; WORLDWIDE; PEOPLE;
D O I
10.1167/tvst.11.8.8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop and validate a risk score assessable in real-time using only retinal thickness-related values measured by spectral domain optical coherence tomography alone for use in population-based glaucoma mass screenings. Methods: A total of 7572 participants (aged 35-74 years) underwent spectral domain optical coherence tomography examination annually between 2016 to 2021 in a population-based setting. We selected 284 glaucoma cases and 284 controls, matched by age and sex, from 11,487 scans in 2016. We conducted multivariable logistic regression with backward stepwise selection of retinal thickness-related variables to develop the diagnosticmodels. The developed risk scoreswere applied to all participants in 2018 (9720 eyes), and we randomly selected 723 scans for validation. Additional validation using the Humphrey field analyzer was conducted on 129 eyes in 2020. We assessed the models using sensitivity, specificity, the area under the receiver operating characteristic curve and positive and negative predictive values. Results: The best-predicting model achieved an area under the receiver operating characteristic curve of 0.97 (95% confidence interval, 0.96-0.98) with a sensitivity of 0.93 and specificity of 0.91. The validation dataset showed a positive predictive value of 90.8% for high-risk scorers, corresponding to 6.2% of the population, and negative predictive value of 88.2% for low-risk scorers, corresponding to 85.2%. Sensitivity and specificity for glaucoma diagnosis were 0.85 and 0.91, when we set the risk score cut- off at 90 points out of 100. Conclusions: This risk score could be used as a valid index for glaucoma screening in a population-based setting. Translational Relevance: The score is feasible by installing a simple computer application on an existing spectral domain optical coherence tomography and will help to improve the accuracy and efficiency of glaucoma screening.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Real-time compressive sensing spectral domain optical coherence tomography
    Xu, Daguang
    Huang, Yong
    Kang, Jin U.
    OPTICS LETTERS, 2014, 39 (01) : 76 - 79
  • [2] Real-time intraoperative spectral domain optical coherence tomography for vitreoretinal surgery
    Tao, Yuankai K.
    Toth, Cynthia A.
    Izatt, Joseph A.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [3] Real-time monitoring of structural vibration using spectral-domain optical coherence tomography
    Zhong, Shuncong
    Shen, Hao
    Shen, Yaochun
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (01) : 127 - 131
  • [4] Three-Dimensional Real-Time Flow Visualization Using Spectral and Time Domain Optical Coherence Tomography
    Szkulmowski, M.
    Szlag, D.
    Orlowski, S.
    Sylwestrzak, M.
    Szkulmowska, A.
    Kowalczyk, A.
    Wojtkowski, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Real-time spectral domain Doppler optical coherence tomography and investigation of human retinal vessel autoregulation
    Bower, Bradley A.
    Zhao, Mingtao
    Zawadzki, Robert J.
    Izatt, Joseph A.
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (04)
  • [6] Imaging the eye fundus with real-time en-face spectral domain optical coherence tomography
    Bradu, Adrian
    Podoleanu, Adrian Gh
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (04): : 1233 - 1249
  • [7] Real-time Functional Analysis of Inertial Microfluidic Devices via Spectral Domain Optical Coherence Tomography
    Dong, Biqin
    Chen, Siyu
    Zhou, Fan
    Chan, Christina H. Y.
    Yi, Ji
    Zhang, Hao F.
    Sun, Cheng
    SCIENTIFIC REPORTS, 2016, 6
  • [8] Real-time Functional Analysis of Inertial Microfluidic Devices via Spectral Domain Optical Coherence Tomography
    Biqin Dong
    Siyu Chen
    Fan Zhou
    Christina H. Y. Chan
    Ji Yi
    Hao F. Zhang
    Cheng Sun
    Scientific Reports, 6
  • [9] Investigation of retinal vessel autoregulation using real-time spectral domain Doppler optical coherence tomography
    Bower, Bradley A.
    Zhao, Mingtao
    Izatt, Joseph A.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [10] Performance of time-domain and spectral-domain Optical Coherence Tomography for glaucoma screening
    Bengtsson, Boel
    Andersson, Sabina
    Heijl, Anders
    ACTA OPHTHALMOLOGICA, 2012, 90 (04) : 310 - 315