Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study

被引:22
|
作者
Gaudin, Gael [1 ]
Ferreira, Andre [2 ]
Gaillard, Romain [1 ]
Prudhon, Jean Louis [3 ]
Caton, Jacques H. [4 ]
Lustig, Sebastien [1 ]
机构
[1] Hop Croix Rousse, Ctr Albert Trillat, 103 Grande Rue Croix Rousse, F-69004 Lyon, France
[2] Clin Parc, 155 Ter Blvd Stalingrad, F-69006 Lyon, France
[3] Ctr Osteoarticulaire Cedres, 5 Rue Trop, F-38130 Echirolles, France
[4] Inst Orthoped, 103 Rue Coste, F-69300 Caluire Et Cuire, France
关键词
Dual mobility; Hip joint simulator; Total hip; arthroplasty; Wear; MOLECULAR-WEIGHT POLYETHYLENE; INTRA-PROSTHETIC DISLOCATION; FOLLOW-UP; PREVENT DISLOCATION; ACETABULAR LINERS; CROSS-LINKING; CUP; STERILIZATION; OSTEOLYSIS; STABILITY;
D O I
10.1007/s00264-016-3346-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Osteolysis in total hip arthroplasty (THA) depends on polyethylene wear and dictates the survival of the prosthesis. Dual mobility in THAs, which is claimed to reduce dislocation risk, has very good long-term clinical results. However, little is known about how the liner wears in this design, compared to the standard single mobility model. Methods A comparative study looking at wear of a conventional ultra-high-molecular-weight polyethylene liner, using gravimetric measurement, between dual mobility implants and standard implants, was performed on a simulator in accordance with a normed protocol based on the same dimensions, environmental conditions and stresses. A linear regression test was employed. Results Under the same conditions (loading, cycles, sterilization, material and surface roughness), the gravimetric wear (for conventional polyethylene) is comparable between a standard and a dual mobility cup. This correlates to ten year follow-up results of dual mobility cup. Discussion - Conclusion This in vitro equivalent wear serves to confirm the very good long-term clinical results observed with dual mobility bearing, whose use should not be restricted by concerns about increased polyethylene wear.
引用
收藏
页码:521 / 527
页数:7
相关论文
共 50 条
  • [1] Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study
    Gaël Gaudin
    André Ferreira
    Romain Gaillard
    Jean Louis Prudhon
    Jacques H. Caton
    Sébastien Lustig
    International Orthopaedics, 2017, 41 : 521 - 527
  • [2] Hip stability parameters with dual mobility, modular dual mobility and fixed bearing in total hip arthroplasty: an analytical evaluation
    Domenico Tigani
    Lorenzo Banci
    Riccardo Valtorta
    Luca Amendola
    BMC Musculoskeletal Disorders, 23
  • [3] Hip stability parameters with dual mobility, modular dual mobility and fixed bearing in total hip arthroplasty: an analytical evaluation
    Tigani, Domenico
    Banci, Lorenzo
    Valtorta, Riccardo
    Amendola, Luca
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [4] Bearing couples in total hip arthroplasty
    Tailor, Hiteshkumar
    Patel, Shelain
    Patel, Rahul V.
    Haddad, Fares S.
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2010, 71 (08) : 446 - 450
  • [5] Bearing Surfaces for Total Hip Arthroplasty
    Lachiewicz, Paul F.
    Kleeman, Lindsay T.
    Seyler, Thorsten
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2018, 26 (02) : 45 - 57
  • [6] Bearing selection in total hip arthroplasty
    Sonntag, R.
    Reinders, J.
    Mueller, U.
    Kretzer, J. P.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2015, 153 (06): : 587 - 596
  • [7] Dual Mobility Bearing Articulations Result in Lower Rates of Dislocation After Revision Total Hip Arthroplasty
    Li, William T.
    Kozick, Zachary
    Sherman, Matthew
    Restrepo, Camilo
    Smith, Eric B.
    Courtney, P. Maxwell
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (20) : 831 - 837
  • [8] Wear Performance Evaluation of a Contemporary Dual Mobility Hip Bearing Using Multiple Hip Simulator Testing Conditions
    Loving, LaQuawn
    Lee, Reginald KinFay
    Herrera, Lizeth
    Essner, Aaron Paul
    Nevelos, Jim Edward
    JOURNAL OF ARTHROPLASTY, 2013, 28 (06): : 1041 - 1046
  • [9] Anatomization of wear behaviour of materials for total hip arthroplasty bearing surfaces: A review
    Borah, Volga
    Bora, Uddipta
    Baishya, Utpal Jyoti
    Pegu, Boikuntha
    Sahai, Nitin
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 176 - 186
  • [10] Dual Mobility in Total Hip Arthroplasty
    Clair, Andrew J.
    Buchalter, Daniel B.
    Kugelman, David N.
    Deshmukh, Ajit J.
    Aggarwal, Vinay K.
    Rozell, Joshua C.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2022, 80 (01): : 4 - 10