THERMAL CHARACTERISTICS OF A HEAT EXCHANGER TUBE FITTED WITH DIFFERENT PERIPHERALLY-CUT TWISTED TAPE INSERTS IN LAMINAR FLOW

被引:0
|
作者
Zheng, Guowei [1 ]
Zhang, Wenbo [1 ]
Man, Changzhong [1 ]
Sun, Peiyan [1 ]
机构
[1] Dalian Univ Technol, Minist Educ, Key Lab Ocean Energy Utilizat & Energy Conservat, Dalian 116024, Peoples R China
关键词
heat transfer enhancement; clockwise and counterclockwise; twisted tape; peripherally-cut; laminar flow; FRICTION FACTOR CHARACTERISTICS; TRANSFER ENHANCEMENT; PERFORMANCE ASSESSMENT; CIRCULAR TUBE; SQUARE; AUGMENTATION;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental analyses of the alternation of clockwise and counterclockwise twisted tape (AT tape), and the AT tape in conjunction with three types of edge notches (V-cut, semicircle-cut, and rectangular-cut) on heat transfer and laminar flow friction characteristics in a uniform heat flux, circular copper tube using water as working fluid have been investigated in this paper. The investigations of plain tube were also carried out for comparison. The experiments covered a range of Reynolds numbers 500 <= Re <= 1800. The obtained results reveal that all of the present twisted tapes utilized in the experiment can significantly increase the Nusselt number and friction factor. The Nusselt number increases with increase in the Reynolds number while the friction factor shows an opposite trend for all cases. For a fixed Reynolds number, the Nusselt number and friction factor both increase with the reduction of edge notch area. Over the range investigated, the maximum value of performance evaluation criterion (PEC) achieved by the AT tape insert reached 1.54 at the Reynolds number equal to 1800. Finally, the empirical correlations for the Nusselt number, friction factor, and PEC were also determined. The predicted Nusselt number, friction factor, and PEC were, respectively, within +/- 6.1%, +/- 4.1%, and +/- 3.3% deviation compared to the experimental data.
引用
收藏
页码:29 / 42
页数:14
相关论文
共 50 条
  • [1] THERMAL CHARACTERISTICS OF A HEAT EXCHANGER TUBE FITTED WITH DIFFERENT PERIPHERALLY-CUT TWISTED TAPE INSERTS IN LAMINAR FLOW
    Zheng G.
    Zhang W.
    Man C.
    Sun P.
    Man, Changzhong (mcz640927@dlut.edu.cn), 1600, Begell House Inc. (52): : 29 - 42
  • [2] Thermal characteristics in a heat exchanger tube fitted with triple twisted tape inserts
    Bhuiya, M. M. K.
    Chowdhury, M. S. U.
    Shahabuddin, M.
    Saha, M.
    Memon, L. A.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 48 : 124 - 132
  • [3] Influences of peripherally-cut twisted tape insert on heat transfer and thermal performance characteristics in laminar and turbulent tube flows
    Eiamsa-ard, Smith
    Seemawute, Panida
    Wongcharee, Khwanchit
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (06) : 711 - 719
  • [4] Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes
    Changcharoen, W.
    Somravysin, P.
    Eiamsa-ard, S.
    OPEN ENGINEERING, 2015, 5 (01): : 89 - 98
  • [5] Heat Transfer Enhancement of Laminar Nanofluids Flow in a Circular Tube Fitted with Parabolic-Cut Twisted Tape Inserts
    Salman, Sami D.
    Kadhum, Abdul Amir H.
    Takriff, Mohd S.
    Mohamad, Abu Bakar
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [6] Performance investigation of laminar flow through tube fitted with hyperbolic-cut twisted tape inserts
    Rajan, Abhijit
    Prasad, Laljee
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021,
  • [7] Performance intensification analysis of laminar flow through heat exchanger tube with drumet-cut twisted tape inserts
    Shivesh Kumar
    Laljee Prasad
    Multiscale and Multidisciplinary Modeling, Experiments and Design, 2024, 7 : 1223 - 1235
  • [8] Performance intensification analysis of laminar flow through heat exchanger tube with drumet-cut twisted tape inserts
    Kumar, Shivesh
    Prasad, Laljee
    MULTISCALE AND MULTIDISCIPLINARY MODELING EXPERIMENTS AND DESIGN, 2024, 7 (02) : 1223 - 1235
  • [9] Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Eiamsa-ard, Petpices
    Promvonge, Pongjet
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (01) : 39 - 46
  • [10] Thermohydraulics of turbulent flow through a round tube by a peripherally-cut twisted tape with an alternate axis
    Seemawute, Panida
    Eiamsa-ard, Smith
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (06) : 652 - 659