Novel potentiometric monitoring combined with coulometric reagent generation

被引:3
|
作者
Nagy, G [1 ]
Toth, K [1 ]
Feher, Z [1 ]
Kunovits, J [1 ]
机构
[1] TECH UNIV BUDAPEST,INST GEN & ANALYT CHEM,HUNGARIAN ACAD SCI,RES GRP TECH ANALYT CHEM,H-1111 BUDAPEST,HUNGARY
关键词
potentiometry; coulometry; flow system;
D O I
10.1016/0003-2670(95)00470-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric monitor incorporating a flow-through analysis channel has been developed based on the standard addition or subtraction principle. Programmed addition of standard or reagent was carried out at a given point of the flow-through system by current-programmed coulometry. A computer was used for data acquisition, for electric noise rejection, for signal recognition and for calculating the analytical results. The characteristics of the monitor system have been investigated under conditions optimised for the chloride determination, and the performance of it was checked by monitoring the chloride concentration in tap water.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [1] ELECTROLYTIC SOLUTION FOR COULOMETRIC GENERATION OF REAGENT,KF
    MIYAKE, S
    SUTO, T
    JAPAN ANALYST, 1974, 23 (05): : 476 - 482
  • [2] A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection
    de Aquino, Emerson Vidal
    Rodrigues Rohwedder, Jarbas Jose
    Pasquini, Celio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (06) : 1921 - 1930
  • [3] A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection
    Emerson Vidal de Aquino
    Jarbas José Rodrigues Rohwedder
    Celio Pasquini
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1921 - 1930
  • [4] COULOMETRIC TRACE DETERMINATION OF WATER BY USING FISCHER,K REAGENT AND POTENTIOMETRIC ENDPOINT DETECTION
    CEDERGRE.A
    TALANTA, 1974, 21 (06) : 367 - 375
  • [5] A COMBINED POTENTIOMETRIC-COULOMETRIC METHOD FOR ANALYSIS OF URANIUM IN CARBONATE MEDIA
    FERRI, D
    SALVATORE, F
    VASCA, E
    MIRANDA, R
    ANNALI DI CHIMICA, 1994, 84 (7-8) : 283 - 293
  • [6] Potentiometric and coulometric determination of carbimazole
    Ciesielski, W
    Krenc, A
    ANALYTICAL LETTERS, 2000, 33 (08) : 1545 - 1554
  • [7] Electrochemical cell for potentiometric coulometric
    Ryasenskij, S.S.
    Gorelov, I.P.
    Baranov, A.N.
    Zavodskaya Laboratoriya. Diagnostika Materialov, 2003, 69 (09): : 20 - 22
  • [8] A coulometric flow cell for in-line generation of reagent, titrant or standard solutions
    Oliveira, SCB
    Coelho, ECS
    Selva, TMG
    Santos, FP
    Araújo, MCU
    Abreu, FC
    Nascimento, VB
    MICROCHEMICAL JOURNAL, 2006, 82 (02) : 220 - 225
  • [9] Universal coulometric nanotitrators with potentiometric detection
    Guenat, O. T.
    Morf, W. E.
    Van der Schoot, B. H.
    De Rooij, N. F.
    Analytica Chimica Acta, 361 (03):
  • [10] Universal coulometric nanotitrators with potentiometric detection
    Guenat, OT
    Morf, WE
    van der Schoot, BH
    de Rooij, NF
    ANALYTICA CHIMICA ACTA, 1998, 361 (03) : 261 - 272