Interest of a chemometric approach in understanding the retention behaviour of three columns in hydrophilic interaction liquid chromatography: Application to the separation of glycerol carbonate, glycerol and urea

被引:19
|
作者
Fourdinier, Marion [1 ]
Bostyn, Stephane [1 ]
Delepee, Raphael [1 ]
Fauduet, Henri [1 ]
机构
[1] Univ Orleans, CNRS, UMR 6005, ICOA,Inst Univ Technol, F-45067 Orleans 2, France
关键词
Hydrophilic interaction liquid; chromatography; Retention behaviour; Resolution; Mixture design; Desirability function; Glycerol; Urea; POLAR COMPOUNDS; SUGAR; MS;
D O I
10.1016/j.talanta.2010.02.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemometric approach was used to study the retention behaviour of glycerol, urea and glycerol carbonate in hydrophilic interaction liquid chromatography (HILIC) First, a simplex method was developed to optimize the sensitivity of an evaporative light scattering detector A mixture design was then applied to model retention factors as a function of the mobile phase content in acetonitrile, water and methanol on three columns Atlantis HILIC Silica, ZIC-HILIC and Monochrom diol. Atlantis HILIC Silica exhibits predominantly hydrophobic interactions, while retention on the other two columns is mainly ruled by hydiophilic interactions. Finally, a desirability function is applied on the resolution factors. The use of this function enables the compositions of eluent phases to be determined in order to achieve separation between the three chemicals. Monochrom diol proved to be the most efficient column. (C) 2010 Elsevier B.V All rights reserved