Airborne measurements of HCHO and HCOOH during the New England Air Quality Study 2004 using a pulsed quantum cascade laser spectrometer

被引:66
|
作者
Herndon, Scott C. [1 ]
Zahniser, Mark S.
Nelson, David D., Jr.
Shorter, Joanne
McManus, J. Barry
Jimenez, Rodrigo
Warneke, Carsten
de Gouw, Joost A.
机构
[1] Aerodyne Res Inc, Billerica, MA 01821 USA
[2] Harvard Univ, Dept Earth & Planetary Sci, Cambridge, MA 02138 USA
[3] NOAA, Earth Syst Res Lab, Boulder, CO 80303 USA
关键词
D O I
10.1029/2006JD007600
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Atmospheric mixing ratios of formaldehyde and formic acid have been measured from the NOAA WP-3 aircraft during the New England Air Quality Study (NEAQS) of July and August 2004 using a newly developed quantum cascade laser (QCL) spectrometer operating at a wavelength of 5.6 mm. The laser operates in pulsed mode with thermoelectric cooling. The detection is based on direct absorption in a compact 76-m multiple pass absorption cell. The laser is swept over a 0.5 cm(-1) spectral region containing multiple lines of both HCHO and HCOOH. Absolute concentrations are retrieved by simultaneous spectral fitting routines with a detection limit (2 sigma) for HCHO of 0.3 parts in 10 9 (ppbv) with an averaging time of 60 s under stable flight conditions. HCHO mixing ratios in the range from 0.3 to 5 ppb were encountered during flight conditions. Some of the highest mixing ratios of HCHO were observed over heavily vegetated areas of Florida during the test flights where the ratios of HCHO to methacrolein and methyl vinyl ketone, measured by proton transfer mass spectroscopy, are consistent with formaldehyde production by isoprene oxidation. The highest mixing ratios of HCOOH, up to 10 ppbv, were observed in an aged forest fire plume encountered over northern Canada, in which ratios of HCOOH/CO are greater than previous observations, while the ratios of HCHO/CO are less than previous reports from forest fire plumes. Observations of HCHO/CO and HCOOH/CO in urban plumes are indicative of a mixture of sources from direct emissions and secondary oxidation of anthropogenic and biogenic hydrocarbons. The ability to measure both HCHO and HCOOH simultaneously is of value in assessing the oxidation mechanisms of atmospheric hydrocarbons and secondary organic aerosol formation and oxidation.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Sulfur dioxide emission flux measurements from point sources using airborne near ultraviolet spectroscopy during the New England Air Quality Study 2004
    Melamed, M. L.
    Langford, A. O.
    Daniel, J. S.
    Portmann, R. W.
    Miller, H. L.
    Eubank, C. S.
    Schofield, R.
    Holloway, J.
    Solomon, S.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2008, 113 (D2)
  • [2] Measurements of PANs during the New England air quality study 2002
    Roberts, J. M.
    Marchewka, M.
    Bertman, S. B.
    Sommariva, R.
    Warneke, C.
    de Gouw, J.
    Kuster, W.
    Goldan, P.
    Williams, E.
    Lerner, B. M.
    Murphy, P.
    Fehsenfeld, F. C.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2007, 112 (D20)
  • [3] A high precision pulsed quantum cascade laser spectrometer for measurements of stable isotopes of carbon dioxide
    McManus, JB
    Nelson, DD
    Shorter, JH
    Jimenez, R
    Herndon, S
    Saleska, S
    Zahniser, M
    JOURNAL OF MODERN OPTICS, 2005, 52 (16) : 2309 - 2321
  • [4] Quantum cascade laser-based spectrometer for high sensitive measurements of trace gases in air
    Tang, Yuanyuan
    Liu, Wenqing
    Kan, Ruifeng
    Zhang, Yujun
    Chen, Dong
    Zhang, Shuai
    Ruan, Jun
    CHINESE OPTICS LETTERS, 2012, 10 (04)
  • [5] Quantum cascade laser-based spectrometer for high sensitive measurements of trace gases in air
    汤媛媛
    刘文清
    阚瑞峰
    张玉钧
    陈东
    张帅
    阮俊
    Chinese Optics Letters, 2012, 10 (04) : 33 - 35
  • [6] Water-vapor isotope ratio measurements in air with a quantum-cascade laser spectrometer
    Joly, L
    Zéninari, V
    Parvitte, B
    Courtois, D
    Durry, G
    OPTICS LETTERS, 2006, 31 (02) : 143 - 145
  • [7] Nonmethane hydrocarbon and oxy hydrocarbon measurements during the 2002 New England Air Quality Study
    Goldan, PD
    Kuster, WC
    Williams, E
    Murphy, PC
    Fehsenfeld, FC
    Meagher, J
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2004, 109 (D21) : D213091 - 14
  • [8] New method for isotopic ratio measurements of atmospheric carbon dioxide using a 4.3 μm pulsed quantum cascade laser
    D.D. Nelson
    J.B. McManus
    S.C. Herndon
    M.S. Zahniser
    B. Tuzson
    L. Emmenegger
    Applied Physics B, 2008, 90 : 301 - 309
  • [9] New method for isotopic ratio measurements of atmospheric carbon dioxide using a 4.3 μm pulsed quantum cascade laser
    Nelson, D. D.
    Mcmanus, J. B.
    Herndon, S. C.
    Zahniser, M. S.
    Tuzson, B.
    Emmenegger, L.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (02): : 301 - 309
  • [10] Pulsed quantum cascade laser instrument with compact design for rapid, high sensitivity measurements of trace gases in air
    J.B. McManus
    J.H. Shorter
    D.D. Nelson
    M.S. Zahniser
    D.E. Glenn
    R.M. McGovern
    Applied Physics B, 2008, 92