共 50 条
Longitudinal study of multiple sclerosis lesions using ultra-high field (7T) multiparametric MR imaging
被引:33
|作者:
Chawla, Sanjeev
[1
,2
,3
]
Kister, Ilya
[4
]
Sinnecker, Tim
[5
]
Wuerfel, Jens
[5
]
Brisset, Jean-Christophe
[1
,2
]
Paul, Friedemann
[6
,7
,8
,9
,10
,11
]
Ge, Yulin
[1
,2
]
机构:
[1] Ctr Adv Imaging Innovat & Res, New York, NY USA
[2] Bernard & Irene Schwartz Ctr Biomed Imaging, Dept Radiol, New York, NY USA
[3] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
[4] NYU, Dept Neurol, Sch Med, New York, NY 10016 USA
[5] Med Image Anal Ctr AG, Basel, Switzerland
[6] Charite Univ Med Berlin, NeuroCure Clin Res Ctr, Berlin, Germany
[7] Free Univ Berlin, Berlin, Germany
[8] Humboldt Univ, Berlin, Germany
[9] Berlin Inst Hlth, Berlin, Germany
[10] Max Delbrueck Ctr Mol Med, Expt & Clin Res Ctr, Berlin, Germany
[11] Charite Univ Med Berlin, Berlin, Germany
来源:
基金:
美国国家卫生研究院;
关键词:
WHITE-MATTER;
IRON;
SUSCEPTIBILITY;
BRAIN;
PATHOLOGY;
CONTRAST;
D O I:
10.1371/journal.pone.0202918
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Pathophysiology of multiple sclerosis (MS) lesions is dynamic and changes over time. The purpose of this exploratory study was to determine the longitudinal changes in MS lesions over time on ultra-high field MR imaging. Nine patients with MS underwent high-resolution 3D-susceptibility weighted imaging (SWI) and 2D-gradient-echo-T2*-weighted imaging on 7T MRI at baseline and after similar to 2.4 years of follow-up. Morphologic imaging characteristics, signal intensity patterns and quantitative susceptibility mapping (QSM) values of lesions were recorded at both time points. Lesions were classified as "iron-laden" if they demonstrated hypointense signal on T2*-weighted images and/or SWI as well as hyperintense signal on QSM. Lesions were considered "non-iron-laden" if they were hyperintense on T2*/SWI and isointense or hyperintense on QSM. Total of 162 non-iron-laden and 29 iron-laden lesions were observed at baseline. No change in baseline lesion size during follow up was recorded in 92.7%; no change in lesion-vessel relationship in 86.5%; and no change in signal intensity pattern in 96.9% of lesions. Three lesions which were non-iron-laden at baseline, exhibited iron at follow-up. In two iron-laden lesions, redistribution of iron content was observed at follow-up. Two-thirds of these iron-laden lesions showed an increase in QSM at follow-up relative to baseline, and the remaining one-third exhibited decrease in QSM. Most of the newly formed lesions (11/13, 84.6%) at follow-up were iron-laden. 7T multiparametric MRI is a useful tool for tracking the evolution of MS lesions, especially with regard to changes in iron content.
引用
收藏
页数:16
相关论文