Anterior decompression and hybrid reconstruction with titanium mesh cage plus plate and self-locking stand-alone cage for the treatment of three-level cervical spondylotic myelopathy

被引:8
|
作者
Zhou, Jian [1 ]
Li, Xilei [1 ]
Zhou, Xiaogang [1 ]
Lin, Hong [1 ]
Dong, Jian [1 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Orthopaed Surg, 180 Fenglin Rd, Shanghai 200032, Peoples R China
关键词
Adjacent three-level cervical spondylotic myelopathy; Hybrid reconstruction; Titanium mesh cage; Self-locking stand-alone cage; FOLLOW-UP; CORPECTOMY; DISKECTOMY; FUSION; DYSPHAGIA; STRUT; METAANALYSIS; ARTHRODESIS; FIXATION; OUTCOMES;
D O I
10.1016/j.jocn.2017.04.022
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
It has been reported that anterior cervical decompression has good clinical outcomes for the treatment of adjacent three-level cervical spondylotic myelopathy (CSM). However, the application of a long plate in the anterior cervical spine poses substantial risks of soft tissue damage. In this retrospective study, we aimed to analyze the clinical and radiological results of the hybrid construction with titanium mesh cage (TMC) plus plate and self-locking stand-alone cage for treatment of adjacent three-level CSM. A total of 28 consecutive patients with adjacent three-level CSM were treated by anterior decompression and hybrid reconstruction with TMC plus plate and self-locking stand-alone cage. Clinical outcomes, complications, fusion rate and time, cage subsidence and spinal curvature were assessed. The mean follow-up period was 22.8 months. The average operative time was 103 +/- 18.5 min, and the average blood loss was 115 +/- 13.3 mL. The JOA score and degree of spinal curvature were significantly increased at the final follow-up compared with preoperatively (P < 0.05). Twenty-seven cases finally achieved a solid fusion, and the average time to achieve a solid fusion was 6.2 months. Postoperative complications included one case of cerebrospinal fluid leakage (3.57%), one case of temporary sore throat (3.57%) and two cases of TMC subsidence (7.1%). No dysphagia and hoarseness were observed. Anterior decompression and hybrid reconstruction with TMC plus plate and self-locking stand-alone cage could be used safely and effectively for the treatment of adjacent three-level CSM. It could effectively restore cervical lordosis, reduce the complications related to long plate fixation, and lead to satisfactory outcomes. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 41 条
  • [1] The application of a new type of titanium mesh cage in hybrid anterior decompression and fusion technique for the treatment of continuously three-level cervical spondylotic myelopathy
    Xiaowei Liu
    Yu Chen
    Haisong Yang
    Tiefeng Li
    Haidong Xu
    Bin Xu
    Deyu Chen
    European Spine Journal, 2017, 26 : 122 - 130
  • [2] The application of a new type of titanium mesh cage in hybrid anterior decompression and fusion technique for the treatment of continuously three-level cervical spondylotic myelopathy
    Liu, Xiaowei
    Chen, Yu
    Yang, Haisong
    Li, Tiefeng
    Xu, Haidong
    Xu, Bin
    Chen, Deyu
    EUROPEAN SPINE JOURNAL, 2017, 26 (01) : 122 - 130
  • [3] Clinical and imaging outcomes of self-locking stand-alone cages and anterior cage-with-plate in three-level anterior cervical discectomy and fusion: a retrospective comparative study
    Liang Tang
    Xiaoming Liu
    Yanghu Lu
    Yanbin Liu
    Jiangming Yu
    Jian Zhao
    Journal of Orthopaedic Surgery and Research, 18
  • [4] Clinical and imaging outcomes of self-locking stand-alone cages and anterior cage-with-plate in three-level anterior cervical discectomy and fusion: a retrospective comparative study
    Tang, Liang
    Liu, Xiaoming
    Lu, Yanghu
    Liu, Yanbin
    Yu, Jiangming
    Zhao, Jian
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [5] Three-level anterior cervical discectomy and fusion with self-locking stand-alone polyetheretherketone cages
    Zhou, Jian
    Li, Xilei
    Dong, Jian
    Zhou, Xiaogang
    Fang, Taolin
    Lin, Hong
    Ma, Yiqun
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (11) : 1505 - 1509
  • [6] Comparison of plate-cage construct and stand-alone anchored spacer in the surgical treatment of three-level cervical spondylotic myelopathy: a preliminary clinical study
    Shi, Sheng
    Liu, Zu-De
    Li, Xin-Feng
    Qian, Lie
    Zhong, Gui-Bin
    Chen, Fang-Jing
    SPINE JOURNAL, 2015, 15 (09): : 1973 - 1980
  • [7] Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patients
    Yan, Denglu
    Wang, Zhaojie
    Deng, Shaojie
    Li, Jian
    Soo, Chenglong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (10) : 1369 - 1374
  • [8] Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patients
    Denglu Yan
    Zhaojie Wang
    Shaojie Deng
    Jian Li
    Chenglong Soo
    Archives of Orthopaedic and Trauma Surgery, 2011, 131
  • [9] Comparison of Clinical and Radiologic Outcomes Between Self-Locking Stand-Alone Cage and Cage with Anterior Plate for Multilevel Anterior Cervical Discectomy and Fusion: A Meta-Analysis
    Zhang, Duo
    Liu, Baoge
    Zhu, Jichao
    Li, Chenxi
    Wei, Fengning
    Yuan, Yuan
    Zhu, Di
    WORLD NEUROSURGERY, 2019, 125 : E117 - E131
  • [10] Cervical spine fusion: Biomechanics of a three-level cadaver model comparing anterior plate versus stand-alone cage
    McGuire R.
    Al-Barghouthi A.
    Dale W.
    Travascio F.
    Latta L.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (02) : 135 - 140