Concentration independent calibration of β-γ coincidence detector using 131mXe and 133Xe

被引:8
|
作者
McIntyre, Justin I. [1 ]
Cooper, Mathew [1 ]
Carman, April J. [1 ]
Bowyer, Theodore W. [1 ]
Day, Anthony [1 ]
Haas, Derek [1 ]
Hayes, James C. [1 ]
Heimbigner, Tom R. [1 ]
Hubbard, Charlie [1 ]
Litke, Kevin [1 ]
Ripplinger, Michael [1 ]
Schrom, Brian [1 ]
Suarez, Reynold [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
Radioxenon; Coincidence counting; Nuclear detector calibration; Xe-133; Xe-131m; CTBTO; International monitoring system (IMS); Automated radioxenon sampler/analyzer (ARSA);
D O I
10.1007/s10967-009-0311-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the beta-gamma coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable (Reeder et al., J Radioanal Nucl Chem, 235, 1989). A superior technique has been developed that uses the conversion-electron (CE) and X-ray coincidence of Xe-131m to provide a more accurate absolute gamma efficiency of the detector. The Xe-131m is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, Xe-133 is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.
引用
收藏
页码:755 / 759
页数:5
相关论文
共 50 条
  • [1] Concentration independent calibration of β–γ coincidence detector using 131mXe and 133Xe
    Justin I. McIntyre
    Mathew Cooper
    April J. Carman
    Theodore W. Bowyer
    Anthony Day
    Derek Haas
    James C. Hayes
    Tom R. Heimbigner
    Charlie Hubbard
    Kevin Litke
    Michael Ripplinger
    Brian Schrom
    Reynold Suarez
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 755 - 759
  • [2] Modeling β-γ coincidence spectra of 131mXe, 133Xe, 133mXe, and 135Xe
    Haas, D. A.
    Biegalski, S. R.
    Biegalski, K. M. Foltz
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 277 (03) : 561 - 565
  • [3] Modeling β-γ coincidence spectra of 131mXe, 133Xe, 133mXe, and 135Xe
    D. A. Haas
    S. R. Biegalski
    K. M. Foltz Biegalski
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 277
  • [4] SDAT: analysis of 131mXe with 133Xe interference
    Biegalski, S. R. F.
    Biegalski, K. M. Foltz
    Haas, D. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (03) : 715 - 719
  • [5] SDAT: analysis of 131mXe with 133Xe interference
    S. R. F. Biegalski
    K. M. Foltz Biegalski
    D. A. Haas
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 715 - 719
  • [6] Global emission inventory of 131mXe, 133Xe, 133mXe, and 135Xe from all kinds of nuclear facilities for the reference year 2014
    Kalinowski, Martin B.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2023, 261
  • [7] DECAY OF 133XE AND 133MXE
    ALEXANDER, P
    LAU, JP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (04): : 625 - +
  • [8] 133Xe和131mXe混合气体刻度氙符合系统探测效率
    赵允刚
    贾怀茂
    王世联
    李奇
    张新军
    樊元庆
    陈占营
    常印忠
    刘蜀疆
    核技术, 2013, 36 (03) : 22 - 26
  • [9] Calculation of electron-photon coincidence decay of 131mXe and 133mXe including atomic relaxation
    Ringbom, A.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (08) : 1499 - 1508
  • [10] Determination of 131mXe and 133mXe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence
    P. L. Reeder
    T. W. Bowyer
    J. I. McIntyre
    W. K. Pitts
    Journal of Radioanalytical and Nuclear Chemistry, 2001, 248 : 617 - 622