Examination of poly-capillary lenses for their use in micro-XRF spectrometers

被引:28
|
作者
Haschke, M [1 ]
Haller, M
机构
[1] Rontgenanalyt Messtechn GmbH, Taunusstein, Germany
[2] Xray Opt Syst Inc, Albany, NY 12203 USA
关键词
D O I
10.1002/xrs.636
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The availability of poly-capillary lenses opens up a wide variety of possibilities for the analysis of small sample areas because a large part of the tube radiation can captured and focused on the sample. Propagation in the glass capillaries is achieved by external total reflection on their internal surface. At first the intensity gain of the lenses and their spot size were the most interesting parameters. However, by using these lenses in commercial instruments, other parameters became more important for characterizing their performance for spectroscopic use, e.g. the energy dependence of the spot size and of the transmission efficiency and their influence to the tube spectrum. In this paper, the examination of various lenses from different manufacturers is described. It is shown that for the main parameters spot size and intensity gain, the differences are negligible. However, other parameters can be influenced by the change in geometric parameters of the lens such as the diameter of the single capillaries and bending radius of the lenses. These changes need high perfection in lens manufacturing. It seems that at present only one of the manufacturers is able to control the process in this way. However, there is also another requirement for the implementation of lenses for commercial instruments, namely the uniformity of the outer dimensions. Only in this case can these components be used without special adaptation in a routine instrument. This also requires the complete Control of the manufacturing process. Because the use of poly-capillary lenses is in its early stages, it seems necessary to define more exactly the parameters that characterize the x-ray optical components. Only in this case will it be possible to define the performance of the optics with high precision and compare lenses from different manufacturers. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
下载
收藏
页码:239 / 247
页数:9
相关论文
共 12 条
  • [1] Comparison of two confocal micro-XRF spectrometers with different design aspects
    Smolek, S.
    Nakazawa, T.
    Tabe, A.
    Nakano, K.
    Tsuji, K.
    Streli, C.
    Wobrauschek, P.
    X-RAY SPECTROMETRY, 2014, 43 (02) : 93 - 101
  • [2] A micro-XRF spectrometer based on a rotating anode generator and capillary optics
    Janssens, K
    Vekemans, B
    Vincze, L
    Adams, F
    Rindby, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (13) : 1661 - 1678
  • [3] Micro-XRF spectrometer based on a rotating anode generator and capillary optics
    Univ of Antwerp , Antwerp, Belgium
    Spectrochim Acta Part B At Spectrosc, 1600, 13 (1661-1678):
  • [4] Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination
    Zeigler, R. A.
    Righter, K.
    Allen, C. C.
    METEORITICS & PLANETARY SCIENCE, 2013, 48 : A388 - A388
  • [5] Simulation of poly-capillary lenses for coherent and partially coherent x-rays
    Vincze, L
    Kukhlevsky, SV
    Janssens, K
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY AND NEUTRON OPTICS, 2004, 5536 : 81 - 85
  • [6] Synchrotron micro-XRF with Compound Refractive Lenses (CRLs) for tracing key elements on Portuguese glazed ceramics
    Guilherme, A.
    Buzanich, G.
    Radtke, M.
    Reinholz, U.
    Coroado, J.
    Dos Santos, J. M. F.
    Carvalho, M. L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (06) : 966 - 974
  • [7] A simple calibration procedure of polycapillary based portable micro-XRF spectrometers for reliable quantitative analysis of cultural heritage materials
    Kantarelou, V.
    Karydas, A. G.
    X-RAY SPECTROMETRY, 2016, 45 (02) : 85 - 91
  • [8] The use of synchrotron micro-XRF for characterization of the micro-heterogeneity of heavy metals in low-Z reference materials
    Kempenaers, L
    Vincze, L
    Janssens, K
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (06) : 651 - 669
  • [9] An X-ray focusing monochromator composed of poly-capillary X-ray lenses and highly oriented pyrolytic graphite
    Wang, Xingyi
    Zhou, Mo
    Duan, Jiayu
    Luo, Heng
    Liu, Xin
    Lin, Xiaoyan
    Li, Yude
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 461 : 256 - 259
  • [10] The Development and Its Applications of a Software Fitting Micro-X-Ray Fluorescence Spectrum Focused by Poly-Capillary Optics
    Shuai Qi-lin
    Liu Jun
    Shao Jin-fa
    Jiang Qi-li
    Li Rong-wu
    Pan Qui-li
    Cheng Lin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (03) : 714 - 719