Diagnostic Accuracy of Spectralis SD OCT Automated Macular Layers Segmentation to Discriminate Normal from Early Glaucomatous Eyes

被引:87
|
作者
Pazos, Marta [1 ,2 ,3 ]
Anna Dyrda, Agnieszka [1 ,4 ]
Biarnes, Marc [3 ]
Gomez, Alicia [5 ]
Martin, Carlos [4 ,5 ]
Mora, Clara [1 ]
Fatti, Gianluca [1 ]
Anton, Alfonso [1 ,2 ,5 ,6 ]
机构
[1] Univ Pompeu Fabra, Hosp Esperanca, Dept Ophthalmol, Parc Salut Mar,San Josep Muntanya 12, Barcelona 08024, Spain
[2] Inst Mar Invest Med, Barcelona, Spain
[3] Ctr Med Teknon, Inst Macula, Barcelona, Spain
[4] Inst Catala Retina, Dept Retina, Barcelona, Spain
[5] Inst Catala Retina, Dept Glaucoma, Barcelona, Spain
[6] Univ Int Catalunya, Dept Ophthalmol, Barcelona, Spain
关键词
NERVE-FIBER LAYER; OPTICAL COHERENCE TOMOGRAPHY; GANGLION-CELL COMPLEX; THICKNESS MEASUREMENT; ATROPHY; HEAD; ABILITY; DISC;
D O I
10.1016/j.ophtha.2017.03.044
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of the macular retinal layer segmentation software of the Spectralis spectral-domain (SD) optical coherence tomography (OCT) device (Heidelberg Engineering, Inc., Heidelberg, Germany) to discriminate between healthy and early glaucoma (EG) eyes. Design: Prospective, cross-sectional study. Participants: Forty EG eyes and 40 healthy controls were included. Methods: All participants were examined using the standard posterior pole and the peripapillary retinal nerve fiber layer (pRNFL) protocols of the Spectralis OCT device. Using an Early Treatment Diagnostic Retinopathy Study circle at the macular level, the automated retinal segmentation software was applied to determine thicknesses of the following parameters: total retinal thickness, inner retinal layer (IRL), macular retinal nerve fiber layer (mRNFL), macular ganglion cell layer (mGCL), macular inner plexiform layer (mIPL), macular inner nuclear layer (mINL), macular outer plexiform layer (mOPL), macular outer nuclear layer (mONL), photoreceptors (PR), and retinal pigmentary epithelium (RPE). The ganglion cell complex (GCC) was determined by adding the mRNFL, mGCL, and mIPL parameters and the ganglion cell layereinner plexiform layer (mGCLIPL) was determined by combining the mGCL and mIPL parameters. Thickness of each layer was compared between the groups, and the layer and sector with the best area under the receiver operating characteristic curve (AUC) were identified. Main Outcome Measures: Comparison of pRNFL, IRL, mRNFL, mGCL, mIPL, mGCC, mGCL-IPL, mINL, mOPL, mONL, PR, and RPE parameters and total retinal thicknesses between groups for the different areas and their corresponding AUCs. Results: Peripapillary RNFL was significantly thinner in the EG group globally and in all 6 sectors assessed (P < 0.0005). For the macular variables, retinal thickness was significantly reduced in the EG group for total retinal thickness, mIRL, mRNFL, mGCL, and mIPL. The 2 best isolated parameters to discriminate between the 2 groups were pRNFL (AUC, 0.956) and mRNFL (AUC, 0.906). When mRNFL, mGCL, and mIPL measurements were combined (mGCC and mGCL plus mIPL), then its diagnostic performance improved (AUC, 0.940 and 0.952, respectively). Conclusions: Macular RNFL, mGCL-IPL, and mGCC measurements showed a high diagnostic capability to discriminate between healthy and EG participants. However, macular intraretinal measurements still have not overcome standard pRNFL parameters.
引用
收藏
页码:1218 / 1228
页数:11
相关论文
共 19 条
  • [1] Re: Pazos et al.: Diagnostic accuracy of Spectralis SDOCT automated macular layers segmentation to discriminate normal from early glaucomatous eyes (Ophthalmology. 2017; 124: 1218-1228)
    Qiu, Kunliang
    Zhang, Mingzhi
    OPHTHALMOLOGY, 2018, 125 (03) : E20 - E21
  • [2] Re: Pazos et al.: Diagnostic accuracy of Spectralis SDOCT automated macular layers segmentation to discriminate normal from early glaucomatous eyes (Ophthalmology. 2017;124:1218-1228) REPLY
    Pazos, Marta
    Dyrda, Agnieszka
    Biarnes, Marc
    Anton, Alfonso
    OPHTHALMOLOGY, 2018, 125 (03) : E21 - E22
  • [3] Diagnostic Accuracy of Macular Ganglion Cell Layer Thickness Measured by Spectralis SD OCT versus Retinal Nerve Fibre Layer thickness in Discriminating Normal from Glaucomatous eyes
    Elias, Anna
    Anantharaman, Giridhar
    Janardhanan, Saikumar Seshadri
    Nair, Abhilash
    Anup, Manju
    Jacob, Sara
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [4] Automated intraretinal segmentation of SD-OCT images in normal and age-related macular degeneration eyes
    de Sisternes, Luis
    Jonna, Gowtham
    Moss, Jason
    Marmor, Michael F.
    Leng, Theodore
    Rubin, Daniel L.
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03): : 1926 - 1949
  • [5] Assessing reproducibility and the effects of demographic variables on the normal macular layers using the Spectralis SD-OCT
    Hashmani, Nauman
    Hashmani, Sharif
    Murad, Asif
    Mahmood, Sayed Mustafa
    Hashmani, Shah Maria
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1433 - 1440
  • [6] Layer by Layer Automated Retinal Segmentationwith SD-OCT in the Macula of Normal and Glaucomatous Eyes
    Pazos, Marta
    Anna Dyrda, Agnieszka
    Gomez, Alicia
    Martin, Carlos
    Anton-Lopez, Alfonso
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [7] Diagnostic ability of inner macular layers to discriminate early glaucomatous eyes using vertical and horizontal B-scan posterior pole protocols
    Bambo, Maria P.
    Cameo, Beatriz
    Hernandez, Ruben
    Fuentemilla, Enrique
    Guerri, Noemi
    Ferrandez, Blanca
    Polo, Vicente
    Larrosa, Jose M.
    Pablo, Luis E.
    Garcia-Martin, Elena
    PLOS ONE, 2018, 13 (06):
  • [8] Ability of Cirrus HD-OCT Optic Nerve Head Parameters to Discriminate Normal from Glaucomatous Eyes
    Mwanza, Jean-Claude
    Oakley, Jonathan D.
    Budenz, Donald L.
    Anderson, Douglas R.
    OPHTHALMOLOGY, 2011, 118 (02) : 241 - U34
  • [9] Validation of Macular Choroidal Thickness Measurements from Automated SD-OCT Image Segmentation
    Twa, Michael D.
    Schulle, Krystal L.
    Chiu, Stephanie J.
    Farsiu, Sina
    Berntsen, David A.
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (11) : 1387 - 1398
  • [10] RNFL attenuation coefficients for normal and glaucomatous eyes from standard peripapillary SD-OCT circle scans
    Thepass, Gijs
    de Boer, Johannes F.
    Lemij, Hans G.
    Vermeer, Koenraad Arndt
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)