Single-incision transaxillary robotic total thyroidectomy for Graves' disease: improved feasibility and safety with novel robotic instrumentation

被引:4
|
作者
Loerincz, Balazs B. [1 ,2 ]
Moeckelmann, Nikolaus [1 ,2 ]
Knecht, Rainald [1 ,2 ]
机构
[1] Hubertus Wald Univ Canc Ctr Hamburg, Head & Neck Canc Ctr, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Otorhinolaryngol Head & Neck Surg & Oncol, D-20246 Hamburg, Germany
关键词
Transaxillary robotic surgery (TARS); Graves' disease; Total thyroidectomy; Vascularity; Bleeding risk; 8 mm Fenestrated bipolar forceps; INITIAL-EXPERIENCE; SUBTOTAL THYROIDECTOMY; AXILLO-BREAST; GASLESS; MANAGEMENT;
D O I
10.1007/s00405-014-3250-9
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Graves' disease represents a relative contraindication for robotic thyroidectomy due to increased vascularity with a higher risk of intraoperative bleeding. With a novel robotic instrumentation, however, it is possible to reduce this risk considerably. A 30-year-old female patient with Graves' disease and keloid-prone olive skin underwent a single-incision transaxillary robotic total thyroidectomy through the left axilla using an 8-mm Fenestrated bipolar forceps instead of the standard 8-mm ProGrasp forceps. Total blood loss was 25 ml, and robotic console time was 132 min. There was no postoperative recurrent palsy. Postoperative parathormone level was 47 ng/l (preop.: 56 ng/l), and serum calcium level was normal at 2,17 mmol/l (preop.: 2,23 mmol/l). Transaxillary robotic surgery (TARS) with unilateral single-incision access is feasible and safe for Graves' disease with minimal blood loss and reduced risk of conversion thanks to the bipolar capability of the 8-mm Fenestrated bipolar forceps.
引用
收藏
页码:3349 / 3353
页数:5
相关论文
共 49 条
  • [1] Single-incision transaxillary robotic total thyroidectomy for Graves’ disease: improved feasibility and safety with novel robotic instrumentation
    Balazs B. Lörincz
    Nikolaus Möckelmann
    Rainald Knecht
    European Archives of Oto-Rhino-Laryngology, 2014, 271 : 3349 - 3353
  • [2] Feasibility and Safety of a New Robotic Thyroidectomy Through a Gasless, Transaxillary Single-Incision Approach Reply
    Ryu, Haeng Rang
    Kang, Sang-Wook
    Chung, Woong Youn
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2011, 212 (06) : 1097 - 1098
  • [3] Prevention of Complications in Transaxillary Single-Incision Robotic Thyroidectomy
    Nam, Kee-Hyun
    Owen, Randall
    Inabnet, William B., III
    THYROID, 2012, 22 (12) : 1266 - 1274
  • [4] Safety and Feasibility of Robotic Transaxillary Thyroidectomy for Graves' Disease: A Retrospective Cohort Study
    Bshait, Mohammed Saad Bu
    Kim, Jin Kyong
    Lee, Cho Rok
    Kang, Sang-Wook
    Jeong, Jong Ju
    Nam, Kee-Hyun
    Chung, Woong Youn
    WORLD JOURNAL OF SURGERY, 2022, 46 (05) : 1107 - 1113
  • [5] Safety and Feasibility of Robotic Transaxillary Thyroidectomy for Graves’ Disease: A Retrospective Cohort Study
    Mohammed Saad Bu Bshait
    Jin Kyong Kim
    Cho Rok Lee
    Sang-Wook Kang
    Jong Ju Jeong
    Kee-Hyun Nam
    Woong Youn Chung
    World Journal of Surgery, 2022, 46 : 1107 - 1113
  • [6] Bilateral vagal automatic periodic stimulation in single-incision transaxillary robotic total thyroidectomy
    Aidan, P.
    Chung, W. Y.
    Loerincz, B. B.
    CLINICAL OTOLARYNGOLOGY, 2018, 43 (01) : 401 - 403
  • [7] Thyroidectomy for Graves' Disease: A Feasibility Study of the Robotic Transaxillary Approach
    Noureldine, Salem I.
    Yao, Lu
    Wavekar, Rohan R.
    Mohamed, Salah
    Kandil, Emad
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, 2013, 75 (06): : 350 - 356
  • [8] Robotic transaxillary total thyroidectomy through a single axillary incision
    Aliyev, Shamil
    Taskin, Halit Eren
    Agcaoglu, Orhan
    Aksoy, Erol
    Milas, Mira
    Siperstein, Allan
    Berber, Eren
    SURGERY, 2013, 153 (05) : 705 - 710
  • [9] Correction to: Safety and Feasibility of Robotic Transaxillary Thyroidectomy for Graves’ Disease: A Retrospective Cohort Study
    Mohammed Saad Bu Bshait
    Jin Kyong Kim
    Cho Rok Lee
    Sang-Wook Kang
    Jong Ju Jeong
    Kee-Hyun Nam
    Woong Youn Chung
    World Journal of Surgery, 2022, 46 : 1508 - 1508
  • [10] Automatic periodic stimulation of the vagus nerve during single-incision transaxillary robotic thyroidectomy: Feasibility, safety, and first cases
    Loerincz, Balazs B.
    Moeckelmann, Nikolaus
    Busch, Chia-Jung
    Hezel, Markus
    Knecht, Rainald
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2016, 38 (03): : 482 - 485