Effect of tumescent anesthesia and patient positioning on laser tip junctional distance during endovenous laser ablation

被引:4
|
作者
Al Shakarchi, Julien [1 ]
Kay, Mark [1 ]
Kuyumdzhiev, Smilen [1 ]
Psarros, Vasileios [1 ]
Rogoveanu, Radu [1 ]
Vohra, Rajiv [1 ]
机构
[1] Univ Hosp Birmingham, Dept Vasc Surg, Birmingham B15 2TH, W Midlands, England
关键词
RANDOMIZED CLINICAL-TRIAL; SAPHENOUS VARICOSE-VEINS; CONVENTIONAL SURGERY; GUIDELINES; SOCIETY;
D O I
10.1016/j.jvsv.2017.08.013
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The correct positioning of the laser tip at the saphenofemoral or saphenopopliteal junction during endovenous laser therapy is paramount to ensure a safe and effective procedure. The aim of this study was to demonstrate how patient positioning and tumescence infiltration can affect this safe junctional distance. Methods: A retrospective review of a prospectively maintained database was carried out for all patients who received endovenous laser treatment for symptomatic varicose veins between February 2008 and February 2014 in one surgeon's practice in a teaching hospital vascular unit. The junctional distance of the laser tip from the saphenofemoral or saphenopopliteal junction was measured two times during the procedure: before tumescence and before laser deployment with the patient in a Trendelenburg position. Results: Junctional distance was found to have increased in 62% cases (490 patients; great saphenous vein [GSV]. 348; small saphenous vein [SSV],142). Of these, 17% (84) required the laser tip to be advanced (GSV. 56: SSV. 28) to maintain a desired junctional distance of 0.75 to 2 cm. In 185 patients (23%), the junctional distance was noted to have been reduced (GSV,155; SSV, 30), with 58% (GSV, 79; SSV, 28) requiring the laser tip to be withdrawn to the desired junctional distance; 23% of patients (185) had no change in the junctional distance. Conclusions: This study has demonstrated the effect of tumescence infiltration and Trendelenburg positioning on laser tip placement, and thus a final junctional measurement before activation of the laser is recommended to maintain a safe and optimal junctional distance.
引用
收藏
页码:220 / 223
页数:4
相关论文
共 50 条
  • [1] IS TUMESCENT ANESTHESIA NECESSARY FOR ENDOVENOUS LASER ABLATION?
    Wright, Thomas
    Bowman, Nicole
    Atnip, Elizabeth
    LASERS IN SURGERY AND MEDICINE, 2009, : 72 - 72
  • [2] Is the temperature of tumescent anesthesia applied in the endovenous laser ablation important? Comparison of different temperatures for tumescent anesthesia applied during endovenous ablation of incompetent great saphenous vein with a 1470 nm diode laser
    Abud, Burcin
    Karaarslan, Kemal
    Turhan, Soysal
    Karaman, Yucel
    VASCULAR, 2014, 22 (06) : 421 - 426
  • [3] Comparing cold and warm tumescent anesthesia for pain perception during and after the endovenous laser ablation procedure with 1470 nm diode laser
    Dumantepe, Mert
    Uyar, Ibrahim
    PHLEBOLOGY, 2015, 30 (01) : 45 - 51
  • [4] It is Possible to Cause Damage to a Laser Fibre during Delivery of Tumescent Anaesthesia for Endovenous Laser Ablation (EVLA)
    Holdstock, J. M.
    Marsh, P.
    Whiteley, M. S.
    Price, B. A.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 36 (04) : 473 - 476
  • [5] Defining the optimum tumescent anaesthesia solution in endovenous laser ablation
    Wallace, Tom
    Leung, Clement
    Nandhra, Sandip
    Samuel, Nehemiah
    Carradice, Daniel
    Chetter, Ian
    PHLEBOLOGY, 2017, 32 (05) : 322 - 333
  • [6] Simple system for perivenous tumescent infusion for endovenous laser ablation
    Alomari, A. I.
    PHLEBOLOGY, 2012, 27 (05) : 242 - 244
  • [7] Combination technique of tumescent anesthesia during endovenous laser therapy of saphenous vein insufficiency
    Memetoglu, Mehmet Erdem
    Kurtcan, Serpil
    Kalkan, Asim
    Ozel, Deniz
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 11 (06) : 774 - 777
  • [8] Effect of infiltration of tumescent anaesthesia (TA) and patient positioning on distance between sapheno-femoral junction (SFJ) and laser fibre-tip during endo-venous laser ablation (EVLA) of Great Saphenous Vein (GSV)
    Rai, S.
    Abdel-Hamid, M.
    Chan, R.
    Vohra, R.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 43 - 43
  • [9] Endovenous Laser Ablation of Great Saphenous Veins Performed Using Tumescent Cold Saline Solution without Local Anesthesia
    Cavallini, Alvise
    Marcer, Daniela
    Bernardini, Giovanni
    Ruffino, Salvatore Ferrari
    ANNALS OF VASCULAR SURGERY, 2014, 28 (04) : 951 - 956
  • [10] Comparison of laser power output from the fiber tip during endovenous laser ablation against displayed power and the "first treatment" effect
    Davies, Charlotte E.
    Riley, Max, I
    Dabbs, Emma B.
    Whiteley, Mark S.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2021, 9 (04) : 1051 - 1056