Fabrication of Cu-hemin metal-organic-frameworks nanoflower supported on three-dimensional reduced graphene oxide for the amperometric detection of H2O2

被引:19
|
作者
Zhou, Shiying [1 ]
Jiang, Liuyi [1 ]
Zhang, Jiajin [2 ]
Zhao, Peng [1 ]
Yang, Mei [1 ]
Huo, Danqun [1 ]
Luo, Xiaogang [1 ]
Shen, Caihong [1 ,3 ]
Hou, Changjun [1 ,4 ]
机构
[1] Chongqing Univ, Key Lab Biorheol Sci & Technol, State & Local Joint Engn Lab Vasc Implants, Minist Educ,Bioengn Coll, Chongqing 400044, Peoples R China
[2] Emory Univ, Emory Coll Art & Sci, 201 Dowman Dr, Atlanta, GA 30322 USA
[3] Luzhou Laojiao Grp Co Ltd, Natl Engn Res Ctr Solid State Brewing, Luzhou 646000, Peoples R China
[4] Chongqing Univ, Sch Microelect & Commun Engn, Chongqing Key Lab Biopercept & Intelligent Inform, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Hydrogen peroxide; Cu-hemin MOFs; 3D-RGO; Reduced graphene oxide; Electrochemical sensor; NONENZYMATIC ELECTROCHEMICAL DETECTION; PEROXIDASE; PLATFORMS; ENZYME;
D O I
10.1007/s00604-021-04795-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical sensor based on Cu-hemin metal-organic-frameworks nanoflower/three-dimensional reduced graphene oxide (Cu-hemin MOFs/3D-RGO) was constructed to detect H2O2 released from living cells. The nanocomposite was synthesized via a facile co-precipitation method using hemin as the ligand, then decorated with 3D-RGO. The prepared Cu-hemin MOFs showed a 3D hollow spherical flower-like structure with a large specific surface area and mesoporous properties, which could load more biomolecules and greatly enhance the stability by protecting the activity of hemin. In addition, the introduction of 3D-RGO effectively enhanced the conductivity of Cu-hemin MOFs. Thus, the proposed sensor (Cu-hemin MOFs/3D-RGO/GCE) showed excellent electrochemical performances towards H2O2 with a wide linear range (10-24,400 mu M), high sensitivity (207.34 mu A mM(-1) cm(-2)), low LOD (0.14 mu M), and rapid response time (less than 3 s). Most importantly, we prepared a Cu-hemin MOFs/3D-RGO/ITO electrode with cells growing on it. Compared with detecting H2O2 in cell suspension by GCE-based electrode, adhesion of cells on ITO could shorten the diffusion distance of H2O2 from solution to the surface of the electrode and achieve in situ and a real-time monitor of H2O2 released by living cells. This self-supported sensing electrode showed great potential applications in monitoring the pathological and physiological dynamics of cancer cells.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Fabrication of Cu-hemin metal-organic-frameworks nanoflower supported on three-dimensional reduced graphene oxide for the amperometric detection of H2O2
    Shiying Zhou
    Liuyi Jiang
    Jiajin Zhang
    Peng Zhao
    Mei Yang
    Danqun Huo
    Xiaogang Luo
    Caihong Shen
    Changjun Hou
    Microchimica Acta, 2021, 188
  • [2] Cu-Hemin Metal-Organic-Frameworks/Chitosan-Reduced Graphene Oxide Nanocomposites with Peroxidase-Like Bioactivity for Electrochemical Sensing
    Wang, Li
    Yang, Han
    He, Juan
    Zhang, Yayun
    Yu, Jie
    Song, Yonghai
    ELECTROCHIMICA ACTA, 2016, 213 : 691 - 697
  • [3] A novel Fe-hemin-metal organic frameworks supported on chitosan-reduced graphene oxide for real-time monitoring of H2O2 released from living cells
    Zhao, Peng
    Chen, Sha
    Zhou, Jun
    Zhang, Suyi
    Huo, Danqun
    Hou, Changjun
    ANALYTICA CHIMICA ACTA, 2020, 1128 : 90 - 98
  • [4] Non-Enzymatic Amperometric Detection of H2O2 on One-Step Electrochemical Fabricated Cu2O/Electrochemically Reduced Graphene Oxide Nanocomposite
    Dogan, Hulya O.
    Cepni, Emir
    Urhan, Bingul K.
    Eryigit, Mesut
    CHEMISTRYSELECT, 2019, 4 (28): : 8317 - 8321
  • [5] Amperometric Sensing of H2O2 using Pt-TiO2/Reduced Graphene Oxide Nanocomposites
    Leonardi, Salvatore Gianluca
    Aloisio, Davide
    Donato, Nicola
    Russo, Patricia A.
    Ferro, Marta C.
    Pinna, Nicola
    Neri, Giovanni
    CHEMELECTROCHEM, 2014, 1 (03): : 617 - 624
  • [6] Facile Preparation of Hemin-functionalized Electrochemically Reduced Graphene Oxide Nanocomposite for H2O2 Biosensing
    Chen, Zhi
    Liu, Dong
    Zhu, Chengxi
    Li, Libo
    You, Tianyan
    SENSORS AND MATERIALS, 2019, 31 (04) : 1167 - 1179
  • [7] Environmentally Friendly Reduction of Graphene Oxide Using Tyrosine for Nonenzymatic Amperometric H2O2 Detection
    Wang, Qi
    Li, Musen
    Szunerits, Sabine
    Boukherroub, Rabah
    ELECTROANALYSIS, 2014, 26 (01) : 156 - 163
  • [8] Colorimetric Detection Method for H2O2 Based on Two-dimensional Metal-organic Frameworks of Metalloporphyrin
    Xik, Xingyu
    Zhao, Yaxiang
    Zhao, Lizhi
    Li, Rishun
    Wu, Dihao
    Ye, Hui
    Xin, Qingping
    Li, Hong
    Zhang, Yuzhong
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2020, 41 (08): : 1776 - 1784
  • [9] Electrochemical Detection of H2O2 Using Copper Oxide-Reduced Graphene Oxide Heterostructure
    Kumar, J. Sharath
    Ghosh, Souvik
    Murmu, Naresh Chandra
    Mandal, Nilrudra
    Kuila, Tapas
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2019, 19 (08) : 5295 - 5302
  • [10] Enzyme-free Amperometric H2O2 Biosensor Based on Cu-Ag Bimetallic Nanoparticles with Reduced Graphene Oxide Nanocomposites
    Wu, Kong-Lin
    Li, Xiang-Zi
    Dong, Chao
    Liu, Li
    Liu, Pin-De
    Ding, Ting-Hui
    Lu, Jing
    Wei, Xian-Wen
    CHEMISTRY LETTERS, 2013, 42 (12) : 1466 - 1468