A SiGe Front-End Prototype for the Upgraded ATLAS Liquid Argon Calorimeter

被引:0
|
作者
Rescia, Sergio [1 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
关键词
D O I
10.1109/NSSMIC.2009.5402408
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have designed and fabricated a very low noise preamplifier and shaper to replace the existing ATLAS Liquid Argon readout for use at the Large Hadron Collider upgrade (SLHC). IBM's 8WL 130nm SiGe process was chosen for its radiation tolerance, low noise bipolar NPN devices, wide voltage range and potential use in other SLHC detector subsystems. Although the requirements for the final design have not been yet finalized, the prototype was designed to accommodate a 16 hit dynamic range. This was accomplished by using a single stage, low noise, wide dynamic range preamplifier followed by a dual range shaper. The low noise of the preamp is made possible by the low base spreading resistance of the silicon germanium NPN bipolar transistors. The relatively high voltage rating of the NPN transistors is exploited to allow a gain of 650V/A in the preamplifier which eases the input voltage noise requirement on the shaper. Each shaper stage is designed as a cascaded differential operational amplifier pair with a common mode operating point regulated by an internal feedback loop. Measurement of the fabricated circuits indicates their performance is consistent with the design specifications including the radiation tolerance targets.
引用
收藏
页码:1134 / 1137
页数:4
相关论文
共 50 条
  • [1] Optical links for ATLAS liquid argon calorimeter front-end electronics readout
    Liu, T.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [2] ATLAS liquid argon calorimeter front end electronics
    Buchanan, N. J.
    Chen, L.
    Gingrich, D. M.
    Liu, S.
    Chen, H.
    Damazio, D.
    Densing, F.
    Duffin, S.
    Farrell, J.
    Kandasamy, S.
    Kierstead, J.
    Lanni, F.
    Lissauer, D.
    Ma, H.
    Makowiecki, D.
    Muller, T.
    Radeka, V.
    Rescia, S.
    Ruggiero, R.
    Takai, H.
    Wolniewicz, K.
    Ghazlane, H.
    Hoummada, A.
    Hervas, L.
    Hott, T.
    Wilkens, H. G.
    Ban, J.
    Boettcher, S.
    Brooijmans, G.
    Chi, C. -Y.
    Caughron, S.
    Cooke, M.
    Copic, K.
    Dannheim, D.
    Gara, A.
    Haas, A.
    Katsanos, I.
    Parsons, J. A.
    Simion, S.
    Sippach, W.
    Zhang, L.
    Zhou, N.
    Eckstein, P.
    Kobel, M.
    Ladygin, E.
    Auge, E.
    Bernier, R.
    Bouchel, M.
    Bozzone, A.
    Breton, D.
    JOURNAL OF INSTRUMENTATION, 2008, 3
  • [3] Production, testing and commissioning of the front-end readout electronics for the ATLAS liquid argon calorimeter
    Dannheim, Dominik
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 589 - 593
  • [4] Development of ATLAS Liquid Argon Calorimeter front-end electronics for the HL-LHC
    Liu, T.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [5] Are switching power supplies acceptable for the Liquid Argon calorimeter front-end electronics?
    Citterio, M
    Kierstead, J
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 402 - 406
  • [6] Cryogenic GaAs front-end system for the liquid argon hadronic endcap calorimeter of atlas digital readout for module 0
    Fent, J
    Ban, J
    Brettel, H
    Dulny, B
    Haberer, W
    Oberlack, H
    Schacht, P
    Cheplakov, A
    Kyriunin, A
    Kurchaninov, L
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 400 - 405
  • [7] Radiation qualification of the front-end electronics for the readout of the ATLAS liquid argon calorimeters
    Buchanan, N. J.
    Chen, L.
    Gingrich, D. M.
    Liu, S.
    Chen, H.
    Damazio, D.
    Densing, F.
    Kierstead, J.
    Lanni, F.
    Lissauer, D.
    Ma, H.
    Makowiecki, D.
    Radeka, V.
    Rescia, S.
    Takai, H.
    Ban, J.
    Boettcher, S.
    Dannheim, D.
    Parsons, J. A.
    Simon, S.
    Sippach, W.
    Cheplakov, A.
    Golikov, V.
    Golubyh, S.
    Kukhtin, V.
    Kulagin, E.
    Ladygin, E.
    Luschikov, V.
    Obudovsky, V.
    Shalyugin, A.
    Puzo, P.
    Richer, J. P.
    Seguin-Moreau, N.
    de la Taille, C.
    Dumont-Dayot, N.
    Massol, N.
    Le Dortz, O.
    Hubaut, F.
    Laforge, B.
    Martin, D.
    Schwemling, Ph.
    Andrieux, M-L.
    Collot, J.
    Dzahini, D.
    Hostachy, J. Y.
    Martin, P.
    Brettel, H.
    Cwienk, W.
    Fent, J.
    Jakobs, K.
    JOURNAL OF INSTRUMENTATION, 2008, 3
  • [8] Design of a new front-end electronics test-bench for the upgraded ATLAS detector's Tile Calorimeter
    Kureba, C. O.
    Govender, M.
    Hofsajer, I.
    Ruan, X.
    Sandrock, C.
    Spoor, M.
    HIGH ENERGY PARTICLE PHYSICS WORKSHOP (HEPPW2015), 2015, 645
  • [9] Irradiation studies of Gb/s optical links developed for the front-end read-out of the ATLAS liquid argon calorimeter
    Andrieux, ML
    Dinkespiler, B
    Evans, G
    Gallin-Martel, L
    Lundquist, J
    Martin, O
    Pearce, M
    Stroynowski, R
    Ye, J
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 719 - 724
  • [10] Quality control tests of the front-end optical link components for the ATLAS Liquid Argon Calorimeter Phase-1 upgrade
    Deng, B.
    Thomas, J.
    Zhang, L.
    Baker, E.
    Barsallo, A.
    Bleile, M. L.
    Chen, C.
    Cohen, I
    Cruda, E.
    Fang, J.
    Feng, N.
    Gong, D.
    Hou, S.
    Huang, X.
    Lozano-Brown, T.
    Liu, C.
    Liu, T.
    Muhammad, A.
    Murphy, L. A.
    Price, P. M.
    Ray, J. H.
    Rhoades, C.
    Santhi, A. H.
    Sela, D.
    Sun, H.
    Wang, J.
    Wang, Z.
    Wang, Z.
    Xiao, L.
    Zhang, W.
    Zhao, X.
    Ye, J.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (08)