摘要
A new solid-phase extraction (SPE) method for the extraction, enrichment, and analysis of eight polybrominated diphenyl ethers (PBDEs) in water was developed. The current approach involves using a cross-linked starch-based polymer as an extraction adsorbent and determining the PBDE analytes of interest using gas chromatography-mass spectrometry in negative chemical ionization mode (GC-NCI-MS). The starch-based polymer was synthesized by the reaction of soluble starch with 4,4 '-methylene-bis-phenyldiisocyanate as a cross-linking agent in dry dimethylformamide. Various parameters impacting extraction efficiencies, such as adsorbent quantity, sample volumes, elution solvents and volumes, and methanol content, were carefully optimized. The 500 mg of starch-based polymer as an adsorbent used to extract 1000 mL of spiked water, presented high extraction recoveries of eight PBDEs. The linearity of the extraction process was investigated in the range of 1-200 ng L-1 for BDE-28, 47, 99, 100, and 5-200 ng L-1 for BDE-153, 154, 183, and 209, with coefficients of determination (r2) exceeding 0.990 for all PBDEs. The limits of detection (LODs) ranged from 0.06 to 1.42 ng L-1 (S/N = 3) and the relative standard deviation values (RSD) were between 3.6 and 9.5 percent (n = 5) under optimum conditions. The method was successfully used to analyze river and lake water samples, where it exhibited acceptable recovery values of 71.3 to 104.2%. Considering the excellent analytical performance and comparative cost advantage, we recommend the developed starch-based SPE method for routine extraction and analysis of PBDEs in water media.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Analysis of polybrominated diphenyl ethers in sewage sludge by matrix solid-phase dispersion and isotope dilution GC-MS
    Sanchez-Brunete, Consuelo
    Miguel, Ester
    Tadeo, Jose L.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (01) : 109 - 117
  • [2] Quadrupole GC-MS analysis of polybrominated diphenyl ethers (PBDE) in environmental samples
    Cole, J
    Phillips, E
    Conoley, M
    [J]. LC GC NORTH AMERICA, 2005, : 45 - 45
  • [3] SIMULTANEOUS ANALYSIS OF 50 PESTICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND GC-MS
    BENFENATI, E
    TREMOLADA, P
    CHIAPPETTA, L
    FRASSANITO, R
    BASSI, G
    DITORO, N
    FANELLI, R
    STELLA, G
    [J]. CHEMOSPHERE, 1990, 21 (12) : 1411 - 1421
  • [4] Analysis of polybrominated diphenyl ethers in atmospheric deposition and snow samples by solid-phase disk extraction
    Quiroz, Roberto
    Arellano, Lourdes
    Grimalt, Joan O.
    Fernandez, Pilar
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1192 (01) : 147 - 151
  • [5] Development of a solid-phase microextraction gas chromatography/tandem mass spectrometry method for polybrominated diphenyl ethers and polybrominated biphenyls in water samples
    Polo, M
    Gómez-Noya, G
    Quintana, JB
    Llompart, M
    García-Jares, C
    Cela, R
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1054 - 1062
  • [6] Dispersive solid-phase extraction combined with dispersive liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in plastic bottled beverage by GC-MS
    Han, Yi
    Jia, Xiaoyu
    Liu, Xinli
    Duan, Taicheng
    Chen, Hangting
    [J]. JOURNAL OF SEPARATION SCIENCE, 2011, 34 (09) : 1047 - 1054
  • [7] Development of an interface for directly coupled solid-phase extraction and GC-MS analysis
    Ollers, S
    vanLieshout, M
    Janssen, HG
    Cramers, CA
    [J]. LC GC-MAGAZINE OF SEPARATION SCIENCE, 1997, 15 (09): : 846 - &
  • [8] Solid-Phase Extraction of Polybrominated Diphenyl Ethers in Human Plasma – Comparison with an Open Column Extraction Method
    M. Karlsson
    A. Julander
    B. van Bavel
    G. Lindström
    [J]. Chromatographia, 2005, 61 : 67 - 73
  • [9] Solid-phase extraction of polybrominated diphenyl ethers in human plasma comparison with an open column extraction method
    Karlsson, M
    Julander, A
    van Bavel, B
    Lindström, G
    [J]. CHROMATOGRAPHIA, 2005, 61 (1-2) : 67 - 73
  • [10] Analysis of chlorophenols in water by solid-phase microextraction and GC-MS
    Jursíková, K
    Janda, V
    [J]. CHEMICKE LISTY, 1999, 93 (12): : 803 - 805