Experimental Validation of a Pin less Femoral Reference Array for Computer-Assisted Hip Arthroplasty

被引:9
|
作者
Renkawitz, Tobias [1 ]
Wegner, Melanie [2 ]
Gneiting, Sabine [2 ]
Haimerl, Martin [2 ]
Sendtner, Ernst [1 ]
Kalteis, Thomas [3 ]
Grifka, Joachim [1 ]
机构
[1] Univ Regensburg, Med Ctr, Dept Orthopaed Surg, Asklepios Klinikum Bad Abbach, D-93077 Bad Abbach, Germany
[2] BrainLAB AG, Feldkirchen, Germany
[3] Orthopaed Joint Practice, Munich, Germany
关键词
leg situation algorithm; hip arthroplasty; total joint replacement; computer-assisted surgery; total hip replacement; REGISTRATION; FRACTURE; HEAD;
D O I
10.1002/jor.21039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of computer navigation systems during total hip arthroplasty requires the femoral fixation of a reflective dynamic reference base (DRB), which theoretically involves the risk of bony fracture, infection, and pin loosening. The first objective of this study was to evaluate the relative movements between a novel, noninvasive external femoral DRB system and the femur. Secondly, the maximum effects of these 3D movements on intraoperative, computer-assisted leg length and offset measures were evaluated. An imageless navigation system was used to track the positions of the soft tissue attached, pinless DRB relative to an invasive reference marker on the femur during a less-invasive, anterior surgical hip approach. Relative translatory movements up to 8.2 mm mediolaterally and up to 8.8 degrees in rotation were measured. Using a measurement technique in which the calculation of leg length and offset changes is primarily based on a specific realignment of the leg, maximum differences of 1.3 mm for leg length and 1.2 mm for offset were found when comparing the pin-based and pinless methods. Thus, invasive fixation techniques with screws or pins are still the method of choice when standard measurement algorithms for intraoperative leg length and offset measures are used. Though direct translatory and rotational variations between the pinless array and the femoral bone were detected, the pinless array can be used to assess leg length and offset when used with a specific measurement technique that compensates for such variations. (C) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:583-588, 2010
引用
收藏
页码:583 / 588
页数:6
相关论文
共 50 条
  • [1] Clinical Validation of Computer-Assisted Navigation in Total Hip Arthroplasty
    Beaumont, Eric
    Beaumont, Pierre
    Odermat, Daniel
    Fontaine, Isabelle
    Jansen, Herbert
    Prince, Francois
    [J]. ADVANCES IN ORTHOPEDICS, 2011, 2011
  • [2] Pin Site Complications Associated With Computer-Assisted Navigation in Hip and Knee Arthroplasty
    Kamara, Eli
    Berliner, Zachary P.
    Hepinstall, Matthew S.
    Cooper, H. John
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (09): : 2842 - 2846
  • [3] Femoral fracture through a previous pin site after computer-assisted total knee arthroplasty
    Wysocki, Robert W.
    Sheinkop, Mitchell B.
    Virkus, Walter W.
    Della Valle, Craig J.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 462 - 465
  • [4] Quantitative computer-assisted osteodensitometry in total hip arthroplasty
    Pitto, R. P.
    Mueller, L. A.
    Reilly, K.
    Schmidt, R.
    Munro, J.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2007, 31 (04) : 431 - 438
  • [5] Computer-assisted technique to delineate osteolytic lesions around the femoral component in total hip arthroplasty
    Prevrhal, Sven
    Klifa, Catherine S.
    Shepherd, John A.
    Ries, Michael D.
    Genant, Harry K.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (06): : 833 - 838
  • [6] Quantitative computer-assisted osteodensitometry in total hip arthroplasty
    R. P. Pitto
    L. A. Mueller
    K. Reilly
    R. Schmidt
    J. Munro
    [J]. International Orthopaedics, 2007, 31 : 431 - 438
  • [7] Computer-assisted osteodensitometry following total hip arthroplasty
    Reilly, Keryn
    Munro, Jacob
    Pitto, Rocco P.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) : 763 - 768
  • [8] Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty - Reply
    Argenson, Jean-Noel A.
    Parratte, Sebastien
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (08): : 1869 - 1869
  • [9] Comparative repeatability of guide-pin axis positioning in computer-assisted and manual femoral head resurfacing arthroplasty
    Hodgson, A.
    Helmy, N.
    Masri, B. A.
    Greidanus, N. V.
    Inkpen, K. B.
    Duncan, C. P.
    Garbuz, D. S.
    Anglin, C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H7) : 713 - 724
  • [10] Comparative repeatability of guide-pin axis positioning in computer-assisted and manual femoral head resurfacing arthroplasty
    Department of Mechanical Engineering, University of British Columbia, 6250 Applied Sciences Lane, Vancouver
    BC
    V6T 1Z4, Canada
    不详
    不详
    [J]. Proc. Inst. Mech. Eng. Part H J. Eng. Med., 2007, 7 (713-724):