Thermoluminescent materials for medical applications:: LiF:Mg,Ti and LiF:Mg,Cu,P

被引:51
|
作者
Moscovitch, M. [1 ]
Horowitz, Y. S.
机构
[1] Georgetown Univ, Dept Radiat Med, Washington, DC 20057 USA
[2] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
关键词
D O I
10.1016/j.radmeas.2007.01.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Thermoluminescent dosimeters are used in a variety of medical applications including radiation therapy, diagnostic radiology, and radiotherapy mailed dosimetry. For many years LiF:Mg,Ti has been dominating the field, of TL medical dosimetry. In recent years, however, a relatively new material, LiF:Mg,Cu,P, has attracted the attention of the medical dosimetry community and its usefulness in a variety of applications was demonstrated. In this article we discuss and explain in detail the dosimetric properties of these two materials, emphasizing the characteristics that are particularly relevant to medical dosimetry, with special emphasis on the sensitivity (including fading) dose response, and the photon energy dependence. (c) 2007 Published by Elsevier Ltd.
引用
收藏
页码:S71 / S77
页数:7
相关论文
共 50 条
  • [1] Positron annihilation in thermoluminescent materials LiF:Mg, Ti and LiF:Mg, Cu, P and MgSO4
    Deng, Zouping
    Luo, Daling
    Zhu, Ziying
    Zhang, Chunxiang
    Li, Jingde
    He Jishu/Nuclear Techniques, 1998, 21 (02): : 89 - 93
  • [2] A comparative analysis of three thermoluminescent phosphors LiF:Mg,Ti (TLD-100), LiF:Mg,Cu and LiF:Mg,Cu,P
    Srivastava, JK
    Bhatt, BC
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 191 - 194
  • [3] A comparison of the effectiveness of thermoluminescent crystals LiF:Mg,Ti, and LiF:Mg,Cu,P for clinical dosimetry
    Harris, CK
    Elson, HR
    Lamba, MAS
    Foster, AE
    MEDICAL PHYSICS, 1997, 24 (09) : 1527 - 1529
  • [4] The light sensitivity of thermoluminescent materials:: LiF:Mg,Cu,P, LiF:Mg,Ti and Al2O3:C
    Duggan, L
    Budzanowski, M
    Przegietka, K
    Reitsema, N
    Wong, J
    Kron, T
    RADIATION MEASUREMENTS, 2000, 32 (04) : 335 - 342
  • [5] Behaviour of LiF:Mg,Cu,P and LiF:Mg,Ti thermoluminescent detectors for electron doses up to 1 MGy
    Bilski, Pawel
    Obryk, Barbara
    Stuglik, Zofia
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 576 - 578
  • [6] Comparative studies on radioluminescent and thermoluminescent spectra of LiF:Mg,Cu,P and LiF:Mg,Cu,Si
    Tang, K.
    Fan, H.
    Cui, H.
    Zhu, H.
    Liu, Z.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (04) : 459 - 464
  • [7] LIF(MG,TI) THERMOLUMINESCENT PELLETS
    CAMPOS, LL
    RZYSKI, BM
    SUAREZ, AA
    RADIATION PROTECTION DOSIMETRY, 1985, 11 (03) : 189 - 191
  • [8] Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P
    Bilski, P
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 199 - 206
  • [9] Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P
    Bilski, P
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 199 - 206
  • [10] The low energy X-ray response of the LiF:Mg:Cu:P thermoluminescent dosemeter:: a comparison with LiF:Mg:Ti
    Edwards, CR
    Mountford, PJ
    Green, S
    Palethorpe, JE
    Moloney, AJ
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (930): : 543 - 547