Determination of gold in waters by electrothermal atomic absorption spectrometry with preconcentration on a tungsten bar

被引:0
|
作者
Ohta, K
Yokoyama, M
Ogawa, J
Mizuno, T
机构
关键词
electrothermal atomic absorption spectrometry; metallic atomizer; gold; water; adsorption on tungsten bar; preconcentration;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preconcentration of gold in water on tungsten bar followed by electrothermal atomic absorption spectrometry with a molybdenum tube atomizer is described. The optimal immersing time was 15 s. The best pH for gold adsorption was 3. Under optimal conditions, the detection limit was 1.6 pg mL(-1) (3S/N). The effects on the preconcentration of gold by large amounts of concomitants were evaluated. Even though 100 000-fold matrix elements existed in water, the gold absorption signal was not affected by the matrix elements. The method with preconcentration on tungsten bar was applied to the determination of gold in river and sea water.
引用
收藏
页码:22 / 24
页数:3
相关论文
共 50 条
  • [1] Determination of gold in waters by electrothermal atomic absorption spectrometry with preconcentration on a tungsten bar
    Ohta, K.
    Yokoyama, M.
    Ogawa, J.
    Mizuno, T.
    Analusis, 24 (01):
  • [2] Determination of barium in waters by tungsten coil electrothermal atomic absorption spectrometry
    Silva, M.M., 1600, Royal Soc of Chemistry, Letchworth, United Kingdom (09):
  • [3] Determination of nickel in water by electrothermal atomic absorption spectrometry with preconcentration on a tungsten foil
    Ohta, K
    Ishida, K
    Itoh, S
    Kaneco, S
    Mizuno, T
    MIKROCHIMICA ACTA, 1998, 129 (1-2) : 127 - 132
  • [4] Determination of nickel in water by electrothermal atomic absorption spectrometry with preconcentration on a tungsten foil
    Kiyohisa Ohta
    Keita Ishida
    Syn-ichi Itoh
    Satoshi Kaneco
    Takayuki Mizuno
    Microchimica Acta, 1998, 129 : 127 - 132
  • [5] Determination of Nickel in Water by Electrothermal Atomic Absorption Spectrometry with Preconcentration on a Tungsten Foil
    Ohta, Kiyohisa
    Ishida, Keita
    Itoh, Syn-Ichi
    Kaneco, Satoshi
    Mizuno, Takayuki
    Mikrochimica Acta, 1998, 129 (01): : 127 - 132
  • [6] Determination of antimony in waters by electrothermal atomic absorption spectrometry with preconcentration on a tantalum wire
    Amin, N
    Kaneco, S
    Nomura, K
    Suzuki, T
    Ohta, K
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 87 - 91
  • [7] Determination of Antimony in Waters by Electrothermal Atomic Absorption Spectrometry with Preconcentration on a Tantalum Wire
    Md. Nurul Amin
    Satoshi Kaneco
    Ken Nomura
    Tohru Suzuki
    Kiyohisa Ohta
    Microchimica Acta, 2003, 141 : 87 - 91
  • [8] DETERMINATION OF BARIUM IN WATERS BY TUNGSTEN COIL ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    SILVA, MM
    SILVA, RB
    KRUG, FJ
    NOBREGA, JA
    BERNDT, H
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) : 861 - 865
  • [9] Determination of chromium in river waters by electrothermal atomic absorption spectrometry with preconcentration on a tantalum wire
    Amin, MN
    Okada, H
    Itoh, S
    Suzuki, T
    Kaneco, S
    Ohta, K
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (08): : 1130 - 1133
  • [10] On-line coupling of electrochemical preconcentration in tungsten coil electrothermal atomic absorption spectrometry for determination of lead in natural waters
    Barbosa, F
    Krug, FJ
    Lima, EC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (08) : 1155 - 1166