Position control of intravascular Doppler guidewire: Concept of a tracking indicator and its clinical implications

被引:0
|
作者
Jenni, R [1 ]
Buchi, M [1 ]
Jakob, M [1 ]
Ritter, M [1 ]
机构
[1] Univ Zurich Hosp, Div Echocardiog, CH-8091 Zurich, Switzerland
来源
关键词
averaged peak velocity; normalized first Doppler moment;
D O I
10.1002/(SICI)1097-0304(199805)44:1<28::AID-CCD8>3.0.CO;2-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intracoronary Doppler ultrasound guidewires (DGW) utilize a wide ultrasound beam combined with a measurement of the spectral peak velocity to estimate the spatial peak velocity within a blood vessel. However, the spectral peak velocity may underestimate the true spatial peak velocity if the DGW is not properly positioned. The purpose of this study was to find a Doppler-derived parameter that would aid in the optimal positioning of the DGW within the vessel lumen. We studied the relationship between the time-averaged, spectral-peak velocity (APV) and the normalized first Doppler moment (M1/M0) to develop a DGW position indicator and demonstrate its clinical utility. In vitro, heparinized, human whole blood with a hematocrit of 45% was directed from a reservoir via a roller pump into four serially connected straight silicone tubes of known diameter (2.5, 3.0, 3.5, 4.0 mm). A DGW was inserted into the tubes where simultaneous APV and M1/M0 measurements were obtained for flow rates ranging from 49 to 316 ml/min. Optimal positioning of the DGW was identified at the position where maximum APV and M1/M0 were obtained. With optimal positioning the correlation between APV and M1/M0 was good (APV = 1.62 M1/M0 + 5.0; R-2 = 0.98). Importantly, this correlation showed no dependence on the tube diameter. In vivo, in four patients APV and M1/M0 measurements were obtained in 16 coronary artery segments in one left anterior descending, two circumflex, and two right coronary arteries. In 10 vessel segments, there was no discrepancy between the measured and expected M1/M0 after positioning the DGW with help of the Doppler signal quality only. In six vessel segments, repeat DGW positioning using M1/M0 was necessary, yielding an average increase of APV of 20% (7-38%). We conclude that DGW positioning can be optimized using the correlation between APV and M1/M0 as a reference. For any given APV value, there is a corresponding expected value for M1/M0 under the condition of optimal positioning. Any discrepancy between the measured and expected values for M1/M0 then indicates suboptimal positioning. (C) 1998 Wiley-Liss, Inc.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 32 条
  • [1] Optimizing the position of intravascular Doppler guide wires:: Clinical implications of a new tracking indicator
    Büchi, M
    Jakob, M
    Ritter, M
    Jenni, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 19A - 19A
  • [2] Intravascular Imaging of Coronary Calcification and its Clinical Implications
    Mintz, Gary S.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (04) : 461 - 471
  • [3] The concept of severe hypertriglyceridemia and its implications in clinical practice
    Pinto Sala, Xavier
    Esteve Luque, Virginia
    CLINICA E INVESTIGACION EN ARTERIOSCLEROSIS, 2018, 30 (05): : 193 - 196
  • [4] The Development of the Mucosal Concept in Chronic Rhinosinusitis and Its Clinical Implications
    Huang, Yanran
    Zhang, Nan
    Xu, Zhaofeng
    Zhang, Luo
    Bachert, Claus
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2022, 10 (03): : 707 - 715
  • [5] Tracking of cardiovascular risk factors and its implications for clinical trials
    Ulmer, H
    CONTROLLED CLINICAL TRIALS, 2003, 24 : 193S - 193S
  • [6] Clinical Implications of Distal Embolization During Coronary Interventional Procedures in Patients With Acute Myocardial Infarction Quantitative Study With Doppler Guidewire
    Okamura, Atsunori
    Ito, Hiroshi
    Iwakura, Katsuomi
    Kurotobi, Toshiya
    Koyama, Yasushi
    Date, Motoo
    Higuchi, Yoshiharu
    Inoue, Koichi
    Fujii, Kenshi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) : 268 - 276
  • [7] Transcranial Doppler sonography during interictal periods of migraine: Its clinical implications
    Chung, CS
    Lee, EJ
    Lee, KH
    STROKE, 1996, 27 (04) : 797 - 797
  • [8] Islamic locus of control concept and its implications on individual behavior in organizations
    Zakiy, Muhammad
    Santoso, Claudius Budi
    Rosari, Reni
    Tjahjono, Heru Kurnianto
    JOURNAL OF ISLAMIC ACCOUNTING AND BUSINESS RESEARCH, 2024,
  • [9] VERTICAL CONTROL - MULTIFACTORIAL PROBLEM AND ITS CLINICAL IMPLICATIONS
    SPYROPOULOS, MN
    ASKARIEH, M
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1976, 70 (01) : 70 - 80
  • [10] Verification of the Output Signal Change of Control Rod Position Indicator at the End of Its Life Time
    Yu, Je-Yong
    Kim, Ji-Ho
    Huh, Hyung
    Choi, Myong-Hwan
    Sohn, Dong-Seong
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2010, VOL 9, 2010, : 1 - 5