Behavior of Auxetic Steel Wire RC Columns Exposed to Elevated Temperature

被引:7
|
作者
Al-Rousan, Rajai Z. [1 ]
机构
[1] Jordan Univ Sci & Technol, Dept Civil Engn, Irbid, Jordan
关键词
Thermal Shock; Structural Strength; Axial Strength; Auxetic Steel Mesh; Column; HIGH-STRENGTH CONCRETE; MECHANICAL-PROPERTIES; FLEXURAL BEHAVIOR; AXIAL BEHAVIOR; ROPE; STRIPS;
D O I
10.1590/1679-78256422
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Twenty-four rectangular RC column specimens, constructed at 1/3 scale, were tested under axial loading to investigate the use of ASWM (one, two, three, four, and five layers) exposed to elevated temperatures. Six of the column specimens were subjected to laboratory temperature (control or un-damaged specimens) of 23 degrees C. Eighteen of the column specimens were subjected to elevated temperatures (six columns at 250 degrees C, six columns at 500 degrees C, and six columns at 750 degrees C) for 2 hr. The obtained results clearly showed that each axial load resistance, toughness, and stiffness were all negatively affected by escalated temperature degrees. Also, the confinement effectiveness in terms of the ultimate load was decreased with the increase in concrete compressive strength (un-damaged). The number of ASWM layers significantly influenced the ductility, energy absorption, and ultimate load improvement percentage. The number of the ASWM layers considerably enhanced the ductility up to a certain number of erected layers; however, adding more layers had no apparent effect.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [1] Behaviour of thermally shocked RC columns internally confined by auxetic steel wire mesh
    Al-Rousan, Rajai Z.
    Alnemrawi, Bara'a R.
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2023, 177 (10) : 864 - 877
  • [2] The impact of the welded wire mesh as internal reinforcement on the flexural behavior of RC beams exposed to elevated temperature
    Al-Rousan, Rajai Z.
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2021, 15
  • [3] Structural behavior of centrally loaded steel columns at elevated temperature
    Yang, Kuo-Chen
    Hsu, Rejia
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (10-11) : 2062 - 2068
  • [4] Influence of load induced thermal strain on axial compressive RC columns after exposed to elevated temperature
    Zhou, Xin-Gang
    Zhang, John
    [J]. Xiangtan Daxue Ziran Kexue Xuebao, 2002, 24 (02):
  • [5] Investigation the behavior of LWAC encased steel columns after exposure to elevated temperature
    Al-Talqani, Noor Al-Huda
    Al-Thairy, Haitham
    [J]. STRUCTURAL CONCRETE, 2024,
  • [6] BEHAVIOR OF STEEL COLUMNS AT ELEVATED-TEMPERATURES
    POH, KW
    BENNETTS, ID
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (04): : 676 - 684
  • [7] Coating protection of loaded RC columns to resist elevated temperature
    Hodhod, O. A.
    Rashad, A. M.
    Abdel-Razek, M. M.
    Ragab, A. M.
    [J]. FIRE SAFETY JOURNAL, 2009, 44 (02) : 241 - 249
  • [8] Investigation on Mechanical Behavior of I-Section Steel Columns After Elevated Temperature
    Chen, Yu
    Xie, Wentao
    Han, Shaohua
    Wang, Kai
    [J]. FIRE TECHNOLOGY, 2018, 54 (02) : 503 - 529
  • [9] Investigation on Mechanical Behavior of I-Section Steel Columns After Elevated Temperature
    Yu Chen
    Wentao Xie
    Shaohua Han
    Kai Wang
    [J]. Fire Technology, 2018, 54 : 503 - 529
  • [10] Testing on Axial Compression of Damaged RC Columns Reinforced by Winding Steel Wire
    Si Jianhui
    Li Liang
    Liu Maoshe
    [J]. INTERNATIONAL SYMPOSIUM ON MATERIALS APPLICATION AND ENGINEERING (SMAE 2016), 2016, 67