In situ Nd isotope analyses in geological materials with signal enhancement and non-linear mass dependent fractionation reduction using laser ablation MC-ICP-MS

被引:97
|
作者
Xu, Lei [1 ]
Hu, Zhaochu [1 ]
Zhang, Wen [1 ]
Yang, Lu [2 ]
Liu, Yongsheng [1 ]
Gao, Shan [1 ]
Luo, Tao [1 ]
Hu, Shenghong [1 ]
机构
[1] China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
[2] Natl Res Council Canada, Measurement Sci & Stand, Ottawa, ON K1A 0R6, Canada
关键词
U-PB GEOCHRONOLOGY; SM-ND; RATIO ANALYSIS; NEODYMIUM; PRECISE; ZIRCON; HF; SPECTROMETRY; SYSTEMATICS; NITROGEN;
D O I
10.1039/c4ja00243a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To improve the precision and accuracy of in situ Nd isotope analyses in geological samples, high analytical sensitivity and minimized non-linear mass dependent fractionation are desirable. In this study, we investigated the effects of three different cone combinations and the addition of N-2 with the guard electrode, either grounded or floating, on the performance of Nd isotope analyses. Signal enhancements (2.5-3 folds) were observed for the Jet sample cone + X skimmer cone and for the standard sample cone + X skimmer cone, which were compared to those of the standard sample cone + H skimmer cone with the addition of N-2 at 3 or 6 ml min(-1). The influence of a guard electrode on the LA-MC-ICP-MS sensitivity was minimal for dry plasma conditions but became significant in the presence of N-2. The addition of 3 or 6 ml min(-1) N-2 into the carrier gas increased the sensitivity for Nd by a factor of 1.6 with the GE-on mode for the Jet sample cone + X skimmer cone. However, in the GE-off mode, the addition of 2-3 ml min(-1) N-2 decreased the signal intensity of Nd by a factor of two to three. The makeup gas flow rate was found to have a significant effect on the mass bias stability of Nd isotopes, and this effect was different for different cone combinations. To stabilize the mass bias, measurements at elevated makeup gas flow rates was required for the combination of the X skimmer cone with the standard sample cone or Jet sample cone, at the expense of sensitivity. In notable contrast, the mass bias was stable for the combination of the standard sample cone and H skimmer cone under their corresponding optimum makeup gas flow rates. However, we found that the neodymium isotopes exhibited a large non-linear component at elevated makeup gas flow rates that could not be corrected by the accepted mass fractionation laws. The addition of 3-6 ml min(-1) nitrogen to the central gas flow in laser ablation MC-ICP-MS was found to not only significantly enlarge the mass bias stability zone, but also to suppress the non-linear mass dependent fractionation for the combination of X skimmer cone with Jet sample cone or standard sample cone. The accuracy and precision of the developed analytical method for Nd isotope using Jet sample cone + X skimmer cone with the addition of nitrogen has been demonstrated by analyzing a series of reference glasses (JNdi-1 glass, LREE glass, NIST 610) and minerals (apatite, monazite and titanite). Results obtained for Nd-143/Nd-144 ratios in these reference materials are in excellent agreement with published values, demonstrating the capability of the developed analytical method to be an important tool for providing high-quality in situ Nd isotope data in geological samples.
引用
收藏
页码:232 / 244
页数:13
相关论文
共 50 条
  • [1] In situ Nd isotope analyses in geological materials with signal enhancement and non-linear mass dependent fractionation reduction using laser ablation MC-ICP-MS
    State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan
    430074, China
    不详
    ON
    K1A 0R6, Canada
    J Anal At Spectrom, 1 (232-244):
  • [2] In situ Nd isotopic analysis of geological materials by laser ablation MC-ICP-MS
    Foster, GL
    Vance, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (03) : 288 - 296
  • [3] In situ Nd isotopic analysis of geological materials by laser ablation MC-ICP-MS
    Foster, Gavin L.
    Vance, Derek
    Journal of Analytical Atomic Spectrometry, 2006, 21 (03): : 288 - 296
  • [4] In Situ Carbon Isotope Analysis by Laser Ablation MC-ICP-MS
    Chen, Wei
    Lu, Jue
    Jiang, Shao-Yong
    Zhao, Kui-Dong
    Duan, Deng-Fei
    ANALYTICAL CHEMISTRY, 2017, 89 (24) : 13415 - 13421
  • [5] Effects of the sampling interface in MC-ICP-MS: Relative elemental sensitivities and non-linear mass dependent fractionation of Nd isotopes
    Newman, Karla
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (01) : 63 - 70
  • [6] In-situ Fe isotopic fractionation determination by laser ablation MC-ICP-MS
    Tunheng, A
    Hirata, T
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A381 - A381
  • [7] Synthesis of molybdenite reference materials for in situ molybdenum and sulfur isotope measurement using laser ablation MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Lv, Nan
    Yang, Wenqiang
    Nie, Xiaojuan
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (06) : 1503 - 1513
  • [8] 785 nm femtosecond laser ablation for improved precision and reduction of interferences in Sr isotope analyses using MC-ICP-MS
    Yang, Zhaoping
    Fryer, Brian J.
    Longerich, Henry P.
    Gagnon, Joel E.
    Samson, Iain M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (02) : 341 - 351
  • [9] Preparation of standards for in situ sulfur isotope measurement in sulfides using femtosecond laser ablation MC-ICP-MS
    Chen, Lu
    Chen, Kaiyun
    Bao, Zhian
    Liang, Peng
    Sun, Tiantian
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 107 - 116
  • [10] UV-femtosecond laser ablation MC-ICP-MS for in situ analyses of Si isotopes
    Chmeleff, Jerome
    Horn, Ingo
    Steinhoefel, Grit
    Von Blanckenburg, Friedhelm
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A172 - A172