摘要
Objectives: Transcranial magnetic stimulation (TMS) has been employed in patients with an implanted deep brain Stimulation (DBS) device. We investigated the safety of TMS using Simulation models with an implanted DBS device. Methods: The DBS lead was inserted into plastic phantoms filled with dilute gelatin showing impedance similar to that of human brain. TMS was performed with three different types of magnetic coil. During TMS (I) electrode movement, (2) temperature change around the lead, and (3) TMS-induced current in various Situations were observed. The amplitude and area of each evoked current were measured to calculate charge density of the evoked current. Results: There was no movement or temperature increase during 0.2 Hz repetitive TMS with 100% stimulus intensity for 1 h. The size of evoked current linearly increased with TMS intensity. The maximum charge density exceeded the safety limit of 30 mu C/cm(2)/phase during Stimulation above the loops of the lead with intensity over 50% using a figure-eight coil. Conclusions: Strong TMS on the looped DBS leads should not be administered to avoid electrical tissue injury. Subcutaneous lead position should be paid enough attention for forthcoming Situations during surgery. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 50 条
  • [1] Safety Study of Combination Treatment: Deep Brain Stimulation and Transcranial Magnetic Stimulation
    Magsood, Hamzah
    Syeda, Farheen
    Holloway, Kathryn
    Carmona, Ivan C.
    Hadimani, Ravi L.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2020, 14
  • [2] Safety of transcranial magnetic stimulation in patients with implanted deep brain stimulators
    Kumar, R
    Chen, R
    Ashby, P
    MOVEMENT DISORDERS, 1999, 14 (01) : 157 - 158
  • [3] Safety of transcranial magnetic stimulation for the newer generation of deep brain stimulators
    Kuehn, Andrea A.
    Huebl, Julius
    PARKINSONISM & RELATED DISORDERS, 2011, 17 (08) : 647 - 648
  • [4] Brain stimulation procedures. Transcranial magnetic stimulation, magnetic seizure therapy and deep brain stimulation
    Schlaepfer, T. E.
    Kayser, S.
    NERVENARZT, 2012, 83 (01): : 95 - 103
  • [5] Safety of Transcranial Magnetic and Transcranial Direct Current Brain Stimulation
    Paulus, Walter
    KLINISCHE NEUROPHYSIOLOGIE, 2017, 48 (01) : 17 - 20
  • [6] Transcranial magnetic stimulation and deep brain stimulation as augmentation method for depressions
    Schlaepfer, Thomas
    NERVENARZT, 2007, 78 : 107 - 107
  • [7] Transcranial Magnetic Stimulation and Deep Brain Stimulation in the Treatment of Alcohol Dependence
    Alba-Ferrara, Lucia M.
    Fernandez, Francisco
    Salas, Ramiro
    de Erausquin, Gabriel A.
    ADDICTIVE DISORDERS & THEIR TREATMENT, 2014, 13 (04): : 159 - 169
  • [8] Safety of transcranial direct current stimulation in a patient with deep brain stimulation electrodes
    Iannone, Aline
    Allam, Nasser
    Brasil-Neto, Joaquim P.
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2019, 77 (03) : 174 - 178
  • [9] New Designs for Deep Brain Transcranial Magnetic Stimulation
    Williams, P. I.
    Marketos, P.
    Crowther, L. J.
    Jiles, D. C.
    IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (03) : 1171 - 1178
  • [10] Safety of Transcranial Magnetic Stimulation in an Obsessive-Compulsive Disorder Patient With Deep Brain Stimulation A Case Report
    Miron, Jean-Philippe
    Jodoin, Veronique Desbeaumes
    Fournier-Gosselin, Marie-Pierre
    Lesperance, Paul
    JOURNAL OF ECT, 2019, 35 (01) : E7 - E8