Enhancement of a 252Cf-based neutron beam via subcritical multiplication for neutron capture therapy

被引:0
|
作者
Wang, CK [1 ]
Zino, JF [1 ]
Kessler, G [1 ]
机构
[1] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA 30332 USA
关键词
Monte Carlo; neutron capture therapy; subcritical multiplication; Cf-252;
D O I
10.1016/S0969-8043(00)00237-2
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Previous studies indicated that an epithermal-neutron beam based on bare Cf-252 is not feasible for neutron capture therapy (NCT). It was reported that a clinically useful epithermal-neutron beam requires a minimum of 1.0 g of Cf-252, which is more than twice the US current annual supply. However, it was reasoned that the required quantity of Cf-252 could be dramatically reduced when used with a subcritical multiplying assembly (SMA), This reasoning is based on the assumption that the epithermal-neutron beam intensity for NCT is directly proportional to the fission neutron population, and that the neutron multiplying factor of the SMA can be estimated by 1/(1 - k(eff)). We have performed detailed Monte Carlo calculations to investigate the validity of the above reasoning. Our results show that 1/(1 - k(eff)) grossly overestimates the beam enhancement factor for NCT. For example, Monte Carlo calculations predict a beam enhancement factor of 6.0 for an optimized SMA geometry with k(eff) = 0.968. This factor is much less than 31 predicted by 1/(1 - k(eff)). The overestimation is due to the fact that most of the neutrons produced in the SMA are self-shielded, whereas self-shielding is negligible in a bare Cf-252 source. Since the beam intensity of a 0.1 g Cf-252 With the optimized SMA enhancement is still more than an order of magnitude too low compared to the existing reactor beams, we conclude that the enhancement via an SMA for a Cf-252-based epithermal-neutron beam is inadequate for NCT. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:811 / 814
页数:4
相关论文
共 50 条
  • [1] Gamma-ray and neutron shielding features for some fast neutron moderators of interest in 252Cf-based boron neutron capture therapy
    Elsheikh, Nassreldeen A. A.
    APPLIED RADIATION AND ISOTOPES, 2020, 156
  • [2] CF-252 NEUTRON-CAPTURE THERAPY AND TELETHERAPY
    MARUYAMA, Y
    WIERZBICKI, J
    ASHTARI, M
    YAES, RJ
    BEACH, JL
    YANCH, J
    ZAMENHOF, R
    SCHROY, CB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (01): : 255 - 255
  • [3] BORON NEUTRON-CAPTURE ENHANCEMENT OF CF-252 BRACHYTHERAPY
    BEACH, JL
    SCHROY, CB
    ASHTARI, M
    HARRIS, MR
    MARUYAMA, Y
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1421 - 1427
  • [4] INCREASED NEUTRON CAPABILITY OF CF-252 WITH A SUBCRITICAL ASSEMBLY
    WATANABE, T
    MILLER, LG
    MATERIALS EVALUATION, 1970, 28 (09) : A28 - &
  • [5] OPTIMUM DESIGN OF A SUBCRITICAL NEUTRON IRRADIATOR USING CF-252 NEUTRON SOURCES
    LEE, BW
    LEVINE, SH
    JESTER, WA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 (OCT27): : 47 - 48
  • [6] Measurement of dose enhancement by neutron capture of boron in 252Cf interstitial brachytherapy
    Abd El-Hafez, AI
    Eissa, HM
    Eman, SA
    Fadel, MA
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 441 - 444
  • [7] Optimised the Neutron Beam for a Transportable BNCT System Based on 252Cf Neutron Source
    Fantidis, J.G.
    Nicolaou, G.
    Parousis, D.
    Kogia, F.
    Journal of Engineering Science and Technology Review, 2020, (Special Issue) : 107 - 111
  • [8] ENHANCEMENT OF THE EPITHERMAL NEUTRON BEAM USED FOR BORON NEUTRON-CAPTURE THERAPY
    LIU, HYB
    BRUGGER, RM
    GREENBERG, DD
    RORER, DC
    HU, JP
    HAUPTMAN, HM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1149 - 1156
  • [9] Characterization of a modified fast neutron beam for boron neutron capture enhancement of fast neutron therapy
    Burmeister, J
    Kota, C
    Yudelev, M
    Maughan, RL
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 709 - 713
  • [10] STUDY OF AN OPTIMUM DESIGN FOR SUBCRITICAL NEUTRON MULTIPLIERS USING CF-252 NEUTRON SOURCES
    LEE, BWT
    LEVINE, SH
    JESTER, WA
    NUCLEAR TECHNOLOGY, 1979, 44 (01) : 177 - 187