Study of ageing and gain limits of microstrip gas chambers at high rates

被引:12
|
作者
Boimska, B [1 ]
Bouclier, R
Capeans, M
Claes, S
Dominik, W
Hoch, M
Million, G
Ropelewski, L
Sauli, F
Sharma, A
Shekhtman, L
Van Doninck, W
Van Lancker, L
机构
[1] CERN, Geneva, Switzerland
[2] Inter Univ Inst High Energies ULB VUB, Brussels, Belgium
[3] Univ Haute Alsace, GRPHE, Mulhouse, France
[4] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
关键词
D O I
10.1016/S0920-5632(97)00609-9
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The CMS experiment comprises MSGCs as one of the key detection elements for high luminosity tracking at LHC. In addition to the high dose rate of 10 mC/year per cm of strip, these detectors have to survive the hostile presence of highly ionizing particles, neutrons low energy gammas and hadrons. In this report we present the results of systematic tests on maximum safe operational gain limits in MSGCs before the discharge. Long term ageing tests performed on prototype open 'banana' modules envisaged to be arranged around the interaction region in the forward part of the CMS tracker show no evidence of gain dop up to equivalent similar to 10 years of LHC operation A comparison is made between argon and neon gas mixtures with DME in equal proportions by investigating long term irradiation effects on chamber operation by introducing controlled and reproducible pollution in the gas lines.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 50 条
  • [1] Gain stability of microstrip gas chambers with high resistivity substrates
    Fang, R
    Geist, W
    Brom, JM
    Bergdolt, A
    Riester, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (03): : 439 - 442
  • [2] Ageing of microstrip gas chambers: Problems and solutions
    Bouclier, R
    Capeans, M
    Garbatos, C
    Manzin, G
    Million, G
    Ropelewski, L
    Sauli, F
    Shekhtman, L
    Silander, K
    RopelewskiTemmel, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (2-3): : 289 - 319
  • [3] Ageing of microstrip gas chambers: Problems and solutions
    Bouclier, R.
    Capeans, M.
    Garbatos, C.
    Manzin, G.
    Million, G.
    Ropelewski, L.
    Sauli, F.
    Shekhtman, L.
    Silander, K.
    Ropelewski-Temmel, T.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 381 (2-3): : 289 - 319
  • [4] Operation of high rate microstrip gas chambers
    Barr, A
    Boimska, B
    Bouclier, R
    Capeans, M
    Dominik, W
    Manzin, G
    Million, G
    Hoch, M
    Ropelewski, L
    Sauli, F
    Sharma, A
    NUCLEAR PHYSICS B, 1998, : 264 - 269
  • [5] GAS MICROSTRIP CHAMBERS
    BARASCH, EF
    BOWCOCK, TJV
    DEMROFF, HP
    ELLIOTT, SM
    HOWE, MR
    LEE, B
    MAZUMDAR, TK
    MCINTYRE, PM
    PANG, Y
    SMITH, DD
    WAHL, J
    WU, Y
    YUE, WK
    GAEDKE, RM
    VANSTRAELEN, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3): : 170 - 176
  • [6] Study of thin substrates for microstrip gas chambers
    Schnidt, S.
    Werthenbach, U.
    Zech, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A337 (2-3) : 382 - 386
  • [7] Study of AlN coatings for microstrip gas chambers
    Buzulutskov, A
    Bondar, A
    Mironenko, L
    Nagaslaev, V
    Shekhtman, L
    Tatarinov, A
    Kascheev, S
    Belyanin, A
    Blaut-Blachev, A
    Bouilov, L
    Spitsyn, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 33 - 36
  • [8] A STUDY OF BREAKDOWN IN MICROSTRIP GAS-CHAMBERS
    DUERDOTH, I
    SNOW, S
    THOMPSON, R
    LUMB, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 356 - 360
  • [9] High rate tests of microstrip gas chambers for CMS
    Malina, R
    Bastie, C
    Bell, B
    Bellazzini, R
    Bozzo, M
    Brand, C
    Brez, A
    Caner, A
    Cattai, A
    Chorowicz, V
    Contardo, D
    Latronico, L
    Lumb, N
    Magazzú, C
    Martin, J
    Massai, M
    Mirabito, L
    Morelli, A
    Raffo, R
    Rolandi, L
    Smadja, G
    Spandre, G
    Spezziga, M
    Tsirou, A
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 80 - 83
  • [10] STUDY OF THIN SUBSTRATES FOR MICROSTRIP GAS-CHAMBERS
    SCHMIDT, S
    WERTHENBACH, U
    ZECH, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 382 - 386