Round window membrane motion with air conduction and bone conduction stimulation

被引:49
|
作者
Stenfelt, S [1 ]
Hato, N
Goode, RL
机构
[1] Chalmers Univ Technol, Dept Signals & Syst, SE-41296 Gothenburg, Sweden
[2] Stanford Univ, Med Ctr, Div Otolaryngol Head & Neck Surg, Stanford, CA 94305 USA
关键词
round window; vibration pattern; air conduction; bone conduction; middle ear reconstruction;
D O I
10.1016/j.heares.2004.07.008
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
The vibration patterns of the round window (RW) membrane in human cadaver temporal bone specimens were assessed by measurements of the velocity of reflective targets placed on the RW membrane with an approximate spacing of 0.2 mm. The velocity was measured in the frequency range 0.1-10 kHz by a laser Doppler vibrometer in four specimens with air conduction (AC) stimulation and in four specimens with bone conduction (BC) stimulation. The response pattern was investigated by analyzing the velocity response of all targets on the RW membrane, by making iso-amplitude and iso-phase contour plots of the membrane surface, and by creating animations of the surface vibration at several frequencies. Similar response pattern was found with AC and BC stimulations. At frequencies below 1.5 kHz, the RW membrane vibrates nearly as a whole in an in-and-out motion and above 1.5 kHz, the membrane moves primarily in two sections that vibrate with approximately 180degrees difference. Indication of some traveling wave motion of the RW membrane at those frequencies was also found. At higher frequencies, above 3 kHz, the membrane motion is complex with a mixture of modal and traveling wave motion. An increase of the stimulation level did not alter the vibration pattern; it only gave an increase of the RW membrane vibration amplitude corresponding to the increase in stimulation. When the mode of stimulation at the oval window was altered, by the insertion of a 0.6 mm piston, the vibration pattern of the RW membrane changed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 24
页数:15
相关论文
共 50 条
  • [1] The impact of round window reinforcement on middle and inner ear mechanics with air and bone conduction stimulation
    Geerardyn, Alexander
    Wils, Irina
    Putzeys, Tristan
    Fierens, Guy
    Wouters, Jan
    Ab, Nicolas Verhaert
    HEARING RESEARCH, 2024, 450
  • [2] Round Window Membrane Motion Induced by Bone Conduction Stimulation at Different Excitation Sites: Methodology of Measurement and Data Analysis in Cadaver Study
    Kwacz, Monika
    Niemczyk, Kazimierz
    Wysocki, Jaroslaw
    Lachowska, Magdalena
    Borkowski, Pawel
    Malkowska, Maria
    Sokolowski, Jacek
    EAR AND HEARING, 2019, 40 (06): : 1437 - 1444
  • [3] Middle ear ossicles motion at hearing thresholds with air conduction and bone conduction stimulation
    Stenfelt, S
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (05): : 2848 - 2858
  • [4] Middle ear ossicles motion at hearing thresholds with air conduction and bone conduction stimulation
    Stenfelt, Stefan
    Journal of the Acoustical Society of America, 2006, 119 (05): : 2848 - 2858
  • [5] Fluid volume displacement at the oval and round windows with air and bone conduction stimulation
    Stenfelt, S
    Hato, N
    Goode, RL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (02): : 797 - 812
  • [6] Round Window Occlusion Affects Bone Conduction in Cadaver Heads
    Chen, Keguang
    Lyu, Huiying
    Yin, Dongming
    Yang, Lin
    Zhang, Tianyu
    Dai, Peidong
    OTOLOGY & NEUROTOLOGY, 2018, 39 (07) : e513 - e517
  • [7] The floating mass transducer at the round window: Direct transmission or bone conduction?
    Arnold, Andreas
    Kompis, Martin
    Candreia, Claudia
    Pfiffner, Flurin
    Haeusler, Rudolf
    Stieger, Christof
    HEARING RESEARCH, 2010, 263 (1-2) : 120 - 127
  • [8] Making sense of oval and round window volume displacement asymmetry in bone conduction: A third window near the round window?
    Kim, Namkeun
    Homma, Kenji
    Puria, Sunil
    Steele, Charles R.
    HEARING RESEARCH, 2010, 263 (1-2) : 251 - 252
  • [9] Retrospective audiological analysis of bone conduction versus round window vibratory stimulation in patients with mixed hearing loss
    Mojallal, Hamidreza
    Schwab, Burkard
    Hinze, Anna-Lena
    Giere, Thomas
    Lenarz, Thomas
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (06) : 391 - 400
  • [10] AIR CONDUCTION AND BONE CONDUCTION HEARING AIDS
    AIKEN, RB
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1945, 127 (15): : 1024 - 1024