Selective removal of interference signals for near-infrared spectra of biomedical samples by using region orthogonal signal correction

被引:24
|
作者
Kasemsumran, S
Du, YP
Maruo, K
Ozaki, Y
机构
[1] Kwansei Gakuin Univ, Sch Sci & Technol, Dept Chem, Sanda, Hyogo 6691337, Japan
[2] Kwansei Gakuin Univ, Sch Sci & Technol, Res Ctr Near Infrared Spect, Sanda, Hyogo 6691337, Japan
[3] Shandong Univ Technol, Col Chem Engn, Zibo 255000, Peoples R China
[4] Matsushita Elect Ind Co Ltd, Kadoma, Osaka 5718686, Japan
关键词
near-infrared spectroscopy; glucose; albumin; cholesterol; triglyceride; moving window partial least squares regression; searching combination moving window partial least squares; orthogonal signal correction; region orthogonal signal correction;
D O I
10.1016/j.aca.2004.09.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New approach for chemometrics algorithm named region orthogonal signal correction (ROSC) has been introduced to improve the predictive ability of PLS models for biomedical components in blood serum developed from their NIR spectra in the 1280-1849 nm region. Firstly, a moving window partial least squares regression (MWPLSR) method was employed to locate the region due to water as a region of interference signals and to find the informative regions of glucose, albumin, cholesterol and triglyceride from NIR spectra of bovine serum samples. Next, a novel chemometrics method named searching combination moving window partial least squares (SCMWPLS) was used to optimize those informative regions. Then, the specific regions that contained the information of water, glucose, albumin, cholesterol and triglyceride were obtained. When an interested component in the bovine serum solution, such as glucose, albumin, cholesterol or triglyceride is being an analyte, the other three interests and water are considered as the interference factors. Thus, new approach for ROSC has employed for each specific region of interference signal to calculate the orthogonal components to the concentrations of analyte that were removed specifically from the NIR spectra of bovine serum in the region of 1280-1849 nm and the highest interference signal for model of analyte will be revealed. The comparison of PLS results for glucose, albumin, cholesterol and triglyceride built by using the whole region of original spectra and those developed by using the optimized regions suggested by SCMWPLS of original spectra, spectra treated OSC for orthogonal components of 1-3 and spectra treated ROSC using selected removing the highest interference signals from the spectra for orthogonal components of 1-3 are reported. It has been found that new approach of ROSC to remove the highest interference signal located by SCMWPLS improves of the performance of PLS modeling, yielding the lower RMSECV and smaller number of PLS factors. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 42 条
  • [1] Removal of Interference Signals Due to Water from in vivo Near-Infrared (NIR) Spectra of Blood Glucose by Region Orthogonal Signal Correction (ROSC)
    Yi Ping Du
    Yi Zeng Liang
    Sumaporn Kasemsumran
    Katsuhiko Maruo
    Yukihiro Ozaki
    [J]. Analytical Sciences, 2004, 20 : 1339 - 1345
  • [2] Removal of interference signals due to water from in vivo near-infrared (NIR) spectra of mood glucose by region orthogonal signal correction (ROSC)
    Du, YP
    Liang, YZ
    Kasemsumran, S
    Maruo, K
    Ozaki, Y
    [J]. ANALYTICAL SCIENCES, 2004, 20 (09) : 1339 - 1345
  • [3] Orthogonal signal correction of near-infrared spectra
    Wold, S
    Antti, H
    Lindgren, F
    Öhman, J
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 44 (1-2) : 175 - 185
  • [4] Background correction in near-infrared spectra of plant extracts by orthogonal signal correction
    瞿海斌
    欧丹林
    程翼宇
    [J]. Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2005, (08) : 838 - 843
  • [5] Background correction in near-infrared spectra of plant extracts by orthogonal signal correction
    Qu Hai-bin
    Ou Dan-lin
    Cheng Yi-yu
    [J]. Journal of Zhejiang University Science B, 2005, 6 (8): : 838 - 843
  • [6] Background correction in near-infrared spectra of plant extracts by orthogonal signal correction
    Qu, Hai-Bin
    Ou, Dan-Lin
    Cheng, Yi-Yu
    [J]. Journal of Zhejiang University: Science, 2005, 6 B (08): : 838 - 843
  • [7] Factor selection strategies for orthogonal signal correction applied to calibration of near-infrared spectra
    Yee, NG
    Coghill, GG
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 67 (02) : 145 - 156
  • [8] Orthogonal signal correction of potato crisp near infrared spectra
    Yee, NG
    Coghill, GG
    [J]. JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS, 2003, 34 (05): : 563 - 574
  • [9] Transfer of multivariate calibrations between four near-infrared spectrometers using orthogonal signal correction
    Woody, NA
    Feudale, RN
    Myles, AJ
    Brown, SD
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (09) : 2595 - 2600
  • [10] Interference correction by extracting the information of interference dominant regions: Application to near-infrared spectra
    Bi, Yiming
    Tang, Liang
    Shan, Peng
    Xie, Qiong
    Hu, Yong
    Peng, Silong
    Tan, Jie
    Li, Changwen
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 129 : 542 - 550