Accuracy of Ultrasound in the Detection of Inflow Stenosis of Arteriovenous Fistulae: Results of a Prospective Study

被引:14
|
作者
Salman, Loay [1 ]
Ladino, Marco [1 ]
Alex, Manju [1 ]
Dhamija, Rajiv [1 ]
Merrill, Donna [1 ]
Lenz, Oliver [1 ]
Contreras, Gabriel [1 ]
Asif, Arif [1 ]
机构
[1] Univ Miami, Sch Med, Dept Med, Div Nephrol,Sect Intervent Nephrol, Miami, FL 33136 USA
关键词
FAILURE; GRAFTS;
D O I
10.1111/j.1525-139X.2009.00693.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
While vascular ultrasound (US) has been highlighted to detect vascular access stenosis, its accuracy in the identification of inflow stenosis (IS) (anastomosis and/or juxta-anastomotic area) compared with the gold standard ( angiography) has not been evaluated. One hundred three consecutive fistulae referred for interventions were included in this study. Preprocedure US of inflow segment was performed. Angiography from the feeding artery to the right atrium was then conducted. US comparison to angiography in the detection of IS ( anastomosis and/or juxta-anastomotic area) was evaluated. Additionally, comparison of US to angiography in the assessment of juxta-anastomotic and anastomotic stenosis was reported separately. Data from 103 patients were available for analysis. Overall, US was negative for IS in 52 cases. Of these, 47 did not show a lesion on angiography. Only five cases demonstrated a stenosis on angiography. Fifty-one cases had IS by US, 50 were confirmed by angiography while one case did not show a lesion on angiography. Consequently, US had a sensitivity of 91%, specificity of 98%, and positive and negative predictive values were 98% and 90%, respectively. The sensitivity, specificity, negative, and positive predictive values for juxta-anastomotic and anastomotic lesions evaluated separately were 92%, 98%, 92%, 98% and 79%, 100%, 95%, 100%, respectively. Linear regression analysis showed a significant positive correlation between US and angiography for anastomotic (r(2) = 0.71, p < 0.0001; slope = 0.63 +/- 0.098 and intercept = 24 +/- 6) and juxta-anastomotic stenosis (r(2) = 0.71, p < 0.0001; slope = 0.68 +/- 0.060 and intercept = 23 +/- 4). These results reveal that US has a high degree of accuracy in the detection of IS.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 50 条
  • [1] Percutaneous management of perianastomotic stenosis in arteriovenous fistulae: Results of a prospective study
    Asif, A.
    Lenz, O.
    Merrill, D.
    Cherla, G.
    Cipleu, C. D.
    Ellis, R.
    Francois, B.
    Epstein, D. L.
    Pennell, P.
    [J]. KIDNEY INTERNATIONAL, 2006, 69 (10) : 1904 - 1909
  • [2] Inflow stenosis in arteriovenous fistulas and grafts: A rnulticenter, prospective study
    Asif, A
    Gadalean, FN
    Merrill, D
    Cherla, G
    Cipleu, CD
    Epstein, DL
    Roth, D
    [J]. KIDNEY INTERNATIONAL, 2005, 67 (05) : 1986 - 1992
  • [3] Stenosis Detection Algorithm for Screening of Arteriovenous Fistulae
    Gram, Mikkel
    Olesen, Jens Tranholm
    Riis, Hans Christian
    Selvaratnam, Maiuri
    Meyer-Hofmann, Helmut
    Pedersen, Birgitte Bang
    Christensen, Jeppe Hagstrup
    Struijk, Johannes
    Schmidt, Samuel Emil
    [J]. 15TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS (NBC 2011), 2011, 34 : 241 - +
  • [4] Hemodynamically significant arterial inflow stenosis in dysfunctional hemodialysis arteriovenous fistulae and grafts
    Wu, Steven
    Joe, Jennifer M.
    Covarrubias, Diego A.
    Kalva, Sanjeeva P.
    [J]. JOURNAL OF VASCULAR ACCESS, 2012, 13 (04): : 452 - 458
  • [5] Intravascular ultrasound imaging before and after angioplasty for stenosis of arteriovenous fistulae in haemodialysis patients
    Higuchi, T
    Okuda, N
    Aoki, K
    Ishii, Y
    Matsumoto, H
    Ohnishi, Y
    Hagi, C
    Kikuchi, F
    Okada, K
    Kuno, T
    Honye, J
    Saito, S
    Nagura, Y
    Takahashi, S
    Kanmatsuse, K
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (01) : 151 - 155
  • [6] Accuracy of physical examination in the detection of arteriovenous fistula stenosis
    Asif, Arif
    Leon, Carlos
    Orozco-Vargas, Luis Carlos
    Krishnamurthy, Gururaj
    Choi, Kenneth L.
    Mercado, Carlos
    Merrill, Donna
    Thomas, Ian
    Salman, Loay
    Artikov, Shukhrat
    Bourgoignie, Jacques J.
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 2 (06): : 1191 - 1194
  • [7] Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis
    Tessitore, N
    Bedogna, V
    Gammaro, L
    Lipari, G
    Poli, A
    Baggio, E
    Firpo, M
    Morana, G
    Mansueto, G
    Maschio, G
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2003, 42 (02) : 331 - 341
  • [8] Accuracy of early postoperative clinical and ultrasound examination of arteriovenous fistulae to predict dialysis use
    Ferring, Martin
    Henderson, John
    Wilmink, Teun
    [J]. JOURNAL OF VASCULAR ACCESS, 2014, 15 (04): : 291 - 297
  • [9] Duplex ultrasound of external carotid artery branches for the detection of dural arteriovenous fistulae
    Arning, C
    Grzyska, U
    Lachenmayer, L
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (02): : 236 - 241
  • [10] Accuracy of Doppler ultrasound in diagnosing anatomic stenosis of hemodialysis arteriovenous access as compared with fistulography
    Gadallah, MF
    Paulson, WD
    Vickers, B
    Work, J
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 32 (02) : 273 - 277