Portable Filter-Based Microdevice for Detection and Characterization of Circulating Tumor Cells

被引:355
|
作者
Lin, Henry K. [1 ]
Zheng, Siyang [2 ]
Williams, Anthony J. [3 ]
Balic, Marija [4 ]
Groshen, Susan [5 ]
Scher, Howard I. [6 ]
Fleisher, Martin [7 ]
Stadler, Walter [8 ]
Datar, Ram H. [3 ]
Tai, Yu-Chong [9 ]
Cote, Richard J. [3 ]
机构
[1] Oak Ridge Natl Lab, Biosci Div, Oak Ridge, TN USA
[2] Penn State Univ, Dept Bioengn, University Pk, PA 16802 USA
[3] Univ Miami, Miller Sch Med, Dept Pathol, Miami, FL 33136 USA
[4] Med Univ Graz, Dept Oncol, Graz, Austria
[5] Univ So Calif, Keck Sch Med, Dept Prevent Med, Los Angeles, CA 90033 USA
[6] Mem Sloan Kettering Canc Ctr, Genitourinary Oncol Serv, New York, NY 10021 USA
[7] Mem Sloan Kettering Canc Ctr, Dept Clin Labs, New York, NY 10021 USA
[8] Univ Chicago, Pritzker Sch Med, Dept Med, Chicago, IL 60637 USA
[9] CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
基金
美国国家卫生研究院;
关键词
RESISTANT PROSTATE-CANCER; BREAST-CANCER; SEPARATION; SURVIVAL; DISEASE; SIZE;
D O I
10.1158/1078-0432.CCR-10-1105
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Sensitive detection and characterization of circulating tumor cells (CTC) could revolutionize the approach to patients with early-stage and metastatic cancer. The current methodologies have significant limitations, including limited capture efficiency and ability to characterize captured cells. Here, we report the development of a novel parylene membrane filter-based portable microdevice for size-based isolation with high recovery rate and direct on-chip characterization of captured CTC from human peripheral blood. Experimental Design: We evaluated the sensitivity and efficiency of CTC capture in a model system using blood samples from healthy donors spiked with tumor cell lines. Fifty-nine model system samples were tested to determine the recovery rate of the microdevice. Moreover, 10 model system samples and 57 blood samples from cancer patients were subjected to both membrane microfilter device and Cell Search platform enumeration for direct comparison. Results: Using the model system, the microdevice achieved >90% recovery with probability of 95% recovering at least one cell when five are seeded in 7.5 mL of blood. CTCs were identified in 51 of 57 patients using the microdevice, compared with only 26 patients with the Cell Search method. When CTCs were detected by both methods, greater numbers were recovered by the microfilter device in all but five patients. Conclusions: This filter-based microdevice is both a capture and analysis platform, capable of multiplexed imaging and genetic analysis. The microdevice presented here has the potential to enable routine CTC analysis in the clinical setting for the effective management of cancer patients. Clin Cancer Res; 16(20); 5011-8. (C) 2010 AACR.
引用
收藏
页码:5011 / 5018
页数:8
相关论文
共 50 条
  • [1] Filter-based isolation, enrichment, and characterization of circulating tumor cells
    Khetani, Sultan
    Mohammadi, Mehdi
    Nezhad, Amir Sanati
    BIOTECHNOLOGY AND BIOENGINEERING, 2018, 115 (10) : 2504 - 2529
  • [2] Microdevice for Trapping Circulating Tumor Cells for Cancer Diagnostics
    Tan, S. J.
    Yobas, L.
    Lee, G. Y. H.
    Ong, C. N.
    Lim, C. T.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 774 - +
  • [3] Molecular detection and characterization of circulating tumor cells
    Haber, Daniel A.
    MOLECULAR CANCER THERAPEUTICS, 2018, 17 (01)
  • [4] Optimal filter-based detection of microcalcifications
    Gulsrud, TO
    Husoy, JH
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (11) : 1272 - 1281
  • [5] Immunobead-based detection and characterization of circulating tumor cells in melanoma patients
    Fodstad, O
    Faye, R
    Hoifodt, HK
    Skovlund, E
    Aamdal, S
    MINIMAL RESIDUAL DISEASE IN MELANOMA: BIOLOGY, DETECTION AND CLINICAL RELEVANCE, 2001, 158 : 40 - 50
  • [6] Immunobead-based detection and characterization of circulating tumor cells in melanoma patients
    Fodstad, O
    Faye, R
    Hoifodt, H
    Skovlund, E
    Aamdal, S
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1999, 113 (03) : 512 - 512
  • [7] GABOR FILTER-BASED EDGE-DETECTION
    MEHROTRA, R
    NAMUDURI, KR
    RANGANATHAN, N
    PATTERN RECOGNITION, 1992, 25 (12) : 1479 - 1494
  • [8] High-Performance Size-Based Microdevice for the Detection Of Circulating Tumor Cells from Peripheral Blood in Rectal Cancer Patients
    Sun, Wenjie
    Jia, Chunping
    Huang, Ting
    Sheng, Weiqi
    Li, Guichao
    Zhang, Honglian
    Jing, Fengxiang
    Jin, Qinghui
    Zhao, Jianlong
    Li, Gang
    Zhang, Zhen
    PLOS ONE, 2013, 8 (09):
  • [9] ENHANCED CHEMILUMINESCENCE IN FILTER-BASED DNA DETECTION
    SIMMONDS, AC
    CUNNINGHAM, M
    DURRANT, I
    FOWLER, SJ
    EVANS, MR
    CLINICAL CHEMISTRY, 1991, 37 (09) : 1527 - 1528
  • [10] Gabor filter-based edge detection: A note
    Liu, Song-lin
    Niu, Zhao-dong
    Sun, Gang
    Chen, Zeng-ping
    OPTIK, 2014, 125 (15): : 4120 - 4123