Thermal performance investigation of borehole heat exchanger with different U-tube diameter and borehole parameters

被引:9
|
作者
Li, Yang [1 ]
An, Qingsong [1 ]
Liu, Liangxu [1 ]
Zhao, Jun [1 ]
机构
[1] Tianjin Univ, Minist Educ China, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300072, Peoples R China
关键词
Borehole heat exchanger; U-tube diameter; Ground-coupled heat pump; TRNSYS; Heat exchange rate; SYSTEMS;
D O I
10.1016/j.egypro.2014.12.278
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
At present the U-tube borehole heat exchanger (BHE) used for ground-coupled heat pump (GCHP) system mostly applies 32 mm as outer diameter. In order to compare the heat transfer capacity of this diameter with other nearby standard diameters, the thermal performance of U-tube BHE with four kinds of standard outer diameter were simulated by TRNSYS based on a GCHP system case in Tianjin, heat exchange rate and total BHEs number were calculated under different borehole depth and borehole diameter. The simulation result indicated that under the same borehole depth and borehole diameter, BHEs number was the fewest when the U-tube outer diameter was 25 mm, however the cases used U-tube with 32 mm outer diameter needed the most BHEs to meet the load demand. Furthermore, another single borehole simulation was conducted to show that thicker U-tube wall is the reason that U-tube BHE with 32 mm outer diameter had relatively worse thermal performance due to its larger thermal resistance, which offset the positive effect of bigger heat exchange area. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:2690 / 2694
页数:5
相关论文
共 50 条
  • [1] Borehole thermal resistance of U-tube borehole heat exchanger
    Abuel-Naga, H. M.
    Al-Chalabi, R. R.
    [J]. GEOTECHNIQUE LETTERS, 2016, 6 (04) : 250 - 255
  • [2] Thermal performance and economic evaluation of double U-tube borehole heat exchanger with three different borehole diameters
    Luo, Jin
    Rohn, Joachim
    Bayer, Manfred
    Priess, Anna
    [J]. ENERGY AND BUILDINGS, 2013, 67 : 217 - 224
  • [3] Vertical temperature profiles and borehole resistance in a U-tube borehole heat exchanger
    Beier, Richard A.
    Acuna, Jose
    Mogensen, Palne
    Palm, Bjorn
    [J]. GEOTHERMICS, 2012, 44 : 23 - 32
  • [4] Transient heat transfer in a U-tube borehole heat exchanger
    Beier, Richard A.
    [J]. APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 256 - 266
  • [5] EFFECTIVE BOREHOLE THERMAL RESISTANCE OF A SINGLE U-TUBE GROUND HEAT EXCHANGER
    Liao, Quan
    Zhou, Chao
    Cui, Wenzhi
    Jen, Tien-Chien
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2012, 62 (03) : 197 - 210
  • [6] U-Tube Diameter Dependence of Heat Output for Borehole Heat Exchangers
    Dai, Chuanshan
    Wang, Shuai
    Qin, Weixing
    [J]. PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 2613 - +
  • [7] Thermo-Hydraulic Performance of U-Tube Borehole Heat Exchanger with Different Cross-Sections
    Zhou, Aizhao
    Huang, Xianwen
    Wang, Wei
    Jiang, Pengming
    Li, Xinwei
    [J]. SUSTAINABILITY, 2021, 13 (06)
  • [8] Heat transfer simulation, analysis and performance study of single U-tube borehole heat exchanger
    Kerme, Esa Dube
    Fung, Alan S.
    [J]. RENEWABLE ENERGY, 2020, 145 : 1430 - 1448
  • [9] Transient heat transfer performance of a vertical double U-tube borehole heat exchanger under different operation conditions
    Zhu, Li
    Chen, Sarula
    Yang, Yang
    Sun, Yong
    [J]. RENEWABLE ENERGY, 2019, 131 : 494 - 505
  • [10] Analysis of the transient performance of coaxial and u-tube borehole heat exchangers
    Harris, B. E.
    Lightstone, M. F.
    Reitsma, S.
    Cotton, J. S.
    [J]. GEOTHERMICS, 2022, 101