MULTI-FOCUS BEAMFORMING FOR THERMAL STRAIN IMAGING USING A SINGLE ULTRASOUND LINEAR ARRAY TRANSDUCER

被引:9
|
作者
Nguyen, Man M. [1 ,2 ]
Ding, Xuan [1 ,2 ,3 ,4 ,5 ]
Leers, Steven A. [6 ,7 ]
Kim, Kang [1 ,2 ,3 ,6 ,7 ,8 ]
机构
[1] Univ Pittsburgh, Ctr Ultrasound Mol Imaging & Therapeut, Sch Med, Dept Med, Pittsburgh, PA USA
[2] Univ Pittsburgh, Med Ctr, Pittsburgh, PA USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[4] Univ Pittsburgh, Med Scientist Training Program, Pittsburgh, PA USA
[5] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
[6] Univ Pittsburgh, Inst Heart & Vasc, Sch Med, Pittsburgh, PA USA
[7] UPMC, Pittsburgh, PA USA
[8] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2017年 / 43卷 / 06期
基金
美国国家卫生研究院;
关键词
Beamforming; Apodization; Thermal strain imaging; Multiple foci; Linear array; Carotid plaque characterization; VULNERABLE ATHEROSCLEROTIC PLAQUE; IN-VIVO CHARACTERIZATION; DISPLACEMENT ESTIMATION; TISSUE TEMPERATURE; CROSS-CORRELATION; DUAL APODIZATION; CAROTID PLAQUES; SYSTEM; RECONSTRUCTION; IDENTIFICATION;
D O I
10.1016/j.ultrasmedbio.2017.01.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound-induced thermal strain imaging (TSI) has been used successfully to identify lipid- and water-based tissues in atherosclerotic plaques in some research settings. However, TSI faces several challenges to be realized in clinics. These challenges include motion artifacts and displacement tracking accuracy, as well as limited heating capability, which contributes to low thermal strain signal-to-noise ratio, and a limited field of view. Our goal was to address the challenge in heating tissue in TSI. Current TSI systems use separate heating and imaging transducers, which require physical alignment of the heating and imaging beams and result in a bulky setup that limits in vivo operation. We evaluated a new design for heating beams that can be implemented on a linear array imaging transducer and can provide improved heating area and efficiency as compared with previous implementations. The heating beams designed were implemented with a clinical linear array imaging transducer connected to a research ultrasound platform. In vitro experiments using tissue-mimicking phantoms with no blood flow revealed that the new design resulted in an effective heating area of approximately 0.85 cm(2) and a 0.3 degrees C temperature rise in 2 s of heating, which compared well with in silico finite-element simulations. With the new heating beams, TSI was found to be able to detect a lipid- mimicking rubber inclusion with a diameter of 1 cm from the water-based gelatin background, with a strain contrast of 2.3 (+0.14% strain in the rubber inclusion and -0.06% strain in the gelatin background). Lastly, lipid- based tissue in a 1-cm-diameter human carotid endarterectomy (CEA) sample was identified in good agreement with histology. (C) 2017 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1263 / 1274
页数:12
相关论文
共 50 条
  • [1] Adaptive Beamforming for Thermal Strain Imaging Using a Single Ultrasound Linear Array
    Nguyen, Man M.
    Ding, Xuan
    Yu, Francois
    Kim, Kang
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1686 - 1689
  • [2] Inducing and Imaging thermal strain using a single ultrasound linear array
    Huang, Sheng-Wen
    Kim, Kang
    Witte, Russell S.
    Olafsson, Ragnar
    O'Donnell, Matthew
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (09) : 1718 - 1720
  • [3] Beamforming for photoacoustic imaging using linear array transducer
    Park, Suhyun
    Aglyamov, Salavat R.
    Emelianov, Stanislav Y.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 856 - 859
  • [4] Adaptive beamforming for photoacoustic imaging using linear array transducer
    Park, Suhyun
    Karpiouk, Andrei B.
    Aglyamov, Salavat R.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1088 - 1091
  • [5] MULTI-FOCUS ULTRASOUND IMAGING USING GENERATIVE ADVERSARIAL NETWORKS
    Goudarzi, Sobhan
    Asif, Amir
    Rivaz, Hassan
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 1118 - 1121
  • [6] MULTIFOCUS THERMAL STRAIN IMAGING USING A CURVED LINEAR ARRAY TRANSDUCER FOR IDENTIFICATION OF LIPIDS IN DEEP TISSUE
    Khalid, Waqas B.
    Chen, Xucai
    Kim, Kang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (07): : 1711 - 1724
  • [7] Multi-focus imaging using local focus estimation and mosaicking
    Fedorov, Dmitry
    Sumengen, Baris
    Manjunath, B. S.
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 2093 - +
  • [8] Ultrasound-Guided Gas Embolization Using a Single Linear Array Transducer
    Harmon, Jennifer N.
    Kabinejadian, Foad
    Bull, Joseph L.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1193 - 1196
  • [9] Theoretical evaluation of moderately focused spherical transducers and multi-focus acoustic lens/transducer systems for ultrasound thermal therapy
    Wu, X
    Sherar, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09): : 1603 - 1621
  • [10] Single element and linear array transducer design for Ultrasound Biomicroscopy
    Lukacs, M
    Sayer, M
    Foster, S
    ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1998, 1998, 3341 : 272 - 282