CAN 120-MLC IMRT PLANS BE TREATED ON AN 80-MLC LINEAR ACCELERATOR?

被引:0
|
作者
Calvo, O. [1 ]
Xudong, W. [1 ]
Esquivel, C. [1 ]
Stathakis, S. [1 ]
Papanikolaou, N. [1 ]
机构
[1] UT HSC San Antonio, CTRC, Dept Radiat Oncol, San Antonio, TX USA
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1587
引用
收藏
页码:S545 / S545
页数:1
相关论文
共 50 条
  • [1] Implications of 120-MLC Plans Treated on an 80-MLC Linear Accelerator
    Esquivel, C.
    Wang, X.
    Calvo, O.
    Stathakis, S.
    Corona, I.
    Mihailidis, D.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [2] Dosimetric Evaluation of a 120-MLC Plan Delivered On a 80-MLC Linear Accelerator
    Corona, I.
    Esquivel, C.
    Gutierrez, A.
    Stathakis, S.
    Shi, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2009, 36 (06) : 2629 - +
  • [3] Comparison of Methods to Convert Treatment Plans On Millennium MLC to HD120 MLC
    Shukla, G.
    Meekins, E.
    MEDICAL PHYSICS, 2019, 46 (06) : E329 - E330
  • [4] Adapting VMAT plans optimized for an HD120 MLC for delivery with a Millennium MLC
    French, Samuel B.
    Bhagroo, Stephen
    Nazareth, Daryl P.
    Podgorsak, Matthew B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 143 - 151
  • [5] IMRT plans for head and neck patients can be simplified and efficiently delivered with static MLC
    Xia, P
    Ludlum, E
    Gliessmann, S
    Bucci, MK
    Quivey, JM
    Verhey, LJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S517 - S517
  • [6] MLC and IMRT independent audits of linear accelerators
    Pavlikova, I.
    Horakova, I.
    Koncek, O.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S249 - S249
  • [7] MLC complexity metrics in clinical online adapted IMRT plans delivered with a double-stacked MLC
    Sibolt, P.
    Momsen, N. C.
    Astrom, L. M.
    Bjelkengren, U.
    Sjostrom, D.
    Behrens, C. P.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S828 - S829
  • [8] Influence of MLC leaf width on biologically adapted IMRT plans
    Rodal, Jan
    Sovik, Aste
    Malinen, Eirik
    ACTA ONCOLOGICA, 2010, 49 (07) : 1116 - 1123
  • [9] Comparison of IMRT commissioning for Varian 2300CD/120 MLC and 6EX/80 MLC on ADAC/pinnacle and corvus planning systems
    Teslow, T
    Alahakone, D
    Frensemeier, J
    He, S
    Detorie, N
    MEDICAL PHYSICS, 2004, 31 (06) : 1871 - 1871
  • [10] Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system
    Li, Ji
    Wiersma, Rodney D.
    Stepaniak, Christopher J.
    Farrey, Karl J.
    Al-Hallaq, Hania A.
    MEDICAL PHYSICS, 2012, 39 (05) : 2456 - 2462