A beam hardening correction for X-ray microtomography

被引:15
|
作者
de Paiva, RF [1 ]
Lynch, J [1 ]
Rosenberg, E [1 ]
Bisiaux, M [1 ]
机构
[1] Inst Francais Petr, F-92500 Rueil Malmaison, France
关键词
X-rays; microtomography; quantification;
D O I
10.1016/S0963-8695(97)00032-7
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We propose a correction of the transmitted intensities in X-ray microscopy allowing improved quantification for polychromatic sources, particularly in tomographic reconstruction. The correction is based on the application of Beer's law for each energy present in the source spectrum. Knowledge of the source spectrum and the average specimen composition are used. The correction is demonstrated on a chemically homogeneous specimen (a glass capillary filled with glass beads) and on a polyphasic oil reservoir rock sample. In the former, detection of 20 mu m defects is demonstrated. In the latter, different minerals, quartz, feldspath and kaolinite, can be discriminated and their distributions mapped. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 50 条
  • [1] The effect of beam hardening on resolution in X-ray microtomography
    Van de Casteele, E
    Van Dyck, D
    Sijbers, J
    Raman, E
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2089 - 2096
  • [2] A model-based correction method for beam hardening artefacts in X-ray microtomography
    Van de Casteele, E.
    Van Dyck, D.
    Sijbers, J.
    Raman, E.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (01) : 43 - 57
  • [3] Reduction of beam hardening artifacts in X-ray microtomography data
    Crostack, HA
    Nellesen, J
    NONDESTRUCTIVE CHARACTERIZATION OF MATERIALS XI, 2003, : 261 - 268
  • [4] Correction of beam hardening in X-ray radiograms
    Baur, Manuel
    Uhlmann, Norman
    Poeschel, Thorsten
    Schroeter, Matthias
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (02):
  • [5] Multi-species Beam Hardening Calibration Device for X-ray Microtomography
    Evershed, Anthony N. Z.
    Mills, David
    Davis, Graham
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [6] TOWARDS BEAM HARDENING CORRECTION FOR POLYCHROMATIC X-RAY CT
    Park, Hyoung Suk
    Gao, Hao
    Lee, Sung Min
    Seo, Jin Keun
    JOURNAL OF COMPUTATIONAL MATHEMATICS, 2016, 34 (06) : 671 - 682
  • [7] Beam hardening correction in polychromatic x-ray grating interferometry
    Yan, Aimin
    Wu, Xizeng
    Liu, Hong
    OPTICS EXPRESS, 2017, 25 (20): : 24690 - 24704
  • [8] Beam hardening fitting correction method for X-ray TICT
    Department of Phy. and Electr., Hunan University of Arts and Science, Changde 415000, China
    不详
    不详
    不详
    Guangdian Gongcheng, 2006, 11 (137-141):
  • [9] X-ray beam hardening correction by minimising reprojection distance
    Kingston, Andrew M.
    Myers, Glenn R.
    Varslot, Trond K.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [10] X-ray micro radiography using beam hardening correction
    Vavrik, Daniel
    Holy, Tomas
    Jakubek, Jan
    Pospisil, Stanislav
    Vykydal, Zdenek
    Dammer, Jiri
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2989 - 2992