The importance of AIF ROI selection in DCE-MRI renography: Reproducibility and variability of renal perfusion and filtration

被引:44
|
作者
Cutajar, M. [1 ,2 ]
Mendichovszky, I. A. [3 ]
Tofts, P. S. [2 ,4 ]
Gordon, I. [1 ]
机构
[1] UCL Inst Child Hlth, Radiol & Phys Unit, London WC1N 1EH, England
[2] Univ Sussex, Brighton & Sussex Med Sch, Brighton BN1 9PX, E Sussex, England
[3] Univ Manchester, Manchester M13 9PT, Lancs, England
[4] UCL Inst Neurol, London WC1N 3BG, England
关键词
Renal dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI); Aortic input function analysis; Reproducibility study; Gadolinium; Three-compartment tracer kinetics model; Perfusion; GFR; CONTRAST-ENHANCED MRI; PATLAK PLOT TECHNIQUE; GLOMERULAR-FILTRATION; COMPARTMENT MODEL; KIDNEY; DTPA; IMAGES;
D O I
10.1016/j.ejrad.2009.05.041
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to investigate (a) the effect the choice of the region of interest (ROI) defining the aortic input function (AIF) has on the estimation of renal perfusion and filtration in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) renography, and (b) the reproducibility of these parameters. Using renal DCE-MRI and a three-compartment model analysis, this work evaluated the effect two different AIFs, derived from variable sized ROIs in the aorta, has on calculating DCE-MRI renal perfusion and filtration values in a group of healthy adult volunteers who underwent two consecutive renal DCE-MRI studies. Methods: Fifteen healthy volunteers underwent two DCE-MRI studies under similar physiological conditions. Oblique-coronal DCE-MRI data volumes were acquired on a 1.5 T Siemens Avanto scanner with a 3D-FLASH pulse-sequence (TE/TR = 0.53/1.63 ms, flip angle = 17 degrees, acquisition matrix = 128 x 104 voxels, strong fat saturation, PAT factor = 2 (GRAPPA) and 400 mm x 325 mm FOV). Each dynamic dataset consisted of 18 slices of 7.5 mm thickness (no gap) and an in-plane resolution of 3.1 mm x 3.1 mm, acquired every 2.5 s for not less than 5 minutes. During the MR scan a dose of 0.05 mmol (0.1 mL) kg(-1) body weight of dimeglumine gadopentetate (Magnevist) was injected intravenously (2 mL s(-1) injection rate), followed by a 15 mL saline flush at the same rate, using a MR-compatible automated injector (Spectris). Two AIFs were defined for each volunteer by drawing two ROIs in the aorta for each study. Renal perfusion and glomerular filtration rate (GFR) values were then calculated for each of the AIFs using a modified Tofts Renal Model (TRM). Both renal perfusion and GFR were expressed in mL min(-1) 100 mL(-1) of tissue. Results and conclusion: Inter-individual reproducibility tests for renal perfusion and glomerular filtration rate showed that the size of AIF ROIs significantly affects calculated values of perfusion and GFR (p-values <0.02). No significant differences were observed when comparing perfusion and GFR values in the same volunteer between scans performed on different days (p-values >0.22). From our study we conclude that while DCE-MRI derived indices of renal function are reproducible in the same individual when imaged on different days, the size of the aortic ROI and hence the AIF has a significant influence on calculated renal perfusion and GFR values. Currently there is no accepted standard for drawing the aortic ROI and no standardized approach for the AIF definition in renal DCE-MRI studies. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E155 / E161
页数:7
相关论文
共 12 条
  • [1] Reproducibility and Comparison of DCE-MRI and DCE-CT Perfusion Parameters in a Rat Tumor Model
    Ng, Chaan S.
    Waterton, John C.
    Kundra, Vikas
    Brammer, David
    Ravoori, Murali
    Han, Lin
    Wei, Wei
    Klumpp, Sherry
    Johnson, Valen E.
    Jackson, Edward F.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2012, 11 (03) : 279 - 288
  • [2] DCE-MRI of the Liver: Effect of Linear and Nonlinear Conversions on Hepatic Perfusion Quantification and Reproducibility
    Aronhime, Shimon
    Calcagno, Claudia
    Jajamovich, Guido H.
    Dyvorne, Hadrien Arezki
    Robson, Philip
    Dieterich, Douglas
    Fiel, M. Isabel
    Martel-Laferriere, Valerie
    Chatterji, Manjil
    Rusinek, Henry
    Taouli, Bachir
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 90 - 98
  • [3] Renal DCE-MRI Model Selection Using Bayesian Probability Theory
    Beeman, Scott C.
    Osei-Owusu, Patrick
    Duan, Chong
    Engelbach, John
    Bretthorst, G. Larry
    Ackerman, Joseph J. H.
    Blumer, Kendall J.
    Garbow, Joel R.
    [J]. TOMOGRAPHY, 2015, 1 (01) : 61 - 68
  • [4] Renal perfusion in acute kidney injury with DCE-MRI: Deconvolution analysis versus two-compartment filtration model
    Zoellner, Frank G.
    Zimmer, Fabian
    Klotz, Sarah
    Hoeger, Simone
    Schad, Lothar R.
    [J]. MAGNETIC RESONANCE IMAGING, 2014, 32 (06) : 781 - 785
  • [5] The reproducibility of perfusion parameters obtained from dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) in liver and lung tumors, and implications for sample size in clinical trials using DCE-MRI
    Ng, C. S.
    Jackson, E. F.
    Ashton, E.
    Raunig, D. L.
    Kelcz, F.
    Kurzrock, R.
    Charnsangavej, C.
    Evelhoch, J.
    McShane, J. M.
    [J]. EJC SUPPLEMENTS, 2006, 4 (12): : 43 - 44
  • [6] Deterministic Arterial Input Function selection in DCE-MRI for automation of quantitative perfusion calculation of colorectal cancer
    Toennes, Christian
    Janssen, Sonja
    Golla, Alena-Kathrin
    Uhrig, Tanja
    Chung, Khanlian
    Schad, Lothar R.
    Zoellner, Frank Gerrit
    [J]. MAGNETIC RESONANCE IMAGING, 2021, 75 : 116 - 123
  • [7] Use of 3D DCE-MRI for the Estimation of Renal Perfusion and Glomerular Filtration Rate: An Intrasubject Comparison of FLASH and KWIC With a Comprehensive Framework for Evaluation
    Eikefjord, Eli
    Andersen, Erling
    Hodneland, Erlend
    Zoellner, Frank
    Lundervold, Arvid
    Svarstad, Einar
    Rorvik, Jarle
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : W273 - W281
  • [8] DYNAMIC CONTRAST ENHANCED MRI (DCE-MRI) FOR EVALUATION OF THE EFFECTS OF RENO-PROTECTIVE DRUGS ON RENAL PERFUSION AFTER SWL
    El-Nahas, Ahmed
    El-Ghar, Mohamed Abo
    Taha, Diaa-Eldin
    Elsaadany, Mohamed
    Elshal, Ahmed
    Sheir, Khaled
    [J]. JOURNAL OF UROLOGY, 2016, 195 (04): : E726 - E726
  • [9] Reproducibility of the aortic input function (AIF) derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the kidneys in a volunteer study
    Mendichovszky, I. A.
    Cutajar, M.
    Gordon, I.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) : 576 - 581
  • [10] Quantitative Renal Perfusion Measurements in a Rat Model of Acute Kidney Injury at 3T: Testing Inter- and Intramethodical Significance of ASL and DCE-MRI
    Zimmer, Fabian
    Zoellner, Frank G.
    Hoeger, Simone
    Klotz, Sarah
    Tsagogiorgas, Charalambos
    Kraemer, Bernhard K.
    Schad, Lothar R.
    [J]. PLOS ONE, 2013, 8 (01):