Improved Operating Scheme Using an IEC61850-based Distance Relay for Transformer Backup Protection

被引:0
|
作者
Kim, Hyung-Kyu [1 ]
Kang, Sang-Hee [1 ]
Nam, Soon-Ryul [1 ]
Oh, Sea-Seung [1 ]
机构
[1] Myongji Univ, Next Generat Power Technol Ctr NPTC, Seoul, South Korea
关键词
IEC61850; Distance relay; Transformer backup protection; GOOSE message; Quadrilateral relay;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Problems occur when zones overlap in the conventional step distance protection scheme. If the same zones from different relays overlap, discriminating between the real fault location and the virtual one is difficult, and malfunction can occur. In this case, the zone length or time delay is usually modified to separate the overlapped zones. However, these changes affect the coordination of the power protection system. A clear example of this involves transformer backup protection. Generally, when Zone 2 of a transformer backup protection relay overlaps Zone 2 of an adjacent line backup protection, the method of modifying this zone may not be obvious. To overcome this problem, this paper describes an improved operating scheme using an IEC61850-based distance relay for transformer backup protection.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 50 条
  • [1] The design and operation of IEC61850-based transformer measuring device
    Kopanski, Pawel
    Kowalik, Ryszard
    Rasolomampionona, Desire
    [J]. 2014 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON 2014), 2014, : 786 - 792
  • [2] IEC61850-based Protection System for MV/LV Substations
    Suarez, Fernando A. Fuentes
    Ragaini, Enrico
    [J]. 2017 IEEE WORKSHOP ON POWER ELECTRONICS AND POWER QUALITY APPLICATIONS (PEPQA), 2017, : 48 - 52
  • [3] Modeling and Co-simulation of IEC61850-Based Microgrid Protection
    Wong, T. Y.
    Shum, C.
    Lau, W. H.
    Chung, S. H.
    Tsang, K. F.
    Tse, C. F.
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON SMART GRID COMMUNICATIONS (SMARTGRIDCOMM), 2016,
  • [4] IEC 61850 Communication Based Distance Protection
    Wannous, Kinan
    Toman, Petr
    [J]. PROCCEDINGS OF THE 2014 15TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2014,
  • [5] An Investigation into the Design of an IEC 61850 Based Protection Relay
    Sun, Xin
    Redfern, Miles A.
    [J]. UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 951 - 955
  • [6] Backup subscription scheme for differential protection using IEC61850-9-2 sampled values
    Department of energy systems, Norwegian University of Science and Technology, Trondheim, Norway
    不详
    不详
    不详
    MI
    49931, United States
    [J]. Energy. Inform., 1
  • [7] Real-Time Modeling and Testing of Distance Protection Relay Based on IEC 61850 Protocol
    Delavari, Atieh
    Brunelle, Patrice
    Mugombozi, Chuma Francis
    [J]. CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2020, 43 (03): : 157 - 162
  • [8] Testing IEC-61850 Sampled Values-Based Transformer Differential Protection Scheme
    Sharma, Mohit
    Nguyen, Lam
    Kuber, Sughosh
    Baradi, Dinesh
    [J]. 2021 74TH CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2021,
  • [9] Novel protection scheme based on IEC61850
    Garcia-Gracia, M.
    Borroy, S.
    Gimenez de Urtasun, L.
    Comech, M. P.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (12) : 2178 - 2187
  • [10] IEC61850-Based Analysis of Coal Mine Ground Transformer Substation Integrated Automation Communication System
    Gao Yongxin
    [J]. HYDRAULIC EQUIPMENT AND SUPPORT SYSTEMS FOR MINING, 2013, 619 : 199 - 202