Surface electromyography activity of trunk muscles during conventional and non-conventional wheelchair propulsion

被引:0
|
作者
Khalil, Hassan [1 ]
Diab, Ahmad [2 ]
Atallah, Tarek [1 ]
Daher, Alaa [2 ]
Sarraj, Ahmad Rifai [3 ]
机构
[1] Lebanese Univ, Div Masters, Fac Publ Hlth, Beirut, Lebanon
[2] Lebanese Univ, AZM Ctr Res Biotechnol & Its Applicat, Doctoral Sch Sci & Technol, Tripoli, Lebanon
[3] Lebanese Univ, Lab Motor Syst Handicap & Rehabil MOHAR, Beirut, Lebanon
关键词
Electromyography; Trunk muscle recruitment; Hand-rim wheelchair; Lever propelled wheelchair propulsion; Spinal cord injury; SPINAL-CORD-INJURY; SHOULDER MUSCLES; SEAT POSITION; BIOMECHANICS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this experimental comparative study between a prototype lever-propelled wheelchair and conventional hand rim wheelchair, trunk muscles activity in able-bodied subjects was examined using surface electromyography (SEMG). Fifteen healthy males and non-wheelchair users were recruited in Tripoli, Lebanon. Participants successfully performed two propulsion trials on both types of wheelchair: conventional (hand rim; CHr) and non-conventional (lever-propelled prototype; NCLP) at a preselected speed of 0.9 m/s. Variables measured included muscle activity, frequencies, fatigability and the intensity of muscle contractions on two types of propulsion. Results showed that both abdominal and back muscle groups revealed significantly lower activation during NC-LP compared to the C-Hr propulsion. Results showed also muscle activation profile of the trunk musculature at two type of wheelchair propulsion. Our results suggested a necessity of a future study design methodology including wheelchair users with spinal cord injury.
引用
收藏
页码:226 / 229
页数:4
相关论文
共 50 条
  • [1] Surface electromyography activity of trunk muscles during wheelchair propulsion
    Yang, Yu-Sheng
    Koontz, Alicia M.
    Triolo, Ronald J.
    Mercer, Jennifer L.
    Boninger, Michael L.
    CLINICAL BIOMECHANICS, 2006, 21 (10) : 1032 - 1041
  • [2] Surface electromyography activity of upper limb muscle during wheelchair propulsion: Influence of wheelchair configuration
    Louis, N.
    Gorce, P.
    CLINICAL BIOMECHANICS, 2010, 25 (09) : 879 - 885
  • [3] Non-conventional solutions for non-conventional dilemmas?
    Shapir, YS
    JOURNAL OF STRATEGIC STUDIES, 2001, 24 (02) : 147 - +
  • [4] GENETIC MANIPULATION OF NON-CONVENTIONAL YEASTS BY CONVENTIONAL AND NON-CONVENTIONAL METHODS
    SPENCER, JFT
    SPENCER, DM
    REYNOLDS, N
    JOURNAL OF BASIC MICROBIOLOGY, 1988, 28 (05) : 321 - 333
  • [5] Non-Conventional Treatments for Conventional Chondrosarcoma
    Monga, Varun
    Mani, Hariharasudan
    Hirbe, Angela
    Milhem, Mohammed
    CANCERS, 2020, 12 (07) : 1 - 12
  • [6] Conventional and non-conventional applications of β-galactosidases
    Vera, Carlos
    Guerrero, Cecilia
    Aburto, Carla
    Cordova, Andres
    Illanes, Andres
    BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS, 2020, 1868 (01):
  • [7] Electromyography activity of selected trunk muscles during cardiopulmonary resuscitation
    Tsou, Jui-Yi
    Su, Fong-Chin
    Tsao, Pai-Chin
    Hong, Ming-Yuan
    Cheng, Su-Chun
    Chang, Hsun-Wen
    Yang, Jin-Shiou
    Chi, Chih-Hsien
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (03): : 216 - 220
  • [8] Non-conventional yeasts
    Spencer, JFT
    de Spencer, ALR
    Laluce, C
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2002, 58 (02) : 147 - 156
  • [9] NON-CONVENTIONAL COATINGS
    GATE, PAJ
    JOURNAL OF THE OIL & COLOUR CHEMISTS ASSOCIATION, 1977, 60 (01): : 34 - 35
  • [10] Non-conventional energy
    Kokare, S