Clinical feasibility of an abdominal thin-slice breath-hold single-shot fast spin echo sequence processed using a deep learning-based noise-reduction approach

被引:15
|
作者
Tajima, Taku [1 ,2 ]
Akai, Hiroyuki [3 ]
Yasaka, Koichiro [4 ]
Kunimatsu, Akira [1 ]
Akahane, Masaaki [2 ]
Yoshioka, Naoki [2 ]
Abe, Osamu [4 ]
Ohtomo, Kuni [5 ]
Kiryu, Shigeru [2 ]
机构
[1] Int Univ Hlth & Welf, Mita Hosp, Dept Radiol, 1-4-3 Mita,Minato Ku, Tokyo 1088329, Japan
[2] Int Univ Hlth, Welf Narita Hosp, Dept Radiol, 852 Hatakeda Narita, Chiba 2860124, Japan
[3] Univ Tokyo, Inst Med Sci, Dept Radiol, 4-6-1 Shirokanedai,Minato Ku, Tokyo 1088639, Japan
[4] Univ Tokyo, Grad Sch Med, Dept Radiol, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1130033, Japan
[5] Int Univ Hlth & Welf, 2600-1 kitakanamaru, Otawara, Tochigi 3248501, Japan
关键词
Magnetic resonance imaging; Deep learning; Denoise; Acceleration; Pancreas; Single-shot fast spin echo; MRI; COMPLICATIONS; PANCREATITIS; ABDOMEN;
D O I
10.1016/j.mri.2022.04.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: T2-weighted imaging (T2WI) is a key sequence of MRI studies of the pancreas. The single-shot fast spin echo (single-shot FSE) sequence is an accelerated form of T2WI. We hypothesized that denoising approach with deep learning-based reconstruction (dDLR) could facilitate accelerated breath-hold thin-slice single-shot FSE MRI, and reveal the pancreatic anatomy in detail. Purpose: To assess the image quality of thin-slice (3 mm) respiratory-triggered FSE T2WI (Resp-FSE) and breath-hold fast advanced spin echo with and without dDLR (BH-dDLR-FASE and BH-FASE, respectively) at 1.5 T. Materials and methods: MR images of 42 prospectively enrolled patients with suspected pancreaticobiliary disease were obtained at 1.5 T. We qualitatively and quantitatively evaluated image quality of BH-dDLR-FASE related to BH-FASE and Resp-FSE. Results: The scan time of BH-FASE was significantly shorter than that of Resp-FSE (30 +/- 4 s and 122 +/- 25 s, p < 0.001). Qualitatively, dDLR significantly improved BH-FASE image quality, and the image quality of BH-dDLR-FASE was significantly better than that of Resp-FSE; as quantitative parameters, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of BH-dDLR-FASE were also significantly better than those of Resp-FSE. The BH-dDLR-FASE sequence covered the entire pancreas and liver and provided overall image quality rated close to excellent. Conclusions: The dDLR technique enables accelerated thin-slice single-shot FSE, and BH-dDLR-FASE seems to be feasible.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 9 条
  • [1] Impact of Deep-Learning Based Reconstruction on Single-Breath-Hold, Single-Shot Fast Spin-Echo in MR Enterography for Crohn's Disease
    Park, Eun Joo
    Lee, Yedaun
    Lee, Joonsung
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2023, 84 (06): : 1309 - 1323
  • [2] Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: Comparison with high resolution turbo spin echo sequence
    Nakayama, Y
    Yamashita, Y
    Matsuno, Y
    Tang, Y
    Namimoto, T
    Kadota, M
    Mitsuzaki, K
    Abe, Y
    Katahira, K
    Arakawa, A
    Takahashi, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 55 - 60
  • [3] Impact of deep learning-based reconstruction and anti-peristaltic agent on the image quality and diagnostic performance of magnetic resonance enterography comparing single breath-hold single-shot fast spin echo with and without anti-peristaltic agent
    Park, Eun Joo
    Lee, Yedaun
    Lee, Ho-Joon
    Son, Jung Hee
    Yi, Jisook
    Hahn, Seok
    Lee, Joonsung
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 722 - 735
  • [4] Reproducibility of left ventricular mass measurement using a half-fourier black-blood single-shot fast spin-echo sequence within a single breath hold: Comparison with a conventional multiple breath-hold gradient echo technique segmented in patients
    Vignaux, O
    Duboc, D
    Coste, J
    Argaud, C
    Carlier, P
    Le Roux, P
    Weber, S
    Legmann, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (06) : 654 - 660
  • [5] Breath-hold 3D magnetic resonance cholangiopancreatography at 1.5 T using a deep learning-based noise-reduction approach: Comparison with the conventional respiratory-triggered technique
    Tajima, Taku
    Akai, Hiroyuki
    Sugawara, Haruto
    Yasaka, Koichiro
    Kunimatsu, Akira
    Yoshioka, Naoki
    Akahane, Masaaki
    Ohtomo, Kuni
    Abe, Osamu
    Kiryu, Shigeru
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 144
  • [6] Clinical feasibility of deep learning-accelerated single-shot turbo spin echo sequence with enhanced denoising for pancreas MRI at 3 Tesla
    Kim, Jeong Woo
    Park, Bit Na
    Nickel, Dominik
    Paek, Mun Young
    Lee, Chang Hee
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [7] Single-breath-hold thin-slice gadoxetic acid-enhanced hepatobiliary MR imaging using a newly developed three-dimensional fast spoiled gradient-echo sequence
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Takei, Naoyuki
    Wakayama, Tetsuya
    Sakane, Makoto
    Dia, Aliou Amadou
    Tsuboyama, Takahiro
    Nakamoto, Atsushi
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    MAGNETIC RESONANCE IMAGING, 2016, 34 (04) : 545 - 551
  • [8] Differentiation between hepatic cyst and hemangioma: Additive value of breath-hold, multisection fluid-attenuated inversion-recovery magnetic resonance imaging using half-Fourier acquisition single-shot turbo-spin-echo sequence
    Sasaki, K
    Ito, K
    Koike, S
    Fujita, T
    Okazaki, H
    Matsunaga, N
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) : 29 - 36
  • [9] Small hepatic lesions found on single-phase helical CT in patients with malignancy: Diagnostic capability of breath-hold, multisection fluid-attenuated inversion-recovery (FLAIR) MR imaging using a half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence
    Sasaki, Katsumi
    Ito, Katsuyoshi
    Fujita, Takeshi
    Shimizu, Ayame
    Yasui, Masayasu
    Hayashida, Minoru
    Tanabe, Masahiro
    Matsunaga, Naofumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 129 - 136