Thickness mapping of organic layers applied on sterling silver by means of X-ray fluorescence scanning

被引:5
|
作者
Porcinai, Simone [1 ]
Heginbotham, Arlen [2 ]
机构
[1] Opificio Pietre Dure MIBACT, Sci Lab, Viale F Strozzi 1, I-50129 Florence, Italy
[2] J Paul Getty Museum, Decorat Arts & Sculpture Conservat Dept, 1200 Getty Ctr Dr,Suite 1000, Los Angeles, CA 90049 USA
关键词
X-ray fluorescence; Thickness measurements; Mapping; Coating; Metal protection; K-ALPHA/K-BETA; COATINGS;
D O I
10.1016/j.sab.2021.106158
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The application of organic protective coatings is the most commonly used strategy to avoid tarnishing of silver artefacts. Non-invasive mapping of coating thickness is a key point to evaluate the consistency and completeness of coating application and to monitor protective effectiveness over time. This work is aimed at evaluating the feasibility of acquiring thickness maps of coated silver surfaces by means of X-ray fluorescence scanning. Experimental calibration curves were built by using organic films of known thickness made of several commonly used protective coatings, (Zapon nitrocellulose lacquer, and acrylic resins Paraloid B72 and Paraloid B44). X-ray fluorescence scans were performed on coated silver sterling coupons treated by brushing or spraying polymer solutions prepared with different solvents and concentrations. Thickness maps pointed out different average thickness values among selected polymers and highlighted that almost all the coatings were unevenly spread on the surface. Application by brush provided particularly uneven coatings and brush strokes were clearly distinguishable. The accuracy of thickness measurements was calculated by means of a semi-empirical approach, and results suggest that thickness can be predicted with an uncertainty of about +/- 5%.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Ag X-ray fluorescence on different thickness and concentration layers
    Brocchieri, J.
    Scialla, E.
    Ambrosino, F.
    Terrasi, F.
    Sabbarese, C.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2018, 41 (06):
  • [2] Quantitative thickness determination using x-ray fluorescence:: application to multiple layers
    Nygård, K
    Hämäläinen, K
    Manninen, S
    Jalas, P
    Ruottinen, JP
    X-RAY SPECTROMETRY, 2004, 33 (05) : 354 - 359
  • [3] Mapping with Macro X-ray Fluorescence Scanning of Raffaello's Portrait of Leo X
    Mazzinghi, Anna
    Ruberto, Chiara
    Giuntini, Lorenzo
    Mando, Pier Andrea
    Taccetti, Francesco
    Castelli, Lisa
    HERITAGE, 2022, 5 (04): : 3993 - 4005
  • [4] X-ray fluorescence-based methods to measure the thickness of protective organic coatings on ancient silver artefacts
    Porcinai, S.
    Ferretti, M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 149 : 184 - 189
  • [5] X-RAY FLUORESCENCE AS APPLIED TO CYRTOLITE
    NORTON, DA
    AMERICAN MINERALOGIST, 1957, 42 (7-8) : 492 - 505
  • [6] Nanoparticle characterization by means of scanning free grazing emission X-ray fluorescence
    Kayser, Yves
    Sa, Jacinto
    Szlachetko, Jakub
    NANOSCALE, 2015, 7 (20) : 9320 - 9330
  • [7] X-RAY MEASUREMENT OF THE THICKNESS OF SILVER PLATING
    GRAY, RB
    PHYSICAL REVIEW, 1946, 69 (1-2): : 49 - 49
  • [8] ON X-RAY FLUORESCENCE OF THIN LAYERS AND MULTILAYERS
    DAHL, H
    SCHULZ, G
    ZEITSCHRIFT FUR ANGEWANDTE PHYSIK, 1970, 29 (02): : 117 - &
  • [9] Application of Macro X-ray Fluorescence Fast Mapping to Thickness Estimation of Layered Pigments
    Zito, Riccardo
    Bonizzoni, Letizia
    Ludwig, Nicola
    SUSTAINABILITY, 2024, 16 (06)
  • [10] Comparison of X-ray fluorescence and optical fluorescence measured behind scattering layers as a basis for X-ray fluorescence endoscopy
    Beuthan, J
    Haschke, M
    Dressler, C
    Wacker, F
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (03): : 54 - 59