Flowrate Measurement of Air-Water Two-Phase Flow Using an Electrical Resistance Tomography Sensor and a Venturi meter

被引:0
|
作者
Meng, Zhenzhen [1 ]
Huang, Zhiyao [1 ]
Wang, Baoliang [1 ]
Ji, Haifeng [1 ]
Li, Haiqing [1 ]
机构
[1] Zhejiang Univ, Dept Control Sci & Engn, State Key Lab Ind Control Technol, Hangzhou 310003, Zhejiang, Peoples R China
关键词
two-phase flow; flowrate measurement; Venturi meter; electrical resistance tomography; SUPPORT VECTOR MACHINES; SHARP-EDGED ORIFICES; STEAM;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A flowrate measurement method for air-water two-phase flow is developed using an Electrical Resistance Tomography (ERT) sensor and a Venturi meter. With the conductance values measured by the ERT sensor, the real-time flow pattern is identified and the voidage is also calculated. The Butterworth correlation is applied to calculate the mass quality from the voidage value, and then six Venturi measurement correlations are introduced to predict the mass flowrate of two-phase flow. The flow, pattern classifier is constructed by using the Partial Least Square (PLS) method and the Least Squares Support Vector Machine (LS-SVM) classification method. The voidage measurement models are developed by using the PLS method and the LS-SVM regression method for different flow patterns. Experiment results verify that this measurement method is effective. The research work also shows that among the six Venturi measurement correlations the Collins correlation always performs the best for the flow condition in this work.
引用
收藏
页码:114 / 117
页数:4
相关论文
共 50 条
  • [1] Air-water two-phase flow measurement using a Venturi meter and an electrical resistance tomography sensor
    Meng, Zhenzhen
    Huang, Zhiyao
    Wang, Baoliang
    Ji, Haifeng
    Li, Haiqing
    Yan, Yong
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (03) : 268 - 276
  • [2] Horizontal Air-Water Two-Phase Flow Measurement Using an Electrical Impedance Probe and a Venturi Flow Meter
    Chiesa, G.
    Bertani, C.
    Falcone, N.
    Bersano, A.
    De Salve, M.
    Panella, B.
    36TH UIT HEAT TRANSFER CONFERENCE, 2019, 1224
  • [3] Two-phase flow rate measurement using a capacitive sensor and a Venturi meter
    Wrasse, Aluisio do N.
    Bertoldi, Dalton
    Morales, Rigoberto E. M.
    da Silva, Marco Jose
    2017 IEEE SENSORS, 2017, : 822 - 824
  • [4] Flowrate Measurement of Air-Water Two-Phase Flow with Double-cone Flowmeter
    Xu, Peng
    Xie, Dailiang
    Liu, Tiejun
    Xu, Zhipeng
    Liang, Xiaoyu
    2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2014, : 5812 - 5817
  • [5] Gas-oil two-phase flow measurement using an electrical capacitance tomography system and a Venturi meter
    Huang, ZY
    Xie, DL
    Zhang, HJ
    Li, HQ
    FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (2-3) : 177 - 182
  • [6] Characterization of air-water two-phase vertical flow by using electrical resistance imaging
    Wu, YX
    Li, H
    Wang, M
    Williams, RA
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2005, 83 (01): : 37 - 41
  • [7] OIL-WATER TWO-PHASE FLOW MEASUREMENT USING A VENTURI METER AND AN OVAL GEAR FLOW METER
    Li, Xia
    Huang, Zhiyao
    Meng, Zhenzhen
    Wang, Baoliang
    Li, Haiqing
    CHEMICAL ENGINEERING COMMUNICATIONS, 2010, 197 (02) : 223 - 231
  • [9] The parameters measurement of air-water two phase flow using the electrical resistance tomography (ERT) technique in a bubble column
    Jin, Haibo
    Lian, Yicheng
    Yang, Suohe
    He, Guangxiang
    Guo, Zhiwu
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 31 : 55 - 60
  • [10] Electrical Resistance Tomography Sensor for Highly Conductive Oil-Water Two-Phase Flow Measurement
    Jia, Jiabin
    Wang, Huarui
    Millington, David
    IEEE SENSORS JOURNAL, 2017, 17 (24) : 8224 - 8233