Design and simulation of a RF coil for a dedicated low-field MRI system

被引:0
|
作者
Asfour, A [1 ]
Maliverney, P [1 ]
Fournier, JM [1 ]
Raoof, K [1 ]
机构
[1] ENSIEG, LEG, F-38402 St Martin Dheres, France
关键词
MRI; RF coil; stray capacitance; variable step solenoid; field homogeneity;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Magnetic resonance imaging (MRI) has not yet been exploited for on-line quality control of agricultural and food products. For such applications, the RF coil is a major part of the system which must satisfy not only to usual MRI criterions but also to mechanical constraints (conveyors). The classical structure of an optimized solenoid coil as proposed by Hoult [1] is well adapted to on-line quality control of oranges. However, we show by calculations and measurements that even at our low working frequency (15 MHz) the stray capacitance of the optimized coil is greater than the tuning capacity. In order to obtain the required homogeneity we have carried out the design and numerical simulation of a variable step solenoid. We show that the obtained homogeneity is enhanced compared to a constant step solenoid.
引用
收藏
页码:187 / 190
页数:4
相关论文
共 50 条
  • [1] BREAST COIL DESIGN FOR LOW-FIELD MRI
    KOMU, M
    KORMANO, M
    MAGNETIC RESONANCE IN MEDICINE, 1992, 27 (01) : 165 - 170
  • [2] Dedicated low-field MRI in mice
    Choquet, P.
    Breton, E.
    Goetz, C.
    Marin, C.
    Constantinesco, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (17): : 5287 - 5299
  • [3] RF COIL FOR LOW-FIELD MRI COATED WITH HIGH-TEMPERATURE SUPERCONDUCTOR
    OKADA, H
    HASEGAWA, T
    VANHETEREN, JG
    KAUFMAN, L
    JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 107 (02): : 158 - 164
  • [4] Coil optimization for low-field MRI: a dedicated process for small animal preclinical studies
    Feuillet, T.
    Seurin, M-J
    Leveneur, O.
    Viguier, E.
    Beuf, O.
    LABORATORY ANIMALS, 2015, 49 (02) : 153 - 167
  • [5] Hand and wrist imaging using a low-field dedicated MRI system
    H. Bonél
    A. Frick
    H. Sittek
    A. Heuck
    M. Steinborn
    R. G. H. Baumeister
    M. Reiser
    Der Radiologe, 1997, 37 : 785 - 793
  • [6] Hand and wrist imaging using a low-field dedicated MRI system
    Bonel, H
    Frick, A
    Sittek, H
    Heuck, A
    Steinborn, M
    Baumeister, RGH
    Reiser, M
    RADIOLOGE, 1997, 37 (10): : 785 - 793
  • [7] An Exploration of a Phased-Array RF Coil for Very Low-Field Brain MRI
    Shen, Sheng
    Zhang, Yuxiang
    Kong, Xiaohan
    Yang, Lei
    Rosen, Matthew S.
    Xu, Zheng
    IEEE SENSORS JOURNAL, 2024, 24 (03) : 2905 - 2914
  • [8] Transverse low-field RF coils in MRI
    ClaasenVujcic, T
    Borsboom, HM
    Gaykema, HJG
    Mehlkopf, T
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) : 111 - 116
  • [9] MRI of the equine digit with a dedicated low-field magnet
    Choquet, P
    Sick, H
    Constantinesco, A
    VETERINARY RECORD, 2000, 146 (21) : 616 - 617
  • [10] EVALUATION OF KNEE OSTEOARTHRITIS WITH LOW-FIELD DEDICATED MRI
    Dong Dong
    Gu Guishan
    Huang Xu
    Cheng Shihuan
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 : 222 - 223