Amplitude Based Beat Detection for Atrial Fibrillation in Pacemaker

被引:0
|
作者
Lee, Seung Hwan [1 ]
Myoung, Hyoun Seok [1 ]
Kang, Chang Hoon [1 ]
Choi, Eue Keun [2 ]
Lee, Kyoung Joung [1 ]
机构
[1] Yonsei Univ, Dept Biomed Engn, Coll Hlth Sci, Wonju 26493, South Korea
[2] Seoul Natl Univ, Dept Internal Med, Coll Med, Seoul 03080, South Korea
关键词
IMPLANTABLE PACEMAKERS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bradycardia is defined as a sinus rhythm of less than 60 beats per minute and atrial tachyarrhythmia including atrial fibrillation (AF) is frequently associated with bradycardia. Pacemaker is the only effective treatment for symptomatic bradycardia and automatic mode switching (AMS) function is built in pacemaker to switch mode in the presence of atrial tachyarrhythmia. AMS algorithms consider appropriate mode switching in case of undersensing or oversensing and this consideration makes their onset time and resynchronization time late. Current pacemakers have onset time from 2.5 seconds to 26 seconds and resynchronization time from 3.4 seconds to 143 seconds according to manufacturers. In this work, we proposed beat detection algorithm based on amplitude difference between peak and trough for accurate extraction of atrial rate achieving faster mode switching. Evaluation of beat detection algorithm was conducted with six canine AF electrogram (EGM) data. Result showed 96.64% sensitivity, 95.5% positive predictive value in average. With this, transition from AF to normal sinus rhythm could be detected faster than existing AMS algorithms. In conclusion, proposed algorithm can efficiently detect beats in EGM during AF and from this, we can implement faster AMS algorithm.
引用
收藏
页码:2757 / 2759
页数:3
相关论文
共 50 条
  • [1] Atrial fibrillation reduces the atrial impedance amplitude during cardiac cycle: a novel detection algorithm to improve recognition of atrial fibrillation in pacemaker patients
    Schmidt, Boris
    Asbach, Stefan
    Schweika, Oliver
    Zehender, Manfred
    Bode, Christoph
    Faber, Thomas S.
    EUROPACE, 2007, 9 (09): : 812 - 816
  • [2] Deep learning model for atrial fibrillation detection based on single beat morphology
    Baalman, S. W. E.
    Schroevers, F. E.
    Oakley, A.
    Ramos, L. A.
    Lopes, R. R.
    Van der Stuijt, W.
    Brouwer, T. F.
    Knops, R. E.
    De Groot, J. R.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1404 - 1404
  • [3] Beat to Beat Wavelet Variability in Atrial Fibrillation
    Filos, D.
    Chouvarda, I.
    Dakos, G.
    Vassilikos, V.
    Maglaveras, N.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 953 - 956
  • [4] DETECTION OF ATRIAL, FIBRILLATION IN PACEMAKER CLINIC AND IMPROVEMENT ANTITHROMBOTIC THERAPY
    Salazar Ramirez, C.
    Cota Delgado, F.
    Carballo Ruiz, M.
    Ruiz del Fresno, L.
    Garcia Alcantara, A.
    De la Torre Prados, M. V.
    INTENSIVE CARE MEDICINE, 2013, 39 : S292 - S293
  • [5] Detection of occult atrial fibrillation by pacemaker interrogation in cryptogenic stroke
    Moubarak, Ghassan
    Tamazyan, Ruben
    Garcon, Philippe
    Join Lambert, Claire
    Bruandet, Marie
    Cazeau, Serge
    Zuber, Mathieu
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (03) : 261 - 265
  • [6] Detection of occult atrial fibrillation by pacemaker interrogation in cryptogenic stroke
    Ghassan Moubarak
    Ruben Tamazyan
    Philippe Garcon
    Claire Join Lambert
    Marie Bruandet
    Serge Cazeau
    Mathieu Zuber
    Journal of Interventional Cardiac Electrophysiology, 2014, 39 : 261 - 265
  • [7] PACEMAKER PERIODICITY IN ATRIAL FIBRILLATION
    BATTERSBY, EJ
    JOURNAL OF CLINICAL INVESTIGATION, 1964, 43 (06): : 1264 - &
  • [8] NERVES OF PACEMAKER IN ATRIAL FIBRILLATION
    ROSSI, L
    BRITISH MEDICAL JOURNAL, 1962, (5277): : 564 - &
  • [9] Atrial fibrillation in the pacemaker clinic
    McLellan, CS
    Abdollah, H
    Brennan, FJ
    Simpson, CS
    CANADIAN JOURNAL OF CARDIOLOGY, 2003, 19 (05) : 492 - 494
  • [10] PACEMAKER PERIODICITY IN ATRIAL FIBRILLATION
    BATTERSBY, EJ
    CIRCULATION RESEARCH, 1965, 17 (04) : 296 - +