Human Milk Analysis Using Mid-Infrared Spectroscopy

被引:26
|
作者
Groh-Wargo, Sharon [1 ,2 ]
Valentic, Jennifer [1 ]
Khaira, Sharmeel [1 ]
Super, Dennis M. [1 ]
Collin, Marc [1 ]
机构
[1] Case Western Reserve Univ, MetroHlth Med Ctr, Dept Pediat, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, MetroHlth Med Ctr, Dept Nutr, Cleveland, OH 44106 USA
关键词
neonates; enteral nutrition; human milk; newborn infant; INTENSIVE-CARE-UNIT; BREAST-MILK; PREMATURE-INFANTS; RAPID MEASUREMENT; PRETERM INFANTS; GERBER METHOD; FAT-CONTENT; RAW-MILK; MACRONUTRIENTS; PROTEIN;
D O I
10.1177/0884533615596508
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: The composition of human milk is known to vary with length of gestation, stage of lactation, and other factors. Human milk contains all nutrients required for infant health but requires fortification to meet the needs of low-birth-weight infants. Without a known nutrient profile of the mother's milk or donor milk fed to a baby, the composition of the fortified product is only an estimate. Human milk analysis has the potential to improve the nutrition care of high-risk newborns by increasing the information about human milk composition. Equipment to analyze human milk is available, and the technology is rapidly evolving. This pilot study compares mid-infrared (MIR) spectroscopy to reference laboratory milk analysis. Methods: After obtaining informed consent, we collected human milk samples from mothers of infants weighing <2 kg at birth. Duplicate samples were analyzed for macronutrients by MIR and by reference laboratory analysis including Kjeldahl for protein, Mojonnier for fat, and high-pressure liquid chromatography for lactose. Intraclass correlation coefficients, Bland-Altman scatter plots, and paired t tests were used to compare the two methods. Results: No significant differences were detected between the macronutrient content of human milk obtained by MIR vs reference laboratory analysis. Conclusions: MIR analysis appears to provide an accurate assessment of macronutrient content in expressed human milk from mothers of preterm infants. The small sample size of this study limits confidence in the results. Measurement of lactose is confounded by the presence of oligosaccharides. Human milk analysis is a potentially useful tool for establishing an individualized fortification plan.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 50 条
  • [1] Validation of mid-infrared spectroscopy for macronutrient analysis of human milk
    S Parat
    S Groh-Wargo
    S Merlino
    C Wijers
    D M Super
    [J]. Journal of Perinatology, 2017, 37 : 822 - 826
  • [2] Validation of mid-infrared spectroscopy for macronutrient analysis of human milk
    Parat, S.
    Groh-Wargo, S.
    Merlino, S.
    Wijers, C.
    Super, D. M.
    [J]. JOURNAL OF PERINATOLOGY, 2017, 37 (07) : 822 - 826
  • [3] Macronutrient analysis of preterm human milk using mid-infrared spectrophotometry
    Bulut, Ozgul
    Coban, Asuman
    Ince, Zeynep
    [J]. JOURNAL OF PERINATAL MEDICINE, 2019, 47 (07) : 785 - 791
  • [4] Creamatocrit Analysis of Human Milk Overestimates Fat and Energy Content When Compared to a Human Milk Analyzer Using Mid-infrared Spectroscopy
    O'Neill, Edward F.
    Radmacher, Paula G.
    Sparks, Blake
    Adamkin, David H.
    [J]. JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2013, 56 (05): : 569 - 572
  • [5] Prediction of coagulating and noncoagulating milk samples using mid-infrared spectroscopy
    De Marchi, M.
    Toffanin, V.
    Cassandro, M.
    Penasa, M.
    [J]. JOURNAL OF DAIRY SCIENCE, 2013, 96 (07) : 4707 - 4715
  • [6] Classifying the fertility of dairy cows using milk mid-infrared spectroscopy
    Ho, P. N.
    Bonfatti, V
    Luke, T. D. W.
    Pryce, J. E.
    [J]. JOURNAL OF DAIRY SCIENCE, 2019, 102 (11) : 10460 - 10470
  • [7] Multianalyte serum analysis using mid-infrared spectroscopy
    Shaw, RA
    Kotowich, S
    Leroux, M
    Mantsch, HH
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 624 - 632
  • [8] Adulteration Detection of Urea in Milk by Mid-Infrared Spectroscopy
    Yang Ren-jie
    Liu Rong
    Xu Ke-xin
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (09) : 2383 - 2385
  • [9] Identification and quantification of goat milk adulteration using mid-infrared spectroscopy and chemometrics
    Du, Chao
    Zhao, XueHan
    Chu, Chu
    Nan, LiangKang
    Ren, XiaoLi
    Yan, Lei
    Zhang, XiaoJian
    Zhang, ShuJun
    Teng, ZhanWei
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 324
  • [10] Prediction of protein composition of individual cow milk using mid-infrared spectroscopy
    De Marchi, Massimo
    Bonfatti, Valentina
    Cecchinato, Alessio
    Di Martino, Guido
    Carnier, Paolo
    [J]. ITALIAN JOURNAL OF ANIMAL SCIENCE, 2009, 8 : 399 - 401