An improved configuration for the reduction of EMG in electrode cuff recordings: A theoretical approach

被引:30
|
作者
Rahal, M
Winter, J
Taylor, J
Donaldson, N
机构
[1] UCL, Dept Elect & Elect Engn, London WC1E 7JE, England
[2] UCL, Dept Med Phys & Bioengn, London WC1E 7JE, England
关键词
ENG recording; nerve cuff electrodes; residual EMG; screened tripole; tripolar electrodes;
D O I
10.1109/10.867963
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A theoretical investigation of different electroneurogram recording techniques using electrode cuffs is presented. ii new; screened tripole arrangement is proposed with a higher inherent signal to interference ratio than the true tripole, which also allows the nulling of the residual electromyogram signal, The reduction in interference is small because the electrode impedance is large compared to the source resistance.
引用
收藏
页码:1281 / 1284
页数:4
相关论文
共 50 条
  • [1] Interference reduction in nerve cuff electrode recordings - A new approach
    Rahal, M
    Winter, J
    Taylor, J
    Donaldson, N
    ISCAS '99: PROCEEDINGS OF THE 1999 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 6: CIRCUITS ANALYSIS, DESIGN METHODS, AND APPLICATIONS, 1999, : 493 - 496
  • [2] Adaptive interference reduction in nerve cuff electrode recordings
    Triantis, I
    Rieger, R
    Taylor, J
    Donaldson, N
    ICECS 2001: 8TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-III, CONFERENCE PROCEEDINGS, 2001, : 669 - 672
  • [3] Improved nerve cuff electrode recordings with subthreshold anodic currents
    Sahin, M
    Durand, DM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (08) : 1044 - 1050
  • [4] On the spectrum of nerve cuff electrode recordings
    Struijk, JJ
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2006 - 2007
  • [5] Signal strength in Nerve Cuff Electrode recordings
    Andreasen, LNS
    Struijk, JJ
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 719 - 720
  • [6] Signal strength versus cuff length in nerve cuff electrode recordings
    Andreasen, LNS
    Struijk, JJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) : 1045 - 1050
  • [7] Long-term stability of EMG recordings using a wireless EMG electrode
    Skov-Madsen, Gitte
    Rijkhoff, Nico
    Vistisen, Bodil K.
    ISABEL: 2008 FIRST INTERNATIONAL SYMPOSIUM ON APPLIED SCIENCES IN BIOMEDICAL AND COMMMUNICATION TECHNOLOGIES, 2008, : 224 - +
  • [8] Fascicular selectivity in transverse stimulation with a nerve cuff electrode: A theoretical approach
    Deurloo, KEI
    Holsheimer, J
    Bergveld, P
    NEUROMODULATION, 2003, 6 (04): : 258 - 269
  • [9] Spiral nerve cuff electrode for recordings of respiratory output
    Sahin, M
    Haxhiu, MA
    Durand, DM
    Dreshaj, IA
    JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (01) : 317 - 322
  • [10] Adaptive approach for change detection in EMG recordings
    El Falou, W
    Khalil, M
    Duchêne, J
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 1875 - 1878