Measured Corneal Astigmatism Versus Pseudophakic Predicted Refractive Astigmatism in Cataract Surgery Candidates

被引:13
|
作者
Abulafia, Adi [1 ,6 ]
Barrett, Grahama D. [2 ,3 ]
Porat-Rein, Adi [1 ]
Tsessler, Maria [1 ]
Zadok, David [1 ]
Kan-Tor, Yoav [2 ,4 ]
Mourits, Maarten P. [5 ]
Lapid-Gortzak, Ruth [3 ,5 ]
机构
[1] Hebrew Univ Jerusalem, Dept Ophthalmol, Shaare Zedek Med Ctr, Jerusalem, Israel
[2] Univ Western Australia, Sir Charles Gairdner Hosp, Sir Charles Gairdner Hosp, Perth, WA, Australia
[3] Univ Western Australia, Lions Eye Inst, Perth, WA, Australia
[4] Hebrew Univ Jerusalem, Ctr Interdisciplinary Data Sci Res, Rachel & Selim Benin Sch Comp Sci & Engn, Edmond J Safra Campus Givat Ram, Jerusalem, Israel
[5] Univ Amsterdam, Dept Ophthalmol, Amsterdam UMC, AMC, Amsterdam, Netherlands
[6] Shaare Zedek Med Ctr, Dept Ophthalmol, Shmuel Bait St 12, IL-9103102 Jerusalem, Israel
关键词
INTRAOCULAR-LENS CALCULATIONS;
D O I
10.1016/j.ajo.2022.02.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare standard and total corneal astigmatism measurements to the predicted pseudopha-kic (nontoric) refractive astigmatism in candidates for cataract surgery. DESIGN: A retrospective, cross-sectional study. METHODS: A single-center analysis of consecutive eyes measured with a swept-source optical coherence tomography biometer at a large tertiary medical center between February 2018 and June 2020. Corneal astigmatism was calculated based on standard keratometry astigmatism (KA), total corneal astigmatism (TCA), and predicted refractive astigmatism (PRA) for a monofocal nontoric intraocular lens (IOL) implantation calculated by the Barrettoric calculator using the predicted posterior corneal astigmatism (PRA(Predicted-PCA) ) and the measured poste-rior corneal astigmatism (PRA(Measured-PCA) ) options. Separate analyses were performed for each eye. SETTING: Ophthalmology Department, Shaare Zedek Medical Center, Jerusalem, Israel. RESULTS: In total, 8152 eyes of 5320 patients (4221 right eyes [OD] and 3931 left eyes [OS], mean age 70.6 +/- 12.2 years, 54.2% females) were included in the study. The mean vector values (centroid) for KA, TCA, PRA(Predicted-PCA), and PRA(Measured-PCA) were 0.07 diopters [D] at 19.5 degrees, 0.27 D at 7.5 degrees, 0.44 D at 2.9 degrees, and 0.43 D at 179.3 degrees, respectively ( P < .01), for OD and 0.02 D at 150.3 degrees, 0.23 D at 169.7 degrees, 0.40 D at 179.4 degrees, and 0.42 D at 169.5 degrees, respectively ( P < .01), for OS. More than 73% of eyes had a PRA > 0.5 D. CONCLUSIONS: Standard and total corneal astigmatism measurements differ significantly from the PRA by the Barrett toric calculator. The PRA, rather than the KA or TCA, should be used as the reference guide for astigmatism correction with toric IOL implantation. (C) 2022 Elsevier Inc. All rights reserved.
引用
下载
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [1] Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery
    Maki Sano
    Takahiro Hiraoka
    Yuta Ueno
    Hideo Itagaki
    Tomohiro Ogami
    Tetsuro Oshika
    BMC Ophthalmology, 16
  • [2] Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery
    Sano, Maki
    Hiraoka, Takahiro
    Ueno, Yuta
    Itagaki, Hideo
    Ogami, Tomohiro
    Oshika, Tetsuro
    BMC OPHTHALMOLOGY, 2016, 16 : 1 - 9
  • [3] Comparison of corneal astigmatism with manifest refractive astigmatism in pseudophakic eyes
    Thaware, Omkar
    Tang, Maolong
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [4] Prevalence of corneal astigmatism in cataract surgery candidates in Bangkok, Thailand
    Lekhanont, Kaevalin
    Wuthisiri, Wadakarn
    Chatchaipun, Porntip
    Vongthongsri, Anun
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03): : 613 - 615
  • [5] Refractive, anterior corneal and internal astigmatism in the pseudophakic eye
    Bregnhoj, Jesper F.
    Mataji, Pourang
    Naeser, Kristian
    ACTA OPHTHALMOLOGICA, 2015, 93 (01) : 33 - 40
  • [6] Agreement Between Refractive and Corneal Astigmatism in Pseudophakic Eyes
    Tejedor, Jaime
    Guirao, Antonio
    CORNEA, 2013, 32 (06) : 783 - 790
  • [7] Biometry and corneal astigmatism in cataract surgery candidates from Southern China
    Cui, Ying
    Meng, Qianli
    Guo, Haike
    Zeng, Jin
    Zhang, Hongyang
    Zhang, Guanrong
    Huang, Yu
    Lan, Jianqing
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10): : 1661 - 1669
  • [8] Astigmatism measurements for cataract and refractive surgery
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2065 - 2065
  • [9] Prevalence of corneal astigmatism in cataract surgery candidates at a public hospital in Brazil
    Theiss, Mara Barreto
    Santhiago, Marcony R.
    Moraes Jr, Haroldo, V
    Gomes, Beatriz Fiuza
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2019, 82 (05) : 377 - 380
  • [10] CORNEAL ASTIGMATISM FOLLOWING CATARACT SURGERY
    ROWAN, PJ
    ANNALS OF OPHTHALMOLOGY, 1978, 10 (02): : 231 - 234