Evaluating the discriminatory power of EQ-5D, HUI2 and HUI3 in a US general population survey using Shannon's indices

被引:56
|
作者
Janssen, Mathieu F. Bas [1 ]
Birnie, Erwin [1 ]
Bonsel, Gouke J. [1 ]
机构
[1] Acad Med Ctr, Dept Social Med, NL-1100 DD Amsterdam, Netherlands
关键词
health status; methodology; psychometrics; population health; health-related quality-of-life;
D O I
10.1007/s11136-006-9160-6
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives To compare quantitatively the discriminatory power of the EQ-5D, HUI2 and HUI3 in terms of absolute and relative informativity, using Shannon's indices. Methods EQ-5D and HUI2/3 data completed by a sample of the general adult US population (N = 3,691) were used. Five dimensions allowed head-to-head comparison of informativity: Mobility/Ambulation; Anxiety/Depression/Emotion; Pain/Discomfort (EQ-5D; HUI2; HUI3); Self-Care (EQ-5D; HUI2); and Cognition (HUI2; HUI3). Shannon's index and Shannon's Evenness index were used to assess absolute and relative informativity, both by dimension and by instrument as a whole. Results Absolute informativity was highest for HUI3, with the largest differences in Pain/Discomfort and Cognition. Relative informativity was highest for EQ-5D, with the largest differences in Mobility/Ambulation and Anxiety/Depression/Emotion. Absolute informativity by instrument was consistently highest for HUI3 and lowest for EQ-5D, and relative informativity was highest for EQ-5D and lowest for HUI3. Discussion Performance in terms of absolute and relative informativity of the common dimensions of the three instruments varies over dimensions. Several dimensions are suboptimal: Pain/Discomfort (EQ-5D) seems too crude with only 3 levels, and the level descriptions of Ambulation (HUI3) and Self-Care (HUI2) could be improved. In absence of a formal measure, Shannon's indices provide useful measures for assessing discriminatory power of utility instruments.
引用
收藏
页码:895 / 904
页数:10
相关论文
共 33 条
  • [1] Evaluating the discriminatory power of EQ-5D, HUI2 and HUI3 in a US general population survey using Shannon’s indices
    Mathieu F. (Bas) Janssen
    Erwin Birnie
    Gouke J. Bonsel
    Quality of Life Research, 2007, 16 : 895 - 904
  • [2] Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
    Janneke P. C. Grutters
    Manuela A. Joore
    Frans van der Horst
    Hans Verschuure
    Wouter A. Dreschler
    Lucien J. C. Anteunis
    Quality of Life Research, 2007, 16 : 1439 - 1449
  • [3] Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
    Grutters, Janneke P. C.
    Joore, Manuela A.
    van der Horst, Frans
    Verschuure, Hans
    Dreschler, Wouter A.
    Anteunis, Lucien J. C.
    QUALITY OF LIFE RESEARCH, 2007, 16 (08) : 1439 - 1449
  • [4] COMPARISON OF EQ-5D AND HUI3 IN PATIENTS WITHTINNITUS
    Maes, I. H.
    Joore, M. A.
    Cima, R. F.
    Vlaeyen, J. W.
    Anteunis, L. J.
    VALUE IN HEALTH, 2008, 11 (06) : A347 - A347
  • [5] Relative Efficiency of the EQ-5D, HUI2, and HUI3 Index Scores in Measuring Health Burden of Chronic Medical Conditions in a Population Health Survey in the United States
    Luo, Nan
    Johnson, Jfrey A.
    Shaw, James W.
    Coons, Stephen Joel
    MEDICAL CARE, 2009, 47 (01) : 53 - 60
  • [6] EQ-5D and HUI2 Results from the Cure SMA Annual Community Update Survey
    Belter, Lisa
    Cruz, Rosangel
    Jarecki, Jill
    NEUROLOGY, 2021, 96 (15)
  • [7] A comparison of generic, indirect utility measures (the HUI2, HUI3, SF-6D, and the EQ-5D) and disease-specific instruments (the RAQoL and the HAQ) in rheumatoid arthritis
    Marra, CA
    Woolcott, JC
    Kopec, JA
    Shojania, K
    Offer, R
    Brazier, JE
    Esdaile, JM
    Anis, AH
    SOCIAL SCIENCE & MEDICINE, 2005, 60 (07) : 1571 - 1582
  • [8] Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
    A. Q. Summerfield
    G. R. Barton
    Quality of Life Research, 2019, 28 : 1145 - 1154
  • [9] Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
    Summerfield, A. Q.
    Barton, G. R.
    QUALITY OF LIFE RESEARCH, 2019, 28 (05) : 1145 - 1154
  • [10] USING HAQ TO ESTIMATE HUI3 AND EQ-5D UTILITY VALUES IN SPANISH RHEUMATOID ARTHRITIS PATIENTS
    Fernandez, I
    Varela, C.
    Layola, M.
    Ruiz, M. D.
    Navarro, F.
    VALUE IN HEALTH, 2008, 11 (06) : A551 - A551