Rowing ergometry for assessment of aerobic fitness in children

被引:4
|
作者
Gibson, PB [1 ]
Szimonisz, SM [1 ]
Rowland, TW [1 ]
机构
[1] Baystate Med Ctr, Dept Pediat, Springfield, MA 01199 USA
关键词
children; exercise testing; rowing; aerobic fitness;
D O I
10.1055/s-2000-8484
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Rowing ergometry has not been utilized as a modality for investigating aerobic fitness in children. This study evaluated the feasibility and reproducibility of measuring peak (V) over dot O-2 during progressive rowing on a Concept II ergometer in 16 healthy boys aged 9-12 years. All subjects were able to row effectively after minimal modeling and verbal instruction. Mean peak (V) over dot O-2 values on two trials were 42.9 (+/-7.9) and 41.6 (+/- 8.7) ml x kg(-1) x min(-1) (p>0.05). No significant differences were observed in mean peak heart rate (190+/-11 vs. 191 +/-12 bpm), peak ventilation (58.6+/-11.0 vs. 59.1+/-13.9 L x min(-1)), and RER (1.02+/-.07 vs. 1.02 +/-.05) on the two trials. The coefficient of variation of peak (V) over dot O-2 was 5.4%. These data suggest that rowing ergometry is an effective method of measuring aerobic fitness in preadolescent boys.
引用
收藏
页码:579 / 582
页数:4