HLA-B27 expression by flow cytometry: an analysis of 7 years quality assurance data

被引:3
|
作者
Macardle, PJ
McEvoy, R
Jovanovich, S
机构
[1] Flinders Med Ctr, Dept Immunol Allergy & Arthrit, Adelaide, SA 5047, Australia
[2] Royal Coll Pathol Australasia Qual Assurance Prog, Flinders Med Ctr, Adelaide, SA 5047, Australia
关键词
flow cytometry; HLA-B27; quality assurance;
D O I
10.1016/S0022-1759(00)00227-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The Royal College of Pathologists of Australasia Quality Assurance Programs Pty. Ltd. has been monitoring HLA-B27 assignment by flow cytometry for 7 years as part of the Immunology Program. Here we present data that demonstrates a gradual improvement in reports of false positive and negative results. Many participating laboratories demonstrate an ability to assign HLA-B27 status correctly by flow cytometric means. This ability appears to be independent of reagent and methodology. However a small number of laboratories produce consistently unacceptable results that suggest poor quality assurance practice. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [1] HLA-B27 SCREENING BY FLOW-CYTOMETRY
    LINGENFELTER, B
    FULLER, TC
    HARTUNG, L
    HUNTER, J
    WITTWER, C
    CYTOMETRY, 1995, 22 (02): : 146 - 149
  • [2] The flow cytometry as method for routine HLA-B27 typing
    Perez, A
    Rojano, J
    Castaneda, P
    HUMAN IMMUNOLOGY, 1996, 47 (1-2) : P233 - P233
  • [3] Automated routine HLA-B27 typing by flow cytometry
    Reynolds, WM
    Evans, PR
    Wilson, PJ
    Wong, WM
    Darke, C
    Smith, JL
    JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 197 (1-2) : 1 - 5
  • [4] Flow cytometry screening for HLA-B27 - A method for rapid sorting
    Lechevalier, D
    Nizou, JY
    Plotton, N
    Janus, G
    Meyran, M
    Eulry, F
    PRESSE MEDICALE, 1996, 25 (30): : 1388 - 1388
  • [5] Anti-HLA-B7/HLA-B44 strong cross immunoreactivity observed in flow cytometry HLA-B27 immunotyping
    Francois, Fabien
    Waeckel, Louis
    Berger, Anne-Emmanuelle
    Lambert, Claude
    CYTOMETRY PART A, 2024, 105 (05) : 376 - 381
  • [6] Optimisation of HLA-B27 testing by association of flow cytometry and DNA typing
    Bonnaud, G
    Aupetit, C
    Preux, PM
    Cogné, M
    Drouet, M
    CLINICAL RHEUMATOLOGY, 1999, 18 (01) : 23 - 27
  • [7] UTILIZATION OF COMMERCIAL ANTISERA AND FLOW-CYTOMETRY IN HLA-B27 TYPING
    ORR, K
    THOMSON, GTD
    ALFA, M
    CYTOMETRY, 1994, 18 (01): : 17 - 20
  • [8] HLA-B27 testing: A journey from flow cytometry to molecular subtyping
    Chheda, Pratiksha
    Warghade, Sandeep
    Mathias, Jyothi
    Dama, Tavisha
    Matkar, Sunmeet
    Shah, Nilesh
    Bendre, Rajesh
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (05)
  • [9] Comparison on flow cytometry and PCR-SSP in HLA-B27 typing
    Bonnaud, G
    Drouet, M
    HUMAN IMMUNOLOGY, 1996, 47 (1-2) : P402 - P402
  • [10] Optimisation of HLA-B27 Testing by Association of Flow Cytometry and DNA Typing
    G. Bonnaud
    C. Aupetit
    P. M. Preux
    M. Cogné
    M. Drouet
    Clinical Rheumatology, 1999, 18 : 23 - 27